Skip to product information
1 of 1

Live CZ2100C Double Pole MCB 10kA C Curve 100A | 2P Circuit Breaker

Live CZ2100C Double Pole MCB 10kA C Curve 100A | 2P Circuit Breaker

Regular price £12.57
Regular price Sale price £12.57
Sold out
Shipping calculated at checkout.

Custom printed panels are non-returnable.

Please upload the image, photo, or logo you would like printed on the LED panel.

Recommended image size:• 600 × 600 pixels or higher resolutionAccepted file formats:• JPG• PNG• PDF

AvailabilityLow stock: 89 left

Vendor: LIVE ELECTRIC
Category: Circuit Breaker

Shipping Policy

Once you receive your order confirmation email, your order will be processed within 2–3 business days (excluding weekends and public holidays).

Installation & Safety

Installation must be carried out by a qualified electrician.
Ensure power is switched off before installation.
Suitable for indoor use.

View full product details

The Live CZ2100C Double Pole MCB is a high-capacity industrial-grade miniature circuit breaker designed to provide reliable protection for very high-power single-phase circuits requiring simultaneous switching of both phase and neutral conductors with significant inductive loads. Rated at 100 Amps with a C-curve tripping characteristic, this 2-pole breaker safeguards both the phase and neutral conductors on AC systems up to 230/400V at 50/60Hz frequency. It features a powerful 10kA breaking capacity, making it suitable for installations with higher prospective short-circuit currents near main distribution points and transformers. The C-curve characteristic (5-10x In) provides excellent protection for circuits with substantial inductive loads while accommodating the massive inrush currents typical of large industrial equipment. With its robust construction and precision thermo-magnetic release, the CZ2100C ensures complete circuit isolation and equipment protection for demanding high-power applications requiring current ratings above the standard range with enhanced interrupting capacity.

Key Features of Live CZ2100C 100A 2P MCB

  • Complete Double Pole Protection: Simultaneously protects and switches both phase and neutral conductors, ensuring complete circuit isolation during fault conditions and maintenance.

  • High-Capacity 100A Rating: Provides protection for applications requiring 100A capacity, beyond the standard 63A maximum of conventional MCBs.

  • Enhanced 10kA Breaking Capacity: Powerful fault current interruption for installations with higher prospective short-circuit currents up to 10,000 amps.

  • C-Curve Characteristic: Trips instantaneously at 5-10 times rated current (500A to 1000A), specifically calibrated for high-power circuits with significant inductive loads.

  • Complete Isolation: Neutral pole disconnects simultaneously with phase, preventing floating neutral conditions and ensuring safety during maintenance.

  • Extended Current Range: Ideal for main distribution feeders, large industrial machinery, commercial building mains, and heavy-duty inductive loads.

  • Precision Thermo-Magnetic Release: Thermal bimetal strip for accurate overload protection and magnetic solenoid for instantaneous short-circuit response on both poles.

  • Superior Electrical Isolation: 4000V impulse withstand rating and 500V insulation voltage for protection against voltage transients.

  • Extended Operational Life: 8,000 electrical operations for long-term reliability.

  • Professional Installation: Standard 35mm DIN-rail mounting with IP20 finger-safe terminals.

Technical Specifications



Specification Details
Brand Live
Series CZ
Model Number CZ2100C
Device Type Miniature Circuit Breaker (MCB)
Pole Configuration 2 Pole (2P) - Switches Phase + Neutral
Current Rating (In) 100 Amperes
Trip Curve Type C Curve (5-10 × In)
Operational Voltage 230/400V AC
Rated Breaking Capacity 10kA (10000 Amps)
Frequency Range 50/60 Hertz
Insulation Rating (Ui) 500 Volts
Impulse Withstand (Uimp) 4000 Volts (1.2/50 µs)
Dielectric Test Voltage 2kV for 60 seconds
Protection Mechanism Thermo-magnetic (both poles)
Neutral Pole Protection Fully protected and switched
Operating Temperature -5°C to +40°C (daily average ≤35°C)
Calibration Reference 30°C
Storage Temperature -25°C to +70°C
Electrical Lifespan 8,000 cycles
Protection Class IP20
Terminal Capacity 35-50 mm² (suitable for 100A)
Mounting Type DIN Rail (35mm)
Standards BS IEC/EN 60898

Frequently Asked Questions (FAQs)

1. What specific applications require a 100A double pole C-Curve MCB with 10kA breaking capacity?
Main distribution feeders for large industrial facilities, high-power welding equipment (up to 23kW), large industrial machinery, and installations requiring complete phase and neutral isolation near transformers with high fault currents.

2. What is the advantage of 10kA breaking capacity at 100A C-Curve rating?
Provides enhanced protection in high-fault installations while handling massive inrush up to 1000A from large motors and transformers, ensuring both safety and operational reliability without nuisance tripping.

3. What is the power capacity of this 100A C-Curve double pole breaker?
Maximum load: 23kW at 230V. For motor applications, suitable for equipment up to 15-18kW depending on starting characteristics and duty cycle, with 10kA fault protection.

4. Why choose C-Curve over B-Curve for 100A double pole industrial applications?
C-Curve (5-10x In) handles starting currents up to 1000A where B-Curve (3-5x In) would trip at 500A, making C-Curve essential for industrial equipment with significant inrush currents.

5. What cable size is mandatory for 100A double pole circuits?
25mm² copper conductor minimum. 35mm² strongly recommended for longer runs, higher ambient temperatures, and to ensure proper termination capacity. Both phase and neutral conductors must be same size.