{"product_id":"versatile-protection-redefined-mini-rcbo-bi-directional-6ka-10a-type-a","title":"Versatile Protection Redefined: Mini RCBO Bi-Directional 6kA 10A Type A","description":"\u003cdiv class=\"ds-message _63c77b1\"\u003e\n\u003cdiv class=\"ds-markdown\"\u003e\n\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe Mini RCBO Bi-Directional 6kA 10A delivers a perfect balance of protection and installation flexibility, featuring true bi-directional operation that eliminates traditional supply orientation restrictions while providing robust 10-ampere protection for general purpose circuits. With a 10-ampere rated current and 1P+N (single pole + neutral) configuration in a compact 1-module design, this Mini RCBO is specifically engineered for protecting general purpose socket outlets, lighting circuits, office equipment, IT infrastructure, vending machines, small appliances, and any medium low-current application where installation flexibility and space efficiency are paramount. The device delivers 6kA rated short-circuit breaking capacity (Icn) with an exceptional 7.5kA service breaking capacity (Ics), ensuring reliable fault clearing under demanding conditions while maintaining full operational integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eManufactured in strict compliance with IEC\/EN61009-1 standards, this Type A Mini RCBO provides 30mA residual current protection capable of detecting both conventional sinusoidal AC leakage and pulsating DC leakage currents from modern electronic equipment. The revolutionary bi-directional design means the power supply can enter from either top or bottom terminals—unlike conventional RCBOs that require specific orientation—dramatically simplifying installation in crowded consumer units, retrofit applications, and distribution boards where traditional orientation would be impossible. With B-curve magnetic tripping characteristics (3-5x rated current = 30-50A trip range), pillar-type terminals accepting up to 25mm² cable, and impressive endurance ratings of 30,000 mechanical operations and 10,000 electrical operations, this Mini RCBO delivers uncompromising protection with unprecedented installation flexibility for 10A-rated circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRevolutionary Bi-Directional Design for General Purpose Circuits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe Mini RCBO Bi-Directional 10A breaks free from one of the most frustrating limitations of traditional RCBOs—fixed supply orientation. Conventional RCBOs require power to enter from the top (supply side) and connect to the bottom (load side), creating installation challenges in crowded consumer units, when retrofitting into existing boards with pre-configured busbars, or when working in tight spaces where cable routing is constrained. This innovative bi-directional Mini RCBO accepts power from either top or bottom terminals equally, allowing electricians to install the device in any orientation that suits the existing board configuration. This flexibility dramatically reduces installation time, eliminates the need for complex cable re-routing, and makes this RCBO the ideal choice for replacement installations where the original wiring orientation cannot be easily changed. The 1P+N configuration provides switching and protection on the line conductor while the neutral conductor is switched but not fused, offering complete circuit isolation while maintaining the compact 1-module footprint that saves valuable space in consumer units. The 10-ampere rating makes this bi-directional RCBO perfect for general purpose socket circuits, small appliance circuits, office power outlets, commercial display units, and any circuit requiring 10A protection with maximum installation flexibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFurthermore, the Type A residual current characteristic combined with the 10A B-curve rating makes this bi-directional Mini RCBO exceptionally versatile for modern general purpose circuits. Standard AC-type RCDs detect only smooth sinusoidal AC leakage currents, making them inadequate for circuits powering electronic equipment with switch-mode power supplies. This Type A Mini RCBO detects both AC sinusoidal and pulsating DC leakage currents, providing essential protection for modern 10A circuits powering computers, printers, monitors, LED lighting, phone chargers, vending machines, and small appliances with electronic controls. With 30mA sensitivity—the international standard for personnel protection against electric shock—this RCBO trips within milliseconds when leakage current exceeds 30mA. The mechanical endurance of 30,000 operations and electrical endurance of 10,000 cycles ensures long-term reliability for frequently accessed circuits. The bi-directional capability, combined with Type A protection and the practical 10A B-curve rating, makes this Mini RCBO the ideal solution for electricians seeking installation flexibility without compromising on safety or performance for general purpose power circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRevolutionary Bi-Directional Operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Accepts power supply from top or bottom terminals, eliminating traditional orientation restrictions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMini 1P+N Design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Compact 1-module width with line switching and neutral switching for complete circuit isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e10A Practical Rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Perfect for general purpose socket circuits, office equipment, and small appliances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e6kA Breaking Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Provides Icn=6kA and Ics=7.5kA (Ics higher than Icn for enhanced reliability)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType A Residual Current Detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Detects both sinusoidal AC and pulsating DC leakage currents for modern electronic loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e30mA Personnel Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Standard sensitivity for electric shock protection with millisecond trip response\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eB-Curve Magnetic Trip\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 3-5x rated current (30-50A) tripping characteristic ideal for socket and general purpose circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eExceptional Cycle Life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Rated for 30,000 mechanical operations and 10,000 electrical operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eGenerous Cable Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Pillar terminals accept up to 25mm² conductors for flexible installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIP20 Protection Rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Suitable for installation within consumer units, distribution boards, and enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Functions reliably from -5°C to +55°C, stores from -25°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Dielectric Strength\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 2500V insulation withstand for enhanced electrical safety\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandards Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Manufactured to IEC\/EN61009-1 for international acceptance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mini RCBO (Residual Current Breaker with Overcurrent) – Bi-Directional\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10 Amperes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Poles:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1P+N (1 module width, line + neutral switching)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230\/240VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eShort-Circuit Breaking Capacity (Icn):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 6kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eService Breaking Capacity (Ics):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 7.5kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMagnetic Tripping Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e B Curve (3-5x In = 30-50A trip range)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eResidual Tripping Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Type A (AC sinusoidal + pulsating DC detection)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Residual Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDirection of Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Bi-directional (top or bottom supply)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMechanical Endurance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Endurance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFrequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Strength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2500V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply Orientation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e UP (but accepts supply from either direction)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Pillar type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Cable Termination:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25mm²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eScrew Torque:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.5 Nm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection Grade:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -5°C to +55°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStorage Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -25°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandards Compliance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IEC\/EN61009-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. What makes bi-directional operation particularly valuable for 10A general purpose circuits?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eGeneral purpose 10A circuits are the most common circuits found in consumer units, often occupying multiple ways in the board. When retrofitting or replacing existing RCBOs, the original wiring orientation may not match conventional top-feed requirements. Bi-directional operation allows electricians to install this 10A Mini RCBO in any orientation that fits the existing busbar configuration or cable routing, eliminating the need to rewire multiple circuits. This is especially valuable when replacing older units where space is tight and cable lengths are fixed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. What is the difference between 1P+N (this RCBO) and 1P (standard RCBO)?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA standard 1P RCBO switches and protects only the line (live) conductor—the neutral passes through unprotected but is disconnected when the device trips. A 1P+N RCBO (like this Mini RCBO) switches both the line AND neutral conductors, providing complete isolation of the circuit. The neutral is switched but not fused (no overcurrent protection on neutral). This 1P+N design is preferred for socket circuits because it ensures the entire circuit is disconnected when tripped, eliminating any potential shock hazard from a neutral conductor that remains live due to shared neutral conditions in split-load boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. What applications are ideal for a 10A bi-directional Mini RCBO?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThis 10A B-curve bi-directional Mini RCBO is perfect for general purpose socket circuits (individual or small groups), office equipment power, IT and computer workstations, vending machines, small kitchen appliances, commercial display units, LED lighting circuits with moderate loads, circulation pumps, ventilation fans, and any general purpose circuit where 10A protection is needed with maximum installation flexibility. The bi-directional feature makes it especially valuable for retrofitting into older consumer units where traditional orientation would be difficult or impossible.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. Can I use this 10A bi-directional RCBO to protect a circuit with multiple 13A sockets?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eYes, a 10A RCBO can protect a circuit with multiple 13A BS1363 sockets, provided the total expected load does not exceed 10A. In practice, this limits the circuit to approximately 2-3 double sockets in a commercial environment or 3-4 double sockets in a domestic environment where loads are typically lower. For standard ring circuits with unlimited sockets, a 16A or 20A RCBO would be more appropriate. This 10A rating is best suited for dedicated socket circuits feeding specific equipment with known loads, such as an office workstation or a vending machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. What is the significance of Ics=7.5kA being higher than Icn=6kA on this bi-directional RCBO?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIcn (6kA) is the rated short-circuit breaking capacity—the maximum fault current this RCBO can interrupt once and remain safe for continued use. Ics (7.5kA) is the service short-circuit breaking capacity—the fault current the RCBO can interrupt and still remain fully functional for normal service. Having Ics higher than Icn is a premium reliability feature. It means if this RCBO clears a fault up to 7.5kA (25% higher than its rated capacity), it will continue operating correctly without needing replacement. This is particularly valuable for bi-directional RCBOs used in retrofit installations where the available fault current may not be precisely known or may vary with supply conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57290533994878,"sku":null,"price":10.81,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-50_d5b567e3-1182-4a34-a2f8-471adf31ada4.png?v=1776721155","url":"https:\/\/ssmelectric.co.uk\/products\/versatile-protection-redefined-mini-rcbo-bi-directional-6ka-10a-type-a","provider":"SSM ELECTRIC","version":"1.0","type":"link"}