{"product_id":"tpn-three-phase-distribution-boards-without-spd","title":"TPN Three Phase Distribution Boards (Without SPD)","description":"\u003ch2 data-end=\"667\" data-start=\"355\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eOverview\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"667\" data-start=\"355\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eExcel Group\u003c\/span\u003e\u003c\/span\u003e TPN Three Phase Distribution Boards are designed to deliver reliable and flexible power distribution for commercial and industrial electrical systems. Built for performance and durability, these boards offer a scalable solution for managing three-phase circuits efficiently.\u003c\/p\u003e\n\u003cp data-end=\"965\" data-start=\"669\"\u003eAvailable in configurations ranging from 4 to 24 usable ways, this range is engineered to suit a wide variety of installation requirements. With a strong steel construction and installer-friendly design, these boards provide a dependable foundation for safe and organised electrical distribution.\u003c\/p\u003e\n\u003chr data-end=\"970\" data-start=\"967\"\u003e\n\u003ch2 data-end=\"1010\" data-start=\"972\" data-section-id=\"105atsl\"\u003eWhy Choose a TPN Distribution Board\u003c\/h2\u003e\n\u003cp data-end=\"1282\" data-start=\"1012\"\u003eChoosing a TPN distribution board without SPD is ideal for installations where surge protection is managed separately or already integrated within the system. It provides a clean and flexible distribution solution while maintaining high safety and performance standards.\u003c\/p\u003e\n\u003cp data-end=\"1495\" data-start=\"1284\"\u003eWith its robust build quality and adaptable configuration options, this range is perfect for contractors and engineers who require a straightforward, durable, and easy-to-install three-phase distribution system.\u003c\/p\u003e\n\u003chr data-end=\"1500\" data-start=\"1497\"\u003e\n\u003ch2 data-end=\"1517\" data-start=\"1502\" data-section-id=\"1ma7m6t\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-end=\"1974\" data-start=\"1519\"\u003e\n\u003cli data-end=\"1568\" data-start=\"1519\" data-section-id=\"1ourr7n\"\u003eAvailable in 4, 8, 12, 16, and 24 usable ways\u003c\/li\u003e\n\u003cli data-end=\"1615\" data-start=\"1569\" data-section-id=\"dzk1dl\"\u003eHeavy-duty 1.2mm coated steel construction\u003c\/li\u003e\n\u003cli data-end=\"1663\" data-start=\"1616\" data-section-id=\"a7kz19\"\u003e125A main switch for reliable power control\u003c\/li\u003e\n\u003cli data-end=\"1713\" data-start=\"1664\" data-section-id=\"mtbx4h\"\u003eRemovable gland plates for easier cable entry\u003c\/li\u003e\n\u003cli data-end=\"1769\" data-start=\"1714\" data-section-id=\"1bx947f\"\u003eReversible door (left or right hinged installation)\u003c\/li\u003e\n\u003cli data-end=\"1824\" data-start=\"1770\" data-section-id=\"1h9v3h4\"\u003eFlexible configuration for industrial applications\u003c\/li\u003e\n\u003cli data-end=\"1872\" data-start=\"1825\" data-section-id=\"1ctvtp0\"\u003eDesigned for three-phase electrical systems\u003c\/li\u003e\n\u003cli data-end=\"1920\" data-start=\"1873\" data-section-id=\"1rrfgmm\"\u003eStrong, durable, and long-lasting enclosure\u003c\/li\u003e\n\u003cli data-end=\"1974\" data-start=\"1921\" data-section-id=\"1m2xaok\"\u003eEasy installation and maintenance-friendly design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1979\" data-start=\"1976\"\u003e\n\u003ch2 data-end=\"2008\" data-start=\"1981\" data-section-id=\"1cgu054\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-end=\"2454\" data-start=\"2010\"\u003e\n\u003cli data-end=\"2062\" data-start=\"2010\" data-section-id=\"16d06bu\"\u003eProduct Type: TPN Three Phase Distribution Board\u003c\/li\u003e\n\u003cli data-end=\"2111\" data-start=\"2063\" data-section-id=\"ax5n8\"\u003eBrand: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eExcel Group\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2140\" data-start=\"2112\" data-section-id=\"12lz5uj\"\u003eMain Switch Rating: 125A\u003c\/li\u003e\n\u003cli data-end=\"2175\" data-start=\"2141\" data-section-id=\"1ilzr1m\"\u003eSurge Protection: Not included\u003c\/li\u003e\n\u003cli data-end=\"2218\" data-start=\"2176\" data-section-id=\"168jpx9\"\u003eMaterial: 1.2mm coated steel enclosure\u003c\/li\u003e\n\u003cli data-end=\"2267\" data-start=\"2219\" data-section-id=\"17h2emt\"\u003eDoor Type: Reversible (left or right hinged)\u003c\/li\u003e\n\u003cli data-end=\"2307\" data-start=\"2268\" data-section-id=\"3kg5zt\"\u003eCable Entry: Removable gland plates\u003c\/li\u003e\n\u003cli data-end=\"2345\" data-start=\"2308\" data-section-id=\"1gcmkc2\"\u003eVoltage System: Three-phase (TPN)\u003c\/li\u003e\n\u003cli data-end=\"2397\" data-start=\"2346\" data-section-id=\"obbw11\"\u003eUsable Ways: 4, 8, 12, 16, 24 options available\u003c\/li\u003e\n\u003cli data-end=\"2454\" data-start=\"2398\" data-section-id=\"6eyopj\"\u003eApplication: Commercial and industrial installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2459\" data-start=\"2456\"\u003e\n\u003ch2 data-end=\"2468\" data-start=\"2461\" data-section-id=\"1xvwnkw\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-end=\"2616\" data-start=\"2470\"\u003e\u003cstrong data-end=\"2519\" data-start=\"2470\"\u003e1. What is a TPN distribution board used for?\u003c\/strong\u003e\u003cbr data-end=\"2522\" data-start=\"2519\"\u003eIt is used for distributing three-phase electrical power in commercial and industrial systems.\u003c\/p\u003e\n\u003cp data-end=\"2773\" data-start=\"2618\"\u003e\u003cstrong data-end=\"2666\" data-start=\"2618\"\u003e2. Does this board include surge protection?\u003c\/strong\u003e\u003cbr data-end=\"2669\" data-start=\"2666\"\u003eNo, this version is supplied without SPD for installations where surge protection is handled separately.\u003c\/p\u003e\n\u003cp data-end=\"2896\" data-start=\"2775\"\u003e\u003cstrong data-end=\"2823\" data-start=\"2775\"\u003e3. What material is the enclosure made from?\u003c\/strong\u003e\u003cbr data-end=\"2826\" data-start=\"2823\"\u003eIt is made from durable 1.2mm coated steel for strength and longevity.\u003c\/p\u003e\n\u003cp data-end=\"3028\" data-start=\"2898\"\u003e\u003cstrong data-end=\"2949\" data-start=\"2898\"\u003e4. Can the door be changed during installation?\u003c\/strong\u003e\u003cbr data-end=\"2952\" data-start=\"2949\"\u003eYes, the door is reversible and can be configured for left or right opening.\u003c\/p\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"3145\" data-start=\"3030\"\u003e\u003cstrong data-end=\"3076\" data-start=\"3030\"\u003e5. What sizes are available in this range?\u003c\/strong\u003e\u003cbr data-end=\"3079\" data-start=\"3076\"\u003eIt is available in 4, 8, 12, 16, and 24 usable way configurations.\u003c\/p\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289986703742,"sku":null,"price":312.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/tpn2.png?v=1776711392","url":"https:\/\/ssmelectric.co.uk\/products\/tpn-three-phase-distribution-boards-without-spd","provider":"SSM ELECTRIC","version":"1.0","type":"link"}