{"product_id":"maximum-capacity-installation-freedom-mini-rcbo-bi-directional-6ka-40a-type-a","title":"Maximum Capacity Installation Freedom: Mini RCBO Bi-Directional 6kA 40A Type A","description":"\u003cdiv class=\"ds-message _63c77b1\"\u003e\n\u003cdiv class=\"ds-markdown\"\u003e\n\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe Mini RCBO Bi-Directional 6kA 40A represents the maximum single-phase current rating available in this bi-directional RCBO series, delivering ultimate high-power protection with true bi-directional operation that eliminates traditional supply orientation restrictions. With a 40-ampere rated current and 1P+N (single pole + neutral) configuration in a compact 1-module design, this Mini RCBO is specifically engineered for protecting the most demanding single-phase applications including large electric range cookers (up to 9.2kW), commercial catering equipment including heavy-duty fryers and ovens, industrial machinery, electric vehicle fast chargers (up to 9.2kW), large air conditioning units, whole-house electric heating systems, sub-main distribution circuits, and any maximum-capacity single-phase application requiring 40A protection with ultimate installation flexibility. The device delivers 6kA rated short-circuit breaking capacity (Icn) with an exceptional 7.5kA service breaking capacity (Ics), ensuring reliable fault clearing under demanding conditions while maintaining full operational integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eManufactured in strict compliance with IEC\/EN61009-1 standards, this Type A Mini RCBO provides 30mA residual current protection capable of detecting both conventional sinusoidal AC leakage and pulsating DC leakage currents from modern electronic equipment. The revolutionary bi-directional design means the power supply can enter from either top or bottom terminals—unlike conventional RCBOs that require specific orientation—dramatically simplifying installation in crowded consumer units, retrofit applications, and distribution boards where traditional orientation would be impossible. With B-curve magnetic tripping characteristics (3-5x rated current = 120-200A trip range), pillar-type terminals accepting up to 25mm² cable, and impressive endurance ratings of 30,000 mechanical operations and 10,000 electrical operations, this Mini RCBO delivers uncompromising protection with unprecedented installation flexibility for the maximum 40A-rated single-phase circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eUltimate Bi-Directional Protection for Maximum-Capacity Single-Phase Circuits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe Mini RCBO Bi-Directional 40A represents the pinnacle of the bi-directional RCBO range, delivering the highest current rating available while maintaining the revolutionary orientation-free installation capability. Conventional RCBOs require power to enter from the top (supply side) and connect to the bottom (load side), creating installation challenges in crowded consumer units, when retrofitting into existing boards with pre-configured busbars, or when working in tight spaces where cable routing is constrained. This innovative bi-directional Mini RCBO accepts power from either top or bottom terminals equally, allowing electricians to install the device in any orientation that suits the existing board configuration. This flexibility dramatically reduces installation time, eliminates the need for complex cable re-routing, and makes this RCBO the ideal choice for replacement installations where the original wiring orientation cannot be easily changed. The 1P+N configuration provides switching and protection on the line conductor while the neutral conductor is switched but not fused, offering complete circuit isolation while maintaining the compact 1-module footprint that saves valuable space in consumer units. The 40-ampere maximum rating makes this bi-directional RCBO perfect for large electric range cookers and double ovens (up to 9.2kW total load), commercial catering equipment including heavy-duty fryers, chargrills, and combi-ovens, industrial machinery including large compressors and dust extractors, electric vehicle charging points (fast charging up to 9.2kW), large air conditioning units (up to approximately 9.2kW cooling capacity), whole-house electric heating systems or large electric boilers, sub-main distribution circuits feeding consumer units in outbuildings or workshops, and any maximum-capacity single-phase circuit requiring 40A protection with ultimate installation flexibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFurthermore, the Type A residual current characteristic combined with the maximum 40A B-curve rating makes this bi-directional Mini RCBO exceptionally versatile for modern high-power circuits. Standard AC-type RCDs detect only smooth sinusoidal AC leakage currents, making them inadequate for circuits powering electronic equipment with switch-mode power supplies. This Type A Mini RCBO detects both AC sinusoidal and pulsating DC leakage currents, providing essential protection for modern 40A circuits powering range cookers with digital controls and timers, commercial induction cooking equipment with high-frequency inverters, EV chargers with communication and control systems, inverter-driven commercial kitchen equipment, and variable speed drives for industrial machinery. With 30mA sensitivity—the international standard for personnel protection against electric shock—this RCBO trips within milliseconds when leakage current exceeds 30mA. The mechanical endurance of 30,000 operations and electrical endurance of 10,000 cycles ensures long-term reliability for frequently accessed circuits. The bi-directional capability at the maximum 40A rating, combined with Type A protection, makes this Mini RCBO the ultimate solution for electricians seeking installation flexibility without compromising on safety or performance for the most demanding single-phase circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRevolutionary Bi-Directional Operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Accepts power supply from top or bottom terminals, eliminating traditional orientation restrictions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum 40A Rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – The highest single-phase current rating in this bi-directional RCBO series for maximum-capacity applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMini 1P+N Design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Compact 1-module width with line switching and neutral switching for complete circuit isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e6kA Breaking Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Provides Icn=6kA and Ics=7.5kA (Ics higher than Icn for enhanced reliability)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType A Residual Current Detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Detects both sinusoidal AC and pulsating DC leakage currents for modern electronic loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e30mA Personnel Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Standard sensitivity for electric shock protection with millisecond trip response\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eB-Curve Magnetic Trip\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 3-5x rated current (120-200A) tripping characteristic ideal for maximum-capacity appliance circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eExceptional Cycle Life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Rated for 30,000 mechanical operations and 10,000 electrical operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eGenerous Cable Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Pillar terminals accept up to 25mm² conductors for flexible installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIP20 Protection Rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Suitable for installation within consumer units, distribution boards, and enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Functions reliably from -5°C to +55°C, stores from -25°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Dielectric Strength\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 2500V insulation withstand for enhanced electrical safety\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandards Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Manufactured to IEC\/EN61009-1 for international acceptance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mini RCBO (Residual Current Breaker with Overcurrent) – Bi-Directional, Maximum Rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 40 Amperes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Poles:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1P+N (1 module width, line + neutral switching)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230\/240VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eShort-Circuit Breaking Capacity (Icn):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 6kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eService Breaking Capacity (Ics):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 7.5kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMagnetic Tripping Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e B Curve (3-5x In = 120-200A trip range)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eResidual Tripping Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Type A (AC sinusoidal + pulsating DC detection)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Residual Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDirection of Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Bi-directional (top or bottom supply)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMechanical Endurance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Endurance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFrequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Strength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2500V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply Orientation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e UP (but accepts supply from either direction)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Pillar type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Cable Termination:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25mm²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eScrew Torque:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.5 Nm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection Grade:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -5°C to +55°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStorage Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -25°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandards Compliance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IEC\/EN61009-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. Why is 40A the maximum rating for this bi-directional Mini RCBO series?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIn single-phase electrical systems, 40A represents the practical maximum continuous current for RCBO protection before significant engineering challenges arise. At 40A and above, voltage drop becomes critical over relatively short cable runs (requiring 10mm² or 16mm² cable), and many domestic and commercial single-phase supplies are limited to 60A-80A total. For loads above 40A (exceeding 9.2kW), electrical regulations typically require three-phase supply (400V) to balance the load and reduce conductor sizes. This 40A Mini RCBO is the highest rating in the bi-directional series, with the bi-directional feature being especially valuable at this maximum rating where installation flexibility is most critical due to larger cable sizes and tighter space constraints.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. What applications require a 40A bi-directional Mini RCBO rather than a 32A?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA 40A RCBO is required when the connected load exceeds 32A (approximately 7.36kW) but is within 40A (9.2kW). Typical applications include large electric range cookers (9.2kW maximum, drawing exactly 40A at 230V), commercial catering equipment including heavy-duty fryers and ovens (typically 8kW-9.2kW), electric vehicle charging points (9.2kW fast charging), large air conditioning units (8kW-9.2kW cooling capacity), whole-house electric heating systems, and sub-main circuits feeding workshops or outbuildings. If your appliance rating exceeds 9.2kW (over 40A), you must upgrade to a three-phase supply or use a higher-rated MCCB. The bi-directional feature makes installation of these larger circuits much easier.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. Why is bi-directional operation particularly valuable for 40A maximum-capacity circuits?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e40A circuits typically use larger cables (10mm² or 16mm²) that are stiffer and less flexible than smaller cables, making them difficult to re-route or modify. When retrofitting or replacing existing 40A circuits, the original cable orientation may not match conventional top-feed RCBO requirements. Bi-directional operation allows you to install this 40A Mini RCBO in any orientation that matches the existing cable entry, saving hours of difficult rework and eliminating the need to modify stiff, large-gauge cables. This is especially valuable in commercial kitchens or industrial settings where 40A circuits are common and downtime is expensive.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. What is the difference between 1P+N (this RCBO) and 1P (standard RCBO) for a 40A circuit?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA standard 1P RCBO switches and protects only the line (live) conductor—the neutral passes through unprotected but is disconnected when the device trips. A 1P+N RCBO (like this Mini RCBO) switches both the line AND neutral conductors, providing complete isolation of the circuit. The neutral is switched but not fused (no overcurrent protection on neutral). This 1P+N design is strongly preferred for maximum-capacity 40A circuits powering large cookers, commercial equipment, and sub-mains because it ensures the entire circuit is fully disconnected when tripped, eliminating any potential shock hazard from a neutral conductor that remains live due to shared neutral conditions in split-load consumer units.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. What is the significance of Ics=7.5kA being higher than Icn=6kA on this maximum rating bi-directional RCBO?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIcn (6kA) is the rated short-circuit breaking capacity—the maximum fault current this RCBO can interrupt once and remain safe for continued use. Ics (7.5kA) is the service short-circuit breaking capacity—the fault current the RCBO can interrupt and still remain fully functional for normal service. Having Ics higher than Icn is a premium reliability feature, especially important at the maximum 40A rating. It means if this RCBO clears a fault up to 7.5kA (25% higher than its rated capacity), it will continue operating correctly without needing replacement. Most standard protective devices require replacement after clearing any fault at their Icn rating. This provides superior reliability and lower maintenance costs for expensive high-power equipment. The bi-directional design combined with this enhanced reliability makes this an outstanding choice for mission-critical maximum-capacity circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57290581213566,"sku":null,"price":10.81,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-50_bcce712c-eb5a-4861-98dd-b46e32d7164c.png?v=1776722187","url":"https:\/\/ssmelectric.co.uk\/products\/maximum-capacity-installation-freedom-mini-rcbo-bi-directional-6ka-40a-type-a","provider":"SSM ELECTRIC","version":"1.0","type":"link"}