{"product_id":"live-electrical-6a-type-a-mini-rcbo-30ma","title":"Live Electrical RS106B-030 Single Module 6A B Curve 6kA 30mA Type A Mini RCBO","description":"\u003cp\u003eThe Live Electrical RS106B-030 Mini RCBO provides reliable circuit protection in a compact single-module design. Combining overload, short-circuit, and 30mA earth leakage protection, this Type A RCBO ensures safe and compliant electrical installations for domestic and light commercial use.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"907\" data-end=\"953\"\u003eKEY FEATURES (based on manufacturer data)\u003c\/h2\u003e\n\u003cp data-start=\"954\" data-end=\"1260\"\u003e✔ Switching and isolation capability\u003cbr data-start=\"990\" data-end=\"993\"\u003e✔ Overload and short circuit protection\u003cbr data-start=\"1032\" data-end=\"1035\"\u003e✔ Protection against sinusoidal earth fault currents\u003cbr data-start=\"1087\" data-end=\"1090\"\u003e✔ Direct and indirect contact protection\u003cbr data-start=\"1130\" data-end=\"1133\"\u003e✔ Reduces fire risk from insulation faults\u003cbr data-start=\"1175\" data-end=\"1178\"\u003e✔ Compact single module design\u003cbr data-start=\"1208\" data-end=\"1211\"\u003e✔ Type A protection for modern electrical loads\u003c\/p\u003e\n\u003chr data-start=\"1262\" data-end=\"1265\"\u003e\n\u003ch2 data-start=\"1267\" data-end=\"1296\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cul data-start=\"1297\" data-end=\"1590\"\u003e\n\u003cli data-start=\"1297\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1299\" data-end=\"1318\"\u003eModel: RS106B-030\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1341\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1341\"\u003eCurrent Rating: 6A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1342\" data-end=\"1363\"\u003e\n\u003cp data-start=\"1344\" data-end=\"1363\"\u003eTripping Curve: B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1364\" data-end=\"1390\"\u003e\n\u003cp data-start=\"1366\" data-end=\"1390\"\u003eBreaking Capacity: 6kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1391\" data-end=\"1417\"\u003e\n\u003cp data-start=\"1393\" data-end=\"1417\"\u003eResidual Current: 30mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1418\" data-end=\"1441\"\u003e\n\u003cp data-start=\"1420\" data-end=\"1441\"\u003eDevice Type: Type A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1442\" data-end=\"1468\"\u003e\n\u003cp data-start=\"1444\" data-end=\"1468\"\u003eRated Voltage: 230V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1469\" data-end=\"1507\"\u003e\n\u003cp data-start=\"1471\" data-end=\"1507\"\u003eElectrical Endurance: 4,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1508\" data-end=\"1547\"\u003e\n\u003cp data-start=\"1510\" data-end=\"1547\"\u003eMechanical Endurance: 10,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1548\" data-end=\"1575\"\u003e\n\u003cp data-start=\"1550\" data-end=\"1575\"\u003eStandard: BS EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1576\" data-end=\"1590\"\u003e\n\u003cp data-start=\"1578\" data-end=\"1590\"\u003eModules: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1592\" data-end=\"1595\"\u003e\n\u003ch2 data-start=\"1597\" data-end=\"1639\"\u003e FAQs \u003c\/h2\u003e\n\u003ch3 data-start=\"1641\" data-end=\"1685\"\u003eWhat does a Type A RCBO protect against?\u003c\/h3\u003e\n\u003cp data-start=\"1686\" data-end=\"1812\"\u003eType A RCBOs detect AC and pulsating DC earth fault currents, making them suitable for modern appliances and electronic loads.\u003c\/p\u003e\n\u003ch3 data-start=\"1814\" data-end=\"1852\"\u003eWhere is a 6A RCBO typically used?\u003c\/h3\u003e\n\u003cp data-start=\"1853\" data-end=\"1935\"\u003eA 6A RCBO is commonly used for lighting circuits and low-load electrical circuits.\u003c\/p\u003e\n\u003ch3 data-start=\"1937\" data-end=\"1961\"\u003eWhat does 30mA mean?\u003c\/h3\u003e\n\u003cp data-start=\"1962\" data-end=\"2070\"\u003e30mA sensitivity provides protection against electric shock by disconnecting power when leakage is detected.\u003c\/p\u003e\n\u003ch3 data-start=\"2072\" data-end=\"2119\"\u003eIs this RCBO compliant with UK regulations?\u003c\/h3\u003e\n\u003cp data-start=\"2120\" data-end=\"2194\"\u003eYes, it complies with BS EN 61009-1 and is suitable for UK consumer units.\u003c\/p\u003e\n\u003ch3 data-start=\"2196\" data-end=\"2229\"\u003eCan this RCBO replace an MCB?\u003c\/h3\u003e\n\u003cp data-start=\"2230\" data-end=\"2294\"\u003eYes. An RCBO combines both RCD and MCB protection in one device.\u003c\/p\u003e","brand":"LIVE ELECTRIC","offers":[{"title":"Default Title","offer_id":56994324021630,"sku":"RS106B-030","price":9.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/Live_Electrical_6A_Type_A_Mini_RCBO_30mA_6kA.jpg?v=1772229886","url":"https:\/\/ssmelectric.co.uk\/products\/live-electrical-6a-type-a-mini-rcbo-30ma","provider":"SSM ELECTRIC","version":"1.0","type":"link"}