{"product_id":"live-dcm463c-4-pole-dc-mcb-6ka-c-curve-63a-4p-dc-circuit-breaker","title":"Live DCM463C 4 Pole DC MCB 6kA C Curve 63A | 4P DC Circuit Breaker","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLive DCM463C 4 Pole DC MCB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the highest-capacity specialized multi-pole direct current miniature circuit breaker in the DCM series, engineered to provide comprehensive protection for complex DC electrical circuits requiring simultaneous switching of multiple conductors at absolute maximum power levels. Rated at 63 Amps with a C-curve tripping characteristic, this 4-pole breaker represents the pinnacle of the DCM series, safeguarding DC circuits in applications such as ultra-scale industrial bipolar solar photovoltaic systems, massive DC distribution networks, and critical infrastructure telecommunications. It features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e6kA breaking capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e suitable for the most demanding DC installations. The C-curve characteristic (5-10x In) provides excellent protection for DC circuits while accommodating the characteristics of the highest-power DC sources. With its robust construction and precision thermo-magnetic release, the DCM463C ensures complete circuit isolation and equipment protection for the most complex ultra-scale renewable energy and massive DC applications requiring multi-pole switching at maximum current ratings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features of Live DCM463C 63A 4P DC MCB\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum-Capacity 4-Pole DC Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Highest rating in the DCM series for the most demanding DC applications requiring multi-pole switching.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSpecialized DC Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engineered specifically for direct current applications, ensuring reliable arc extinction and protection in DC circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4-Pole Switching:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Simultaneously protects and switches multiple conductors, ensuring complete circuit isolation in bipolar or multi-conductor DC systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e6kA DC Breaking Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Reliable fault current interruption for the most demanding DC installations including ultra-scale industrial bipolar solar PV and massive DC systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eC-Curve Characteristic:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Trips instantaneously at 5-10 times rated current (315A to 630A), specifically calibrated for DC circuits with moderate inrush characteristics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum-Capacity 63A DC Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ideal for ultra-scale industrial bipolar solar PV strings, massive DC distribution networks, critical telecom infrastructure, and complex high-power DC applications at maximum capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eUltra-Scale Focus:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Perfect for ultra-scale bipolar solar farms, positive\/negative\/earth switching, massive DC power distribution, and telecommunications hub networks at peak power levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePrecision Thermo-Magnetic Release:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Thermal bimetal strip for accurate overload protection and magnetic solenoid for instantaneous short-circuit response on all four poles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSuperior Arc Extinction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Specialized DC arc quenching technology ensures safe interruption of direct current without sustained arcing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eExtended Operational Life:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 8,000 electrical operations for long-term reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProfessional Installation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Standard 35mm DIN-rail mounting with IP20 finger-safe terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCM463C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Miniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePole Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Pole (4P)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCurrent Rating (In)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e63 Amperes \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e(Maximum series rating)\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTrip Curve Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eC Curve (5-10 × In)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRated Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC (consult rating chart for bipolar configurations)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRated Breaking Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e6kA (6000 Amps) DC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInsulation Rating (Ui)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 Volts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eImpulse Withstand (Uimp)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4000 Volts (1.2\/50 µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Test Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2kV for 60 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProtection Mechanism\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermo-magnetic (all poles)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-5°C to +40°C (daily average ≤35°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCalibration Reference\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Lifespan\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProtection Class\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16mm² (35-50mm² requires external termination)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (35mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBS IEC\/EN 60898 (DC applications)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions (FAQs)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. What are the primary ultra-scale applications for the DCM463C 4-pole 63A DC MCB?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eUltra-scale bipolar solar farms, massive DC power distribution centers, telecommunications hub infrastructure, data center main DC distribution, and heavy industrial DC control systems requiring absolute maximum capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. How does 63A 4-pole protection benefit ultra-scale bipolar solar installations?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIdeal for protecting the absolute largest ultra-scale bipolar solar arrays, typically supporting systems up to approximately 1500-1700W per circuit, ensuring complete simultaneous disconnection of all poles for maximum system safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. What is the advantage of 63A rating as the DCM series maximum for 4-pole applications?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eProvides the absolute highest capacity available in the DCM series, essential for the largest-scale solar farms, most extensive telecom infrastructure, or applications where 50A circuits would be insufficient.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. What are the critical cable considerations for 63A 4-pole DC circuits at maximum capacity?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e16mm² copper conductor MINIMUM per pole - this matches the maximum terminal capacity. For any run over 10m, external termination with 35mm² or 50mm² is MANDATORY. All four conductors must be identical size.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. Why is 63A the absolute maximum for 4-pole DC MCBs in the DCM series?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAt 63A, 16mm² cable is at its absolute ampacity limit. Higher currents would cause dangerous overheating. For applications requiring \u0026gt;63A with 4-pole switching, DC MCCBs are the necessary solution.\u003c\/span\u003e\u003c\/p\u003e","brand":"LIVE ELECTRIC","offers":[{"title":"Default Title","offer_id":57048054989182,"sku":null,"price":15.39,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/DCM406C_811ed72e-1197-4af1-854d-ce391e1cdb5b.webp?v=1773001822","url":"https:\/\/ssmelectric.co.uk\/products\/live-dcm463c-4-pole-dc-mcb-6ka-c-curve-63a-4p-dc-circuit-breaker","provider":"SSM ELECTRIC","version":"1.0","type":"link"}