{"product_id":"live-cb206b-double-pole-mcb-10ka-b-curve-6a-2p-circuit-breaker","title":"Live CB206B Double Pole MCB 10kA B Curve 6A | 2P Circuit Breaker","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLive CB206B Double Pole MCB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a precision-engineered miniature circuit breaker designed to provide comprehensive protection for single-phase circuits requiring simultaneous switching of both phase and neutral conductors. Rated at 6 Amps with a B-curve tripping characteristic, this 2-pole breaker safeguards both the phase and neutral conductors on AC systems up to 230\/400V at 50\/60Hz frequency. It features a powerful \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10kA breaking capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it suitable for installations with higher prospective short-circuit currents. The B-curve characteristic (3-5x In) provides fast response to faults while accommodating minimal inrush currents typical of sensitive circuits. With its robust construction and precision thermo-magnetic release, the CB206B ensures complete circuit isolation and equipment protection for residential, commercial, and industrial applications requiring double pole switching.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features of Live CB206B 6A 2P MCB\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComplete Double Pole Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Simultaneously protects and switches both phase and neutral conductors, ensuring complete circuit isolation during fault conditions and maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh 10kA Breaking Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Powerful fault current interruption for installations with high prospective short-circuit currents up to 10,000 amps.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eB-Curve Characteristic:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Trips instantaneously at 3-5 times rated current (18A to 30A), specifically calibrated for sensitive circuits with minimal inrush.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePrecision 6A Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ideal for lighting circuits, control systems, PLC power supplies, and sensitive electronic equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComplete Isolation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Neutral pole disconnects simultaneously with phase, preventing floating neutral conditions and ensuring safety during maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Application Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Suitable for residential, commercial, and light industrial installations requiring double pole protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePrecision Thermo-Magnetic Release:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Thermal bimetal strip for accurate overload protection and magnetic solenoid for instantaneous short-circuit response on both poles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSuperior Electrical Isolation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4000V impulse withstand rating and 500V insulation voltage for protection against voltage transients.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eExtended Operational Life:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 8,000 electrical operations for long-term reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProfessional Installation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Standard 35mm DIN-rail mounting with IP20 finger-safe terminals and 16mm² wiring capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCB206B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePole Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Pole (2P) - Switches Phase + Neutral\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCurrent Rating (In)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Amperes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTrip Curve Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eB Curve (3-5 × In)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperational Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230\/400V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRated Breaking Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e10kA (10000 Amps)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hertz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInsulation Rating (Ui)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 Volts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eImpulse Withstand (Uimp)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4000 Volts (1.2\/50 µs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Test Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2kV for 60 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProtection Mechanism\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermo-magnetic (both poles)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNeutral Pole Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully protected and switched\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-5°C to +40°C (daily average ≤35°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCalibration Reference\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Lifespan\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProtection Class\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 16 mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (35mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBS IEC\/EN 60898\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions (FAQs)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. What specific applications require a 6A double pole MCB with B-Curve?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLighting circuits in bathrooms and outdoor areas (safety isolation), control circuit transformers, PLC power supplies, small appliance circuits requiring neutral switching, and circuits where complete isolation is mandated by regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. Why choose double pole over single pole for 6A lighting circuits?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDouble pole provides complete isolation of both phase and neutral, essential for safety in wet locations (bathrooms, kitchens), for equipment requiring total disconnection, and compliance with local electrical codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. What is the power capacity of this 6A double pole breaker?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMaximum resistive load: 1.38kW at 230V. Continuous load (80% rule): 1.1kW. Suitable for approximately 30-40 LED downlights (30W each) or control transformers up to 1kVA.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. Can this breaker be used for lighting circuits in bathrooms?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eYes, it's ideal for bathroom lighting circuits where double pole isolation is often required by electrical regulations to ensure both phase and neutral are disconnected for safety in wet environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. What cable size is recommended for 6A double pole circuits?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1.5mm² copper conductor minimum. 2.5mm² recommended for mechanical robustness. Terminals accept up to 16mm² for installation flexibility. Both phase and neutral conductors must be same size.\u003c\/span\u003e\u003c\/p\u003e","brand":"LIVE ELECTRIC","offers":[{"title":"Default Title","offer_id":57032324809086,"sku":null,"price":5.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/CB206B.webp?v=1772731668","url":"https:\/\/ssmelectric.co.uk\/products\/live-cb206b-double-pole-mcb-10ka-b-curve-6a-2p-circuit-breaker","provider":"SSM ELECTRIC","version":"1.0","type":"link"}