{"product_id":"heavy-duty-protection-6ka-50a-miniature-circuit-breaker","title":"Heavy-Duty Protection: 6kA 50A Miniature Circuit Breaker","description":"\u003cdiv class=\"ds-message _63c77b1\"\u003e\n\u003cdiv class=\"ds-markdown\"\u003e\n\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe 6kA 50A Miniature Circuit Breaker represents the upper tier of residential and light commercial protection devices, engineered specifically for circuits that demand high continuous current capacity. With a 50-ampere rating, this MCB is the definitive choice for the most demanding electrical applications including large industrial machinery, commercial kitchen suites, three-phase workshop equipment, heavy-duty HVAC systems, electric vehicle fast chargers, and sub-main distribution circuits feeding multiple downstream loads. The robust 6kA breaking capacity ensures reliable interruption of severe short-circuit faults up to 6,000 amperes, providing critical protection for both personnel and expensive equipment while maintaining the structural integrity of the breaker itself.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eManufactured to meet rigorous international safety standards, this 50A MCB fully complies with IEC60898-1 and carries both CE and UKCA certifications, ensuring legal compliance for installations across the United Kingdom and European markets. The sophisticated thermal magnetic trip mechanism delivers two complementary layers of protection: the thermal bimetal element responds to prolonged overload conditions by accurately mimicking cable heating curves, while the electromagnetic coil reacts within milliseconds to short-circuit events. With support for 1, 2, 3, or 4-pole configurations, 50\/60Hz frequency operation, and standard 35mm DIN rail mounting, this circuit breaker delivers uncompromising professional-grade protection for any high-demand electrical installation requiring dependable overcurrent safeguarding at higher amperages.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSuperior Performance for High-Demand Electrical Systems\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSelecting a 50A rated MCB is essential when standard 40A or 32A protection would be insufficient for your equipment or circuit demands. This higher current rating makes the breaker perfectly suited for dedicated circuits powering industrial motors up to 18kW (three-phase), large commercial ovens and catering equipment, workshop machinery including compressors and welders, electric vehicle charging stations requiring 11kW or higher output, and sub-main distribution feeders supplying multiple consumer units or lighting distribution boards. The 6kA breaking capacity provides a substantial safety margin above typical commercial fault current levels, ensuring the breaker will safely clear even severe short-circuit events without welding contacts, generating dangerous arc flash, or rupturing its insulated housing. Unlike fuses that require complete replacement after every fault event, this resettable MCB can be simply switched back on after identifying and resolving the underlying issue, dramatically reducing downtime and ongoing maintenance costs for commercial operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFurthermore, the thermal magnetic trip mechanism offers two distinct layers of protection that work in perfect harmony. The thermal element uses a precision-calibrated bimetal strip that bends gradually under sustained overcurrent, accurately mimicking the heat buildup in your wiring insulation and tripping only when truly dangerous temperature thresholds are reached—preventing nuisance tripping while ensuring genuine protection. The magnetic element operates nearly instantaneously during short-circuit conditions, limiting let-through energy to less than 1 millisecond and protecting sensitive downstream electronics and VFD drives from damage. With multiple trip curve options (B, C, and D curves available), you can precisely match the breaker's response characteristics to your specific load type—whether that is purely resistive heating elements, motor-driven equipment with moderate startup surges, or transformer-coupled devices with extreme inrush currents. This level of customization, combined with UKCA and CE certification, makes this 6kA 50A MCB the professional-grade choice for any electrical installation requiring dependable, code-compliant overcurrent protection for higher-amperage, mission-critical circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e50 Ampere Rated Current\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Engineered for heavy-duty industrial machinery, large commercial equipment, and high-demand circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e6kA Breaking Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Safely interrupts short-circuit currents up to 6,000 amperes for comprehensive fault protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eThermal Magnetic Trip Mechanism\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Combines precise bimetal thermal overload protection with ultra-fast electromagnetic short-circuit interruption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDual Certification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Fully compliant with IEC60898-1 standards and certified CE and UKCA for regulatory compliance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVersatile Pole Configurations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Available in 1P, 2P, 3P, and 4P options to suit single-phase and three-phase systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eContact Status Indication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Clear visual indicator window shows red for closed (ON) and green for open (OFF\/tripped) contacts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDIN Rail Mounting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Standard 35mm rail design enables quick, tool-friendly installation in consumer units and distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eExceptional Cycle Life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Rated for 10,000 electrical operations and 20,000 mechanical operations for long-term durability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Temperature Tolerance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Operates reliably from -35°C to +70°C for various environmental conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMultiple Trip Curves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Available in B, C, or D characteristics to match specific motor, lighting, or transformer loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Wiring Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Accepts up to 25mm² conductors for minimal voltage drop on long high-current circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Miniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50 Amperes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eBreaking Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 6kA (Ics \u0026amp; Icn – both ratings equal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Poles:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1P, 2P, 3P, 4P (selectable based on application)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Frequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFrame Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 63A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e AC240V (1P) \/ AC415V (multi-pole)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Insulation Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 690V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Impulse Withstand Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4kV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTrip Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e B, C, D Curves available\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTrip Form:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Thermal magnetic trip\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePollution Level:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Life:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMechanical Life:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 20,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection Grade:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStorage Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -35°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation Site Altitude:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ≤2000m\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fixed with screw\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Wiring Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25mm²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Limit Torque:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.5 Nm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation Category:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Class II, III\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation Method:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 35mm standard DIN rail\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIncoming Method:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Upper or lower terminals (bidirectional)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandards Compliance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IEC60898-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCertifications:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e CE, UKCA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. What applications require a 50A MCB instead of a lower rating like 40A or 32A?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA 50A MCB is required when continuous circuit load exceeds 40A. Typical applications include 11kW electric vehicle charging stations (drawing approximately 45A), industrial motors up to 18kW (three-phase), large commercial ovens and cooking suites, workshop compressors and welders, electric boilers, and sub-main feeders supplying multiple distribution boards. Always calculate your actual continuous load before selecting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. What is the minimum cable size required for a 50A circuit protected by this MCB?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eFor a 50A circuit, the minimum recommended cable size is 10mm² for standard PVC-insulated copper conductors in open air or conduit. For longer runs exceeding 30 metres, or for cables installed in thermal insulation, 16mm² is often required to prevent excessive voltage drop and overheating. For three-phase 50A circuits, 6mm² may suffice for short runs, but 10mm² is strongly recommended. Always consult the latest IET Wiring Regulations (BS 7671) for specific installation methods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. Can I use this 50A MCB for a 50A continuous load like an electric vehicle charger?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eYes, but with important considerations. For continuous loads operating for 3+ hours (EV chargers, electric heating), regulations require derating to 80% of rated current. For a 50A MCB, this means the maximum continuous load should not exceed 40A. For true 50A continuous loads (11.5kW at 230V), you would need a 63A MCB. For EV charging at 50A, upgrade to the 63A version of this MCB series.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. What is the difference between Ics and Icn, and why are they both 6kA on this breaker?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIcn (Rated Short-Circuit Breaking Capacity) is the fault current the MCB can interrupt once and still function afterwards. Ics (Service Short-Circuit Breaking Capacity) is the fault current the MCB can interrupt repeatedly and still operate normally. On this breaker, both ratings are equal at 6kA, which is excellent – it means after clearing a maximum fault, the breaker remains fully operational rather than needing replacement, unlike many budget breakers where Ics is only 50-75% of Icn.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. How do I correctly select between B, C, and D curve for my 50A application?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSelect \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eB-curve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (3-5x 50A = 150-250A) for purely resistive loads like water heaters, ovens, and electric furnaces. Select \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eC-curve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (5-10x 50A = 250-500A) for general motor loads, lighting circuits with ballasts, HVAC equipment, and workshop machinery – this is the most common choice for 50A industrial applications. Select \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eD-curve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (10-20x 50A = 500-1000A) for high-inrush equipment like large transformers, X-ray machines, welding equipment, and motors with very high starting currents (cranes, lifts, large compressors).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57290107257214,"sku":null,"price":1.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/MCB3-3_d64f1b26-3791-4dd4-995c-1b05f930c9e2.png?v=1776713821","url":"https:\/\/ssmelectric.co.uk\/products\/heavy-duty-protection-6ka-50a-miniature-circuit-breaker","provider":"SSM ELECTRIC","version":"1.0","type":"link"}