{"product_id":"advanced-dual-protection-6ka-20a-rcbo-with-type-a-30ma-safety","title":"Advanced Dual Protection: 6kA 20A RCBO with Type A 30mA Safety","description":"\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe 6kA 20A RCBO (Residual Current Breaker with Overcurrent) delivers complete electrical safety by integrating both overcurrent protection and residual current detection into a single, space-saving 1-module unit. With a 20-ampere rated current, this RCBO is perfectly suited for protecting higher-capacity final circuits including dedicated appliance outlets for large kitchen equipment (4.6kW maximum at 230V), commercial catering appliances, workshop machinery, electric water heaters, immersion heaters, small commercial ovens, air conditioning units, and general purpose power circuits requiring higher current capacity than standard 16A protection. The device delivers 6kA rated short-circuit breaking capacity (Icn) with an exceptional 7.5kA service breaking capacity (Ics), ensuring reliable fault clearing under demanding conditions while maintaining full operational integrity for continued service after fault interruption—a premium reliability feature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eManufactured in strict compliance with IEC\/EN61009-1 standards, this Type A RCBO provides 30mA residual current protection specifically engineered to detect both conventional sinusoidal AC leakage and the pulsating DC leakage currents generated by modern electronic equipment. The Type A characteristic offers superior protection compared to basic AC-type RCDs, making it essential for circuits powering modern appliances with electronic controls, switch-mode power supplies, inverters, and variable speed drives. With B-curve magnetic tripping characteristics (3-5x rated current = 60-100A trip range), this RCBO is perfectly calibrated for higher-power circuits where moderate inrush currents from motors, compressors, or capacitive loads must be accommodated without nuisance tripping. Operating on 230\/240VAC single-phase systems at 50\/60Hz, featuring pillar-type terminals accepting up to 25mm² cable, and rated for 30,000 mechanical operations, this 20A RCBO represents the ideal protection solution for demanding residential circuits, commercial power outlets, and light industrial applications requiring robust integrated electrical safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRobust Protection for Higher-Capacity Power Circuits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe 20A RCBO serves the important middle ground between standard 16A socket circuits and heavy-duty 32A appliance circuits, addressing applications where 16A is insufficient but 32A would be overspecified and potentially unsafe for the connected equipment. While a conventional MCB protects only against overcurrent and short circuits, and a standalone RCD provides only earth leakage detection often shared across multiple circuits, this integrated RCBO delivers both protection mechanisms simultaneously within a single 1-module DIN rail footprint. This integration is particularly valuable for dedicated high-power appliance circuits where equipment with electronic controls (dishwashers, high-end washing machines, commercial coffee machines) requires both precise overcurrent protection and Type A earth leakage detection. The 20-ampere rating makes this RCBO perfect for dedicated appliance circuits for 4.6kW electric water heaters and immersion heaters, commercial catering equipment including urns, boilers, and holding cabinets, workshop machinery including table saws, planers, and dust extractors, air conditioning units up to approximately 4.6kW cooling capacity, electric vehicle charging (slow charging up to 4.6kW), small commercial ovens and microwave ovens, and any general purpose power circuit requiring 20A protection with both fault current and earth leakage detection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFurthermore, the Type A residual current characteristic elevates this RCBO above basic AC-type protection devices that are increasingly inadequate for modern electrical installations. Standard AC-type RCDs detect only smooth sinusoidal AC leakage currents—adequate for pure resistive loads like simple heating elements but dangerously ineffective for contemporary appliances containing electronic controls and switch-mode power supplies. Modern equipment including high-end washing machines with inverter motors, dishwasher control boards, air conditioning units with variable speed compressors, induction hobs, microwave ovens with inverter technology, EV chargers, and commercial coffee machines all generate pulsating DC leakage currents that can desensitize AC-type RCDs, causing them to fail to trip when dangerous leakage occurs. The Type A rating detects both AC sinusoidal and pulsating DC residual currents, providing comprehensive protection for today's mixed-technology electrical systems. With 30mA sensitivity—the internationally recognized standard for personnel protection against electric shock—this RCBO will trip within milliseconds (typically less than 40ms at 5x IΔn) when leakage current exceeds 30mA, long before ventricular fibrillation can occur. The mechanical endurance rating of 30,000 operations ensures long-term reliability for frequently switched circuits, while the electrical endurance of 10,000 cycles provides confidence for permanent installations. The operating temperature range of -5°C to +55°C accommodates most indoor installation environments. For any 20A-rated higher-power circuit where both overcurrent protection and advanced earth leakage detection are required, this Type A RCBO delivers uncompromising integrated safety in a compact, space-saving 1-module package.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComplete 2-in-1 Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Integrates MCB overcurrent protection and RCD earth leakage protection in a single 1-module unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSuperior Breaking Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Provides Icn=6kA and Ics=7.5kA (Ics higher than Icn for enhanced reliability)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType A Residual Current Detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Detects both sinusoidal AC and pulsating DC leakage currents for modern electronic loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e30mA Personnel Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Standard sensitivity for electric shock protection with millisecond trip response\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eB-Curve Magnetic Trip\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 3-5x rated current (60-100A) tripping characteristic ideal for higher-power appliance and equipment circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSingle-Pole Compact Design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 1P configuration with 1 module width for space-saving DIN rail installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eExceptional Cycle Life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Rated for 30,000 mechanical operations and 10,000 electrical operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eGenerous Cable Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Pillar terminals accept up to 25mm² conductors for flexible installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIP20 Protection Rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Suitable for installation within consumer units, distribution boards, and enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Functions reliably from -5°C to +55°C, stores from -25°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Dielectric Strength\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 2500V insulation withstand for enhanced electrical safety\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTop Supply Orientation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Designated power supply direction for correct and safe operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e RCBO (Residual Current Breaker with Overcurrent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 20 Amperes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Poles:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1P (1 module width)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230\/240VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eShort-Circuit Breaking Capacity (Icn):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 6kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eService Breaking Capacity (Ics):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 7.5kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMagnetic Tripping Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e B Curve (3-5x In = 60-100A trip range)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eResidual Tripping Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Type A (AC sinusoidal + pulsating DC detection)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Residual Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMechanical Endurance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Endurance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFrequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Strength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2500V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply Orientation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Top supply only (UP)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Pillar type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Cable Termination:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25mm²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eScrew Torque:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.5 Nm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection Grade:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -5°C to +55°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStorage Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -25°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandards Compliance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IEC\/EN61009-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. What appliances or equipment require a 20A RCBO rather than a 16A or 32A?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA 20A RCBO is ideal for appliances with power ratings between 3.68kW and 4.6kW (at 230V). Common examples include larger electric water heaters and immersion heaters (3kW-4.6kW), commercial coffee machines and urns, workshop machinery like table saws and planers, air conditioning units (up to 4.6kW cooling capacity), small commercial ovens, high-end washing machines and dryers with inverter motors, and dedicated circuits for multiple appliances in a commercial kitchen. If your appliance rating exceeds 4.6kW, upgrade to a 32A RCBO.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. Why does a 20A circuit with modern appliances specifically need Type A RCBO protection?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eModern appliances including inverter washing machines, dishwasher control boards, air conditioning units with variable speed compressors, induction hobs, and commercial coffee machines all contain switch-mode power supplies and electronic controls that generate pulsating DC leakage currents. Standard AC-type RCDs can become desensitized by these pulsating DC waveforms and may fail to trip when dangerous earth leakage occurs. Type A RCBOs are specifically designed to detect both AC sinusoidal and pulsating DC leakage, ensuring continued protection for circuits powering modern electronic equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. Can I replace an existing 20A MCB with this 20A RCBO without rewiring?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIn most cases yes, provided your consumer unit accepts 1-module wide RCBOs on a standard 35mm DIN rail and has an available neutral bar connection. The existing line conductor connects to the RCBO's line terminal (typically from the busbar), and you will need to connect the RCBO's flying neutral lead to the neutral bar. The circuit's neutral conductor must be disconnected from the neutral bar and connected to the RCBO's neutral terminal. The existing cable size (minimum 2.5mm² for 20A circuits) is usually sufficient. Always isolate the consumer unit before any replacement and verify compatibility with your specific distribution board.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. What is the significance of Ics=7.5kA being higher than Icn=6kA on this RCBO?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIcn (6kA) is the rated short-circuit breaking capacity—the maximum fault current this RCBO can interrupt once and remain safe for continued use. Ics (7.5kA) is the service short-circuit breaking capacity—the fault current the RCBO can interrupt and still remain fully functional for normal service. Having Ics higher than Icn is a premium reliability feature. It means if this RCBO clears a fault up to 7.5kA (25% higher than its rated capacity), it will continue operating correctly without needing replacement. Most standard protective devices require replacement after clearing any fault at their Icn rating. This provides superior reliability and lower maintenance costs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. What is the maximum cable length for a 20A circuit protected by this RCBO?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe maximum cable length depends on conductor size, installation method, and acceptable voltage drop (3% for lighting, 5% for power per BS 7671). For a 20A power circuit using 2.5mm² cable (minimum recommended for 20A): maximum length approximately 38 metres for 5% voltage drop. For 4mm² cable: approximately 60 metres for 5% drop. For 6mm² cable: approximately 90 metres for 5% drop. Longer runs require larger cable sizes to maintain voltage drop limits and ensure adequate earth fault loop impedance for rapid tripping. For circuits exceeding 50 metres, 6mm² or larger is typically recommended. Always calculate based on your specific installation conditions and regulatory requirements.\u003c\/span\u003e\u003c\/p\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57290412556670,"sku":null,"price":9.56,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/Untitled-design-94_3ee06f8b-6d26-46ac-9a7e-136cd6c493f0.png?v=1776718849","url":"https:\/\/ssmelectric.co.uk\/products\/advanced-dual-protection-6ka-20a-rcbo-with-type-a-30ma-safety","provider":"SSM ELECTRIC","version":"1.0","type":"link"}