{"product_id":"40a-type-a-mini-rcbo","title":"Live Electrical RSA140B-030 Single Module 40A B Curve 6kA 30mA Type A Mini RCBO","description":"\u003ch1 data-end=\"770\" data-start=\"467\"\u003eLive Electrical 40A B Curve 6kA 30mA Type A Mini RCBO\u003c\/h1\u003e\n\u003cp data-end=\"770\" data-start=\"467\"\u003eThe Live Electrical RSA140B-030 40A Type A Mini RCBO provides reliable protection for high-load and dedicated electrical circuits. Designed for UK \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/consumer-units\" target=\"_blank\" title=\"consumer unit\" rel=\"noopener\"\u003econsumer units\u003c\/a\u003e, this compact single-module \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/rcbos\" title=\"rcbo\"\u003eRCBO\u003c\/a\u003e combines overload, short circuit, and 30mA earth leakage protection to ensure maximum safety and compliance.\u003c\/p\u003e\n\u003cp data-end=\"932\" data-start=\"772\"\u003eIdeal for domestic and light commercial installations, it helps prevent electric shock, insulation faults, and fire risks while meeting BS EN 61009-1 standards.\u003c\/p\u003e\n\u003chr data-end=\"937\" data-start=\"934\"\u003e\n\u003ch2 data-end=\"964\" data-start=\"939\"\u003eKEY FEATURES\u003c\/h2\u003e\n\u003cp data-end=\"1294\" data-start=\"966\"\u003e✔ Switching \u0026amp; isolation capability\u003cbr data-end=\"1003\" data-start=\"1000\"\u003e✔ Overload \u0026amp; short circuit protection\u003cbr data-end=\"1043\" data-start=\"1040\"\u003e✔ 30mA earth leakage protection\u003cbr data-end=\"1077\" data-start=\"1074\"\u003e✔ Protection against sinusoidal fault currents\u003cbr data-end=\"1126\" data-start=\"1123\"\u003e✔ Direct \u0026amp; indirect contact protection\u003cbr data-end=\"1167\" data-start=\"1164\"\u003e✔ Reduces fire risk from insulation faults\u003cbr data-end=\"1212\" data-start=\"1209\"\u003e✔ Compact single module design\u003cbr data-end=\"1245\" data-start=\"1242\"\u003e✔ Type A protection for modern electrical loads\u003c\/p\u003e\n\u003chr data-end=\"1299\" data-start=\"1296\"\u003e\n\u003ch2 data-end=\"1338\" data-start=\"1301\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cul data-end=\"1636\" data-start=\"1340\"\u003e\n\u003cli data-end=\"1369\" data-start=\"1340\"\u003e\n\u003cp data-end=\"1369\" data-start=\"1342\"\u003eProduct Code: RSA140B-030\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1393\" data-start=\"1370\"\u003e\n\u003cp data-end=\"1393\" data-start=\"1372\"\u003eCurrent Rating: 40A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1415\" data-start=\"1394\"\u003e\n\u003cp data-end=\"1415\" data-start=\"1396\"\u003eTripping Curve: B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1442\" data-start=\"1416\"\u003e\n\u003cp data-end=\"1442\" data-start=\"1418\"\u003eBreaking Capacity: 6kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1469\" data-start=\"1443\"\u003e\n\u003cp data-end=\"1469\" data-start=\"1445\"\u003eResidual Current: 30mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1493\" data-start=\"1470\"\u003e\n\u003cp data-end=\"1493\" data-start=\"1472\"\u003eDevice Type: Type A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1514\" data-start=\"1494\"\u003e\n\u003cp data-end=\"1514\" data-start=\"1496\"\u003eVoltage: 230V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1529\" data-start=\"1515\"\u003e\n\u003cp data-end=\"1529\" data-start=\"1517\"\u003eModules: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1568\" data-start=\"1530\"\u003e\n\u003cp data-end=\"1568\" data-start=\"1532\"\u003eElectrical endurance: 4,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1608\" data-start=\"1569\"\u003e\n\u003cp data-end=\"1608\" data-start=\"1571\"\u003eMechanical endurance: 10,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1636\" data-start=\"1609\"\u003e\n\u003cp data-end=\"1636\" data-start=\"1611\"\u003eStandard: BS EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1641\" data-start=\"1638\"\u003e\n\u003ch3 data-end=\"1660\" data-start=\"1643\"\u003eFAQs\u003c\/h3\u003e\n\u003ch3 data-end=\"1694\" data-start=\"1662\"\u003eWhat is a 40A RCBO used for?\u003c\/h3\u003e\n\u003cp data-end=\"1807\" data-start=\"1695\"\u003eA 40A RCBO is commonly used for heavy-duty circuits, power distribution, cookers, showers, and large appliances.\u003c\/p\u003e\n\u003ch3 data-end=\"1846\" data-start=\"1809\"\u003eWhat does Type A protection mean?\u003c\/h3\u003e\n\u003cp data-end=\"1939\" data-start=\"1847\"\u003eType A RCBO detects AC and pulsating DC earth fault currents from modern electrical devices.\u003c\/p\u003e\n\u003ch3 data-end=\"1978\" data-start=\"1941\"\u003eWhy is 30mA protection important?\u003c\/h3\u003e\n\u003cp data-end=\"2059\" data-start=\"1979\"\u003e30mA sensitivity disconnects power quickly to protect users from electric shock.\u003c\/p\u003e\n\u003ch3 data-end=\"2109\" data-start=\"2061\"\u003eIs this RCBO suitable for UK consumer units?\u003c\/h3\u003e\n\u003cp data-end=\"2172\" data-start=\"2110\"\u003eYes, it complies with BS EN 61009-1 and UK wiring regulations.\u003c\/p\u003e\n\u003ch3 data-end=\"2211\" data-start=\"2174\"\u003eDoes this replace an RCD and MCB?\u003c\/h3\u003e\n\u003cp data-end=\"2275\" data-start=\"2212\"\u003eYes, an RCBO combines both protections into one compact device.\u003c\/p\u003e","brand":"SSM ELECTRIC","offers":[{"title":"Default Title","offer_id":56994397094270,"sku":"RSA140B-030","price":9.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/LiveElectrical40ATypeAMiniRCBO30mA6kA.png?v=1772233562","url":"https:\/\/ssmelectric.co.uk\/products\/40a-type-a-mini-rcbo","provider":"SSM ELECTRIC","version":"1.0","type":"link"}