{"product_id":"20a-type-a-mini-rcbo","title":"Live Electrical RSA120B-030 Single Module 20A B Curve 6kA 30mA Type A Mini RCBO","description":"\u003ch1 data-start=\"488\" data-end=\"792\"\u003eLive Electrical 20A B Curve 6kA 30mA Type A Mini RCBO\u003c\/h1\u003e\n\u003cp data-start=\"488\" data-end=\"792\"\u003eThe Live Electrical RSA120B-030 20A Type A Mini RCBO delivers reliable circuit protection for higher-load circuits and dedicated appliances. Designed for UK \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/consumer-units\" target=\"_blank\" title=\"live electrical consumer unit \" rel=\"noopener\"\u003econsumer units\u003c\/a\u003e, this compact single-module \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/rcbos\" title=\"rcbos\"\u003eR\u003c\/a\u003e\u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/rcbos\" target=\"_blank\" title=\"rcbos\" rel=\"noopener\"\u003eCB\u003c\/a\u003e\u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/rcbos\" title=\"rcbos\"\u003eO\u003c\/a\u003e combines overload, short circuit, and 30mA earth leakage protection for enhanced electrical safety.\u003c\/p\u003e\n\u003cp data-start=\"794\" data-end=\"963\"\u003eIdeal for domestic and light commercial installations, it helps prevent electric shock, insulation faults, and fire hazards while ensuring compliance with BS EN 61009-1.\u003c\/p\u003e\n\u003chr data-start=\"965\" data-end=\"968\"\u003e\n\u003ch2 data-start=\"970\" data-end=\"995\"\u003eKEY FEATURES\u003c\/h2\u003e\n\u003cp data-start=\"997\" data-end=\"1330\"\u003e✔ Switching \u0026amp; isolation capability\u003cbr data-start=\"1031\" data-end=\"1034\"\u003e✔ Overload \u0026amp; short circuit protection\u003cbr data-start=\"1071\" data-end=\"1074\"\u003e✔ 30mA earth leakage protection\u003cbr data-start=\"1105\" data-end=\"1108\"\u003e✔ Protection against sinusoidal fault currents\u003cbr data-start=\"1154\" data-end=\"1157\"\u003e✔ Direct \u0026amp; indirect contact protection\u003cbr data-start=\"1195\" data-end=\"1198\"\u003e✔ Helps reduce fire risk from insulation faults\u003cbr data-start=\"1245\" data-end=\"1248\"\u003e✔ Compact single module design\u003cbr data-start=\"1278\" data-end=\"1281\"\u003e✔ Type A protection for modern electrical loads\u003c\/p\u003e\n\u003chr data-start=\"1332\" data-end=\"1335\"\u003e\n\u003ch2 data-start=\"1337\" data-end=\"1374\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cul data-start=\"1376\" data-end=\"1672\"\u003e\n\u003cli data-start=\"1376\" data-end=\"1405\"\u003e\n\u003cp data-start=\"1378\" data-end=\"1405\"\u003eProduct Code: RSA120B-030\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1406\" data-end=\"1429\"\u003e\n\u003cp data-start=\"1408\" data-end=\"1429\"\u003eCurrent Rating: 20A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1451\"\u003e\n\u003cp data-start=\"1432\" data-end=\"1451\"\u003eTripping Curve: B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1452\" data-end=\"1478\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1478\"\u003eBreaking Capacity: 6kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1479\" data-end=\"1505\"\u003e\n\u003cp data-start=\"1481\" data-end=\"1505\"\u003eResidual Current: 30mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1506\" data-end=\"1529\"\u003e\n\u003cp data-start=\"1508\" data-end=\"1529\"\u003eDevice Type: Type A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1530\" data-end=\"1550\"\u003e\n\u003cp data-start=\"1532\" data-end=\"1550\"\u003eVoltage: 230V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1551\" data-end=\"1565\"\u003e\n\u003cp data-start=\"1553\" data-end=\"1565\"\u003eModules: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1566\" data-end=\"1604\"\u003e\n\u003cp data-start=\"1568\" data-end=\"1604\"\u003eElectrical endurance: 4,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1605\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1607\" data-end=\"1644\"\u003eMechanical endurance: 10,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1672\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1672\"\u003eStandard: BS EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1674\" data-end=\"1677\"\u003e\n\u003ch3 data-start=\"1679\" data-end=\"1696\"\u003eFAQs\u003c\/h3\u003e\n\u003ch3 data-start=\"1698\" data-end=\"1730\"\u003eWhat is a 20A RCBO used for?\u003c\/h3\u003e\n\u003cp data-start=\"1731\" data-end=\"1828\"\u003eA 20A RCBO is commonly used for boilers, fused spurs, kitchen appliances, and dedicated circuits.\u003c\/p\u003e\n\u003ch3 data-start=\"1830\" data-end=\"1870\"\u003eWhat does Type A RCBO protection do?\u003c\/h3\u003e\n\u003cp data-start=\"1871\" data-end=\"1963\"\u003eType A RCBO detects AC and pulsating DC earth fault currents from modern electronic devices.\u003c\/p\u003e\n\u003ch3 data-start=\"1965\" data-end=\"2002\"\u003eWhy is 30mA protection important?\u003c\/h3\u003e\n\u003cp data-start=\"2003\" data-end=\"2072\"\u003e30mA sensitivity disconnects power quickly to prevent electric shock.\u003c\/p\u003e\n\u003ch3 data-start=\"2074\" data-end=\"2117\"\u003eIs this suitable for UK consumer units?\u003c\/h3\u003e\n\u003cp data-start=\"2118\" data-end=\"2180\"\u003eYes, it complies with BS EN 61009-1 and UK wiring regulations.\u003c\/p\u003e\n\u003ch3 data-start=\"2182\" data-end=\"2219\"\u003eDoes this replace an RCD and MCB?\u003c\/h3\u003e\n\u003cp data-start=\"2220\" data-end=\"2275\"\u003eYes, an RCBO combines both protections into one device.\u003c\/p\u003e","brand":"LIVE ELECTRIC","offers":[{"title":"Default Title","offer_id":56994382512510,"sku":"RSA120B-030","price":9.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/LiveElectrical20ATypeAMiniRCBO30mA6kA.jpg?v=1772231979","url":"https:\/\/ssmelectric.co.uk\/products\/20a-type-a-mini-rcbo","provider":"SSM ELECTRIC","version":"1.0","type":"link"}