{"title":"RCBOs","description":"","products":[{"product_id":"live-electrical-6a-type-a-mini-rcbo-30ma","title":"Live Electrical RS106B-030 Single Module 6A B Curve 6kA 30mA Type A Mini RCBO","description":"\u003cp\u003eThe Live Electrical RS106B-030 Mini RCBO provides reliable circuit protection in a compact single-module design. Combining overload, short-circuit, and 30mA earth leakage protection, this Type A RCBO ensures safe and compliant electrical installations for domestic and light commercial use.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"907\" data-end=\"953\"\u003eKEY FEATURES (based on manufacturer data)\u003c\/h2\u003e\n\u003cp data-start=\"954\" data-end=\"1260\"\u003e✔ Switching and isolation capability\u003cbr data-start=\"990\" data-end=\"993\"\u003e✔ Overload and short circuit protection\u003cbr data-start=\"1032\" data-end=\"1035\"\u003e✔ Protection against sinusoidal earth fault currents\u003cbr data-start=\"1087\" data-end=\"1090\"\u003e✔ Direct and indirect contact protection\u003cbr data-start=\"1130\" data-end=\"1133\"\u003e✔ Reduces fire risk from insulation faults\u003cbr data-start=\"1175\" data-end=\"1178\"\u003e✔ Compact single module design\u003cbr data-start=\"1208\" data-end=\"1211\"\u003e✔ Type A protection for modern electrical loads\u003c\/p\u003e\n\u003chr data-start=\"1262\" data-end=\"1265\"\u003e\n\u003ch2 data-start=\"1267\" data-end=\"1296\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cul data-start=\"1297\" data-end=\"1590\"\u003e\n\u003cli data-start=\"1297\" data-end=\"1318\"\u003e\n\u003cp data-start=\"1299\" data-end=\"1318\"\u003eModel: RS106B-030\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1319\" data-end=\"1341\"\u003e\n\u003cp data-start=\"1321\" data-end=\"1341\"\u003eCurrent Rating: 6A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1342\" data-end=\"1363\"\u003e\n\u003cp data-start=\"1344\" data-end=\"1363\"\u003eTripping Curve: B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1364\" data-end=\"1390\"\u003e\n\u003cp data-start=\"1366\" data-end=\"1390\"\u003eBreaking Capacity: 6kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1391\" data-end=\"1417\"\u003e\n\u003cp data-start=\"1393\" data-end=\"1417\"\u003eResidual Current: 30mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1418\" data-end=\"1441\"\u003e\n\u003cp data-start=\"1420\" data-end=\"1441\"\u003eDevice Type: Type A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1442\" data-end=\"1468\"\u003e\n\u003cp data-start=\"1444\" data-end=\"1468\"\u003eRated Voltage: 230V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1469\" data-end=\"1507\"\u003e\n\u003cp data-start=\"1471\" data-end=\"1507\"\u003eElectrical Endurance: 4,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1508\" data-end=\"1547\"\u003e\n\u003cp data-start=\"1510\" data-end=\"1547\"\u003eMechanical Endurance: 10,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1548\" data-end=\"1575\"\u003e\n\u003cp data-start=\"1550\" data-end=\"1575\"\u003eStandard: BS EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1576\" data-end=\"1590\"\u003e\n\u003cp data-start=\"1578\" data-end=\"1590\"\u003eModules: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1592\" data-end=\"1595\"\u003e\n\u003ch2 data-start=\"1597\" data-end=\"1639\"\u003e FAQs \u003c\/h2\u003e\n\u003ch3 data-start=\"1641\" data-end=\"1685\"\u003eWhat does a Type A RCBO protect against?\u003c\/h3\u003e\n\u003cp data-start=\"1686\" data-end=\"1812\"\u003eType A RCBOs detect AC and pulsating DC earth fault currents, making them suitable for modern appliances and electronic loads.\u003c\/p\u003e\n\u003ch3 data-start=\"1814\" data-end=\"1852\"\u003eWhere is a 6A RCBO typically used?\u003c\/h3\u003e\n\u003cp data-start=\"1853\" data-end=\"1935\"\u003eA 6A RCBO is commonly used for lighting circuits and low-load electrical circuits.\u003c\/p\u003e\n\u003ch3 data-start=\"1937\" data-end=\"1961\"\u003eWhat does 30mA mean?\u003c\/h3\u003e\n\u003cp data-start=\"1962\" data-end=\"2070\"\u003e30mA sensitivity provides protection against electric shock by disconnecting power when leakage is detected.\u003c\/p\u003e\n\u003ch3 data-start=\"2072\" data-end=\"2119\"\u003eIs this RCBO compliant with UK regulations?\u003c\/h3\u003e\n\u003cp data-start=\"2120\" data-end=\"2194\"\u003eYes, it complies with BS EN 61009-1 and is suitable for UK consumer units.\u003c\/p\u003e\n\u003ch3 data-start=\"2196\" data-end=\"2229\"\u003eCan this RCBO replace an MCB?\u003c\/h3\u003e\n\u003cp data-start=\"2230\" data-end=\"2294\"\u003eYes. An RCBO combines both RCD and MCB protection in one device.\u003c\/p\u003e","brand":"LIVE ELECTRIC","offers":[{"title":"Default Title","offer_id":56994324021630,"sku":"RS106B-030","price":9.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/Live_Electrical_6A_Type_A_Mini_RCBO_30mA_6kA.jpg?v=1772229886"},{"product_id":"rcbo-10a-type-a-mini-rcbo","title":"Live Electrical RSA110B-030 Single Module 10A B Curve 6kA 30mA Type A Mini RCBO","description":"\u003ch1 data-end=\"747\" data-start=\"461\"\u003e10A B Curve 6kA 30mA Type A Mini RCBO\u003cbr\u003e\n\u003c\/h1\u003e\n\u003cp data-end=\"747\" data-start=\"461\"\u003eLive Electrical RSA110B-030 10A Type A Mini RCBO provides reliable circuit protection for lighting and low-load circuits. Designed for UK \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/consumer-units\" target=\"_blank\"\u003econsumer units\u003c\/a\u003e, this compact single-module RCBO combines overload, short circuit, and 30mA earth leakage protection to ensure electrical safety.\u003c\/p\u003e\n\u003cp data-end=\"975\" data-start=\"749\"\u003eIdeal for domestic and light commercial installations, this \u003ca rel=\"noopener\" href=\"https:\/\/ssmelectric.co.uk\/collections\/rcbos\" target=\"_blank\"\u003eRCBO\u003c\/a\u003e detects sinusoidal earth fault currents and protects against insulation faults, helping reduce fire risks while ensuring compliance with BS EN 61009-1 standards.\u003c\/p\u003e\n\u003chr data-end=\"980\" data-start=\"977\"\u003e\n\u003ch2 data-end=\"1007\" data-start=\"982\"\u003eKEY FEATURES\u003c\/h2\u003e\n\u003cp data-end=\"1338\" data-start=\"1009\"\u003e✔ Switching \u0026amp; isolation capability\u003cbr data-end=\"1046\" data-start=\"1043\"\u003e✔ Overload \u0026amp; short circuit protection\u003cbr data-end=\"1086\" data-start=\"1083\"\u003e✔ Earth leakage protection (30mA)\u003cbr data-end=\"1122\" data-start=\"1119\"\u003e✔ Protection against sinusoidal fault currents\u003cbr data-end=\"1171\" data-start=\"1168\"\u003e✔ Direct \u0026amp; indirect contact protection\u003cbr data-end=\"1212\" data-start=\"1209\"\u003e✔ Helps reduce fire risk from insulation faults\u003cbr data-end=\"1262\" data-start=\"1259\"\u003e✔ Compact single module design\u003cbr data-end=\"1295\" data-start=\"1292\"\u003e✔ Type A protection for modern appliances\u003c\/p\u003e\n\u003chr data-end=\"1343\" data-start=\"1340\"\u003e\n\u003ch2 data-end=\"1382\" data-start=\"1345\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cul data-end=\"1680\" data-start=\"1384\"\u003e\n\u003cli data-end=\"1413\" data-start=\"1384\"\u003e\n\u003cp data-end=\"1413\" data-start=\"1386\"\u003eProduct Code: RSA110B-030\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1437\" data-start=\"1414\"\u003e\n\u003cp data-end=\"1437\" data-start=\"1416\"\u003eCurrent Rating: 10A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1459\" data-start=\"1438\"\u003e\n\u003cp data-end=\"1459\" data-start=\"1440\"\u003eTripping Curve: B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1486\" data-start=\"1460\"\u003e\n\u003cp data-end=\"1486\" data-start=\"1462\"\u003eBreaking Capacity: 6kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1513\" data-start=\"1487\"\u003e\n\u003cp data-end=\"1513\" data-start=\"1489\"\u003eResidual Current: 30mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1537\" data-start=\"1514\"\u003e\n\u003cp data-end=\"1537\" data-start=\"1516\"\u003eDevice Type: Type A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1558\" data-start=\"1538\"\u003e\n\u003cp data-end=\"1558\" data-start=\"1540\"\u003eVoltage: 230V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1573\" data-start=\"1559\"\u003e\n\u003cp data-end=\"1573\" data-start=\"1561\"\u003eModules: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1612\" data-start=\"1574\"\u003e\n\u003cp data-end=\"1612\" data-start=\"1576\"\u003eElectrical endurance: 4,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1652\" data-start=\"1613\"\u003e\n\u003cp data-end=\"1652\" data-start=\"1615\"\u003eMechanical endurance: 10,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1680\" data-start=\"1653\"\u003e\n\u003cp data-end=\"1680\" data-start=\"1655\"\u003eStandard: BS EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1685\" data-start=\"1682\"\u003e\n\u003ch2 data-end=\"1728\" data-start=\"1687\"\u003eFAQs \u003c\/h2\u003e\n\u003ch3 data-end=\"1762\" data-start=\"1730\"\u003eWhat is a 10A RCBO used for?\u003c\/h3\u003e\n\u003cp data-end=\"1840\" data-start=\"1763\"\u003eA 10A RCBO is commonly used for lighting circuits and small electrical loads.\u003c\/p\u003e\n\u003ch3 data-end=\"1879\" data-start=\"1842\"\u003eWhat does Type A protection mean?\u003c\/h3\u003e\n\u003cp data-end=\"1989\" data-start=\"1880\"\u003eType A RCBO detects both AC and pulsating DC earth fault currents, making it suitable for modern electronics.\u003c\/p\u003e\n\u003ch3 data-end=\"2028\" data-start=\"1991\"\u003eWhy is 30mA protection important?\u003c\/h3\u003e\n\u003cp data-end=\"2106\" data-start=\"2029\"\u003e30mA sensitivity disconnects power quickly to protect against electric shock.\u003c\/p\u003e\n\u003ch3 data-end=\"2155\" data-start=\"2108\"\u003eCan this RCBO be used in UK consumer units?\u003c\/h3\u003e\n\u003cp data-end=\"2229\" data-start=\"2156\"\u003eYes, it complies with BS EN 61009-1 and is designed for UK installations.\u003c\/p\u003e\n\u003ch3 data-end=\"2263\" data-start=\"2231\"\u003eDoes an RCBO replace an MCB?\u003c\/h3\u003e\n\u003cp data-end=\"2318\" data-start=\"2264\"\u003eYes. It combines RCD and MCB protection in one device.\u003c\/p\u003e","brand":"LIVE ELECTRIC","offers":[{"title":"Default Title","offer_id":56994330345854,"sku":"RSA110B-030","price":9.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/Live_Electrical_10A_Type_A_Mini_RCBO_30mA_6kA.jpg?v=1772230727"},{"product_id":"16a-type-a-mini-rcbo","title":"Live Electrical RSA116B-030 Single Module 16A B Curve 6kA 30mA Type A Mini RCBO","description":"\u003ch1 data-start=\"447\" data-end=\"757\"\u003e16A B Curve 6kA 30mA Type A Mini RCBO\u003c\/h1\u003e\n\u003cp data-start=\"447\" data-end=\"757\"\u003eThe Live Electrical RSA116B-030 16A Type A Mini RCBO provides reliable circuit protection for socket outlets and medium-load circuits. Designed for UK \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/consumer-units\" target=\"_blank\" title=\"consumer unit \" rel=\"noopener\"\u003econsumer\u003c\/a\u003e units, this compact single-module \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/rcbos\" title=\"rcbo\"\u003eRCBO\u003c\/a\u003e combines overload, short circuit, and 30mA earth leakage protection to ensure electrical safety and compliance.\u003c\/p\u003e\n\u003cp data-start=\"759\" data-end=\"900\"\u003eIdeal for domestic and light commercial installations, it detects earth fault currents and insulation faults while helping reduce fire risks.\u003c\/p\u003e\n\u003chr data-start=\"902\" data-end=\"905\"\u003e\n\u003ch2 data-start=\"907\" data-end=\"932\"\u003eKEY FEATURES\u003c\/h2\u003e\n\u003cp data-start=\"934\" data-end=\"1261\"\u003e✔ Switching \u0026amp; isolation capability\u003cbr data-start=\"968\" data-end=\"971\"\u003e✔ Overload \u0026amp; short circuit protection\u003cbr data-start=\"1008\" data-end=\"1011\"\u003e✔ 30mA earth leakage protection\u003cbr data-start=\"1042\" data-end=\"1045\"\u003e✔ Protection against sinusoidal fault currents\u003cbr data-start=\"1091\" data-end=\"1094\"\u003e✔ Direct \u0026amp; indirect contact protection\u003cbr data-start=\"1132\" data-end=\"1135\"\u003e✔ Helps reduce fire risk from insulation faults\u003cbr data-start=\"1182\" data-end=\"1185\"\u003e✔ Compact single module design\u003cbr data-start=\"1215\" data-end=\"1218\"\u003e✔ Type A protection for modern appliances\u003c\/p\u003e\n\u003chr data-start=\"1263\" data-end=\"1266\"\u003e\n\u003ch2 data-start=\"1268\" data-end=\"1305\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cul data-start=\"1307\" data-end=\"1603\"\u003e\n\u003cli data-start=\"1307\" data-end=\"1336\"\u003e\n\u003cp data-start=\"1309\" data-end=\"1336\"\u003eProduct Code: RSA116B-030\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1337\" data-end=\"1360\"\u003e\n\u003cp data-start=\"1339\" data-end=\"1360\"\u003eCurrent Rating: 16A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1361\" data-end=\"1382\"\u003e\n\u003cp data-start=\"1363\" data-end=\"1382\"\u003eTripping Curve: B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1383\" data-end=\"1409\"\u003e\n\u003cp data-start=\"1385\" data-end=\"1409\"\u003eBreaking Capacity: 6kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1410\" data-end=\"1436\"\u003e\n\u003cp data-start=\"1412\" data-end=\"1436\"\u003eResidual Current: 30mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1437\" data-end=\"1460\"\u003e\n\u003cp data-start=\"1439\" data-end=\"1460\"\u003eDevice Type: Type A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1461\" data-end=\"1481\"\u003e\n\u003cp data-start=\"1463\" data-end=\"1481\"\u003eVoltage: 230V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1482\" data-end=\"1496\"\u003e\n\u003cp data-start=\"1484\" data-end=\"1496\"\u003eModules: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1497\" data-end=\"1535\"\u003e\n\u003cp data-start=\"1499\" data-end=\"1535\"\u003eElectrical endurance: 4,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1536\" data-end=\"1575\"\u003e\n\u003cp data-start=\"1538\" data-end=\"1575\"\u003eMechanical endurance: 10,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1576\" data-end=\"1603\"\u003e\n\u003cp data-start=\"1578\" data-end=\"1603\"\u003eStandard: BS EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1605\" data-end=\"1608\"\u003e\n\u003ch3 data-start=\"1610\" data-end=\"1627\"\u003eFAQs\u003c\/h3\u003e\n\u003ch3 data-start=\"1629\" data-end=\"1661\"\u003eWhat is a 16A RCBO used for?\u003c\/h3\u003e\n\u003cp data-start=\"1662\" data-end=\"1736\"\u003eA 16A RCBO is commonly used for socket outlets and general power circuits.\u003c\/p\u003e\n\u003ch3 data-start=\"1738\" data-end=\"1775\"\u003eWhat does Type A protection mean?\u003c\/h3\u003e\n\u003cp data-start=\"1776\" data-end=\"1871\"\u003eType A RCBO detects AC and pulsating DC fault currents, suitable for modern electrical devices.\u003c\/p\u003e\n\u003ch3 data-start=\"1873\" data-end=\"1910\"\u003eWhy is 30mA protection important?\u003c\/h3\u003e\n\u003cp data-start=\"1911\" data-end=\"1991\"\u003e30mA sensitivity disconnects power quickly to protect users from electric shock.\u003c\/p\u003e\n\u003ch3 data-start=\"1993\" data-end=\"2041\"\u003eIs this RCBO suitable for UK consumer units?\u003c\/h3\u003e\n\u003cp data-start=\"2042\" data-end=\"2104\"\u003eYes, it complies with BS EN 61009-1 and UK wiring regulations.\u003c\/p\u003e\n\u003ch3 data-start=\"2106\" data-end=\"2148\"\u003eDoes this replace both an RCD and MCB?\u003c\/h3\u003e\n\u003cp data-start=\"2149\" data-end=\"2210\"\u003eYes, an RCBO combines both protections in one compact device.\u003c\/p\u003e","brand":"LIVE ELECTRIC","offers":[{"title":"Default Title","offer_id":56994363277694,"sku":"RSA116B-030","price":9.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/Live_Electrical_16A_Type_A_Mini_RCBO_30mA_6kA.jpg?v=1772231456"},{"product_id":"20a-type-a-mini-rcbo","title":"Live Electrical RSA120B-030 Single Module 20A B Curve 6kA 30mA Type A Mini RCBO","description":"\u003ch1 data-start=\"488\" data-end=\"792\"\u003eLive Electrical 20A B Curve 6kA 30mA Type A Mini RCBO\u003c\/h1\u003e\n\u003cp data-start=\"488\" data-end=\"792\"\u003eThe Live Electrical RSA120B-030 20A Type A Mini RCBO delivers reliable circuit protection for higher-load circuits and dedicated appliances. Designed for UK \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/consumer-units\" target=\"_blank\" title=\"live electrical consumer unit \" rel=\"noopener\"\u003econsumer units\u003c\/a\u003e, this compact single-module \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/rcbos\" title=\"rcbos\"\u003eR\u003c\/a\u003e\u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/rcbos\" target=\"_blank\" title=\"rcbos\" rel=\"noopener\"\u003eCB\u003c\/a\u003e\u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/rcbos\" title=\"rcbos\"\u003eO\u003c\/a\u003e combines overload, short circuit, and 30mA earth leakage protection for enhanced electrical safety.\u003c\/p\u003e\n\u003cp data-start=\"794\" data-end=\"963\"\u003eIdeal for domestic and light commercial installations, it helps prevent electric shock, insulation faults, and fire hazards while ensuring compliance with BS EN 61009-1.\u003c\/p\u003e\n\u003chr data-start=\"965\" data-end=\"968\"\u003e\n\u003ch2 data-start=\"970\" data-end=\"995\"\u003eKEY FEATURES\u003c\/h2\u003e\n\u003cp data-start=\"997\" data-end=\"1330\"\u003e✔ Switching \u0026amp; isolation capability\u003cbr data-start=\"1031\" data-end=\"1034\"\u003e✔ Overload \u0026amp; short circuit protection\u003cbr data-start=\"1071\" data-end=\"1074\"\u003e✔ 30mA earth leakage protection\u003cbr data-start=\"1105\" data-end=\"1108\"\u003e✔ Protection against sinusoidal fault currents\u003cbr data-start=\"1154\" data-end=\"1157\"\u003e✔ Direct \u0026amp; indirect contact protection\u003cbr data-start=\"1195\" data-end=\"1198\"\u003e✔ Helps reduce fire risk from insulation faults\u003cbr data-start=\"1245\" data-end=\"1248\"\u003e✔ Compact single module design\u003cbr data-start=\"1278\" data-end=\"1281\"\u003e✔ Type A protection for modern electrical loads\u003c\/p\u003e\n\u003chr data-start=\"1332\" data-end=\"1335\"\u003e\n\u003ch2 data-start=\"1337\" data-end=\"1374\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cul data-start=\"1376\" data-end=\"1672\"\u003e\n\u003cli data-start=\"1376\" data-end=\"1405\"\u003e\n\u003cp data-start=\"1378\" data-end=\"1405\"\u003eProduct Code: RSA120B-030\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1406\" data-end=\"1429\"\u003e\n\u003cp data-start=\"1408\" data-end=\"1429\"\u003eCurrent Rating: 20A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1451\"\u003e\n\u003cp data-start=\"1432\" data-end=\"1451\"\u003eTripping Curve: B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1452\" data-end=\"1478\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1478\"\u003eBreaking Capacity: 6kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1479\" data-end=\"1505\"\u003e\n\u003cp data-start=\"1481\" data-end=\"1505\"\u003eResidual Current: 30mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1506\" data-end=\"1529\"\u003e\n\u003cp data-start=\"1508\" data-end=\"1529\"\u003eDevice Type: Type A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1530\" data-end=\"1550\"\u003e\n\u003cp data-start=\"1532\" data-end=\"1550\"\u003eVoltage: 230V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1551\" data-end=\"1565\"\u003e\n\u003cp data-start=\"1553\" data-end=\"1565\"\u003eModules: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1566\" data-end=\"1604\"\u003e\n\u003cp data-start=\"1568\" data-end=\"1604\"\u003eElectrical endurance: 4,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1605\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1607\" data-end=\"1644\"\u003eMechanical endurance: 10,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1672\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1672\"\u003eStandard: BS EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1674\" data-end=\"1677\"\u003e\n\u003ch3 data-start=\"1679\" data-end=\"1696\"\u003eFAQs\u003c\/h3\u003e\n\u003ch3 data-start=\"1698\" data-end=\"1730\"\u003eWhat is a 20A RCBO used for?\u003c\/h3\u003e\n\u003cp data-start=\"1731\" data-end=\"1828\"\u003eA 20A RCBO is commonly used for boilers, fused spurs, kitchen appliances, and dedicated circuits.\u003c\/p\u003e\n\u003ch3 data-start=\"1830\" data-end=\"1870\"\u003eWhat does Type A RCBO protection do?\u003c\/h3\u003e\n\u003cp data-start=\"1871\" data-end=\"1963\"\u003eType A RCBO detects AC and pulsating DC earth fault currents from modern electronic devices.\u003c\/p\u003e\n\u003ch3 data-start=\"1965\" data-end=\"2002\"\u003eWhy is 30mA protection important?\u003c\/h3\u003e\n\u003cp data-start=\"2003\" data-end=\"2072\"\u003e30mA sensitivity disconnects power quickly to prevent electric shock.\u003c\/p\u003e\n\u003ch3 data-start=\"2074\" data-end=\"2117\"\u003eIs this suitable for UK consumer units?\u003c\/h3\u003e\n\u003cp data-start=\"2118\" data-end=\"2180\"\u003eYes, it complies with BS EN 61009-1 and UK wiring regulations.\u003c\/p\u003e\n\u003ch3 data-start=\"2182\" data-end=\"2219\"\u003eDoes this replace an RCD and MCB?\u003c\/h3\u003e\n\u003cp data-start=\"2220\" data-end=\"2275\"\u003eYes, an RCBO combines both protections into one device.\u003c\/p\u003e","brand":"LIVE ELECTRIC","offers":[{"title":"Default Title","offer_id":56994382512510,"sku":"RSA120B-030","price":9.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/LiveElectrical20ATypeAMiniRCBO30mA6kA.jpg?v=1772231979"},{"product_id":"32a-type-a-mini-rcbo","title":"Live Electrical RSA132B-030 Single Module 32A B Curve 6kA 30mA Type A Mini RCBO","description":"\u003ch1 data-start=\"479\" data-end=\"786\"\u003eLive Electrical 32A B Curve 6kA 30mA Type A Mini RCBO\u003c\/h1\u003e\n\u003cp data-start=\"479\" data-end=\"786\"\u003eThe Live Electrical RSA132B-030 32A Type A Mini RCBO provides dependable circuit protection for high-load circuits and power distribution. Designed for UK consumer units, this compact single-module RCBO combines overload, short circuit, and 30mA earth leakage protection to ensure maximum electrical safety.\u003c\/p\u003e\n\u003cp data-start=\"788\" data-end=\"955\"\u003eIdeal for domestic and light commercial installations, it helps prevent electric shock, insulation faults, and fire risks while complying with BS EN 61009-1 standards.\u003c\/p\u003e\n\u003chr data-start=\"957\" data-end=\"960\"\u003e\n\u003ch2 data-start=\"962\" data-end=\"987\"\u003eKEY FEATURES\u003c\/h2\u003e\n\u003cp data-start=\"989\" data-end=\"1317\"\u003e✔ Switching \u0026amp; isolation capability\u003cbr data-start=\"1023\" data-end=\"1026\"\u003e✔ Overload \u0026amp; short circuit protection\u003cbr data-start=\"1063\" data-end=\"1066\"\u003e✔ 30mA earth leakage protection\u003cbr data-start=\"1097\" data-end=\"1100\"\u003e✔ Protection against sinusoidal fault currents\u003cbr data-start=\"1146\" data-end=\"1149\"\u003e✔ Direct \u0026amp; indirect contact protection\u003cbr data-start=\"1187\" data-end=\"1190\"\u003e✔ Reduces fire risk from insulation faults\u003cbr data-start=\"1232\" data-end=\"1235\"\u003e✔ Compact single module design\u003cbr data-start=\"1265\" data-end=\"1268\"\u003e✔ Type A protection for modern electrical loads\u003c\/p\u003e\n\u003chr data-start=\"1319\" data-end=\"1322\"\u003e\n\u003ch2 data-start=\"1324\" data-end=\"1361\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cul data-start=\"1363\" data-end=\"1659\"\u003e\n\u003cli data-start=\"1363\" data-end=\"1392\"\u003e\n\u003cp data-start=\"1365\" data-end=\"1392\"\u003eProduct Code: RSA132B-030\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1393\" data-end=\"1416\"\u003e\n\u003cp data-start=\"1395\" data-end=\"1416\"\u003eCurrent Rating: 32A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1417\" data-end=\"1438\"\u003e\n\u003cp data-start=\"1419\" data-end=\"1438\"\u003eTripping Curve: B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1439\" data-end=\"1465\"\u003e\n\u003cp data-start=\"1441\" data-end=\"1465\"\u003eBreaking Capacity: 6kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1466\" data-end=\"1492\"\u003e\n\u003cp data-start=\"1468\" data-end=\"1492\"\u003eResidual Current: 30mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1493\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1495\" data-end=\"1516\"\u003eDevice Type: Type A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1517\" data-end=\"1537\"\u003e\n\u003cp data-start=\"1519\" data-end=\"1537\"\u003eVoltage: 230V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1538\" data-end=\"1552\"\u003e\n\u003cp data-start=\"1540\" data-end=\"1552\"\u003eModules: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1553\" data-end=\"1591\"\u003e\n\u003cp data-start=\"1555\" data-end=\"1591\"\u003eElectrical endurance: 4,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1592\" data-end=\"1631\"\u003e\n\u003cp data-start=\"1594\" data-end=\"1631\"\u003eMechanical endurance: 10,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1632\" data-end=\"1659\"\u003e\n\u003cp data-start=\"1634\" data-end=\"1659\"\u003eStandard: BS EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1661\" data-end=\"1664\"\u003e\n\u003ch3 data-start=\"1666\" data-end=\"1683\"\u003eFAQs\u003c\/h3\u003e\n\u003ch3 data-start=\"1685\" data-end=\"1717\"\u003eWhat is a 32A RCBO used for?\u003c\/h3\u003e\n\u003cp data-start=\"1718\" data-end=\"1829\"\u003eA 32A RCBO is typically used for ring main circuits, cookers, showers, and other high-load electrical circuits.\u003c\/p\u003e\n\u003ch3 data-start=\"1831\" data-end=\"1868\"\u003eWhat does Type A protection mean?\u003c\/h3\u003e\n\u003cp data-start=\"1869\" data-end=\"1966\"\u003eType A RCBO detects AC and pulsating DC fault currents, making it suitable for modern appliances.\u003c\/p\u003e\n\u003ch3 data-start=\"1968\" data-end=\"2005\"\u003eWhy is 30mA protection important?\u003c\/h3\u003e\n\u003cp data-start=\"2006\" data-end=\"2083\"\u003e30mA sensitivity disconnects power quickly to protect against electric shock.\u003c\/p\u003e\n\u003ch3 data-start=\"2085\" data-end=\"2133\"\u003eIs this RCBO suitable for UK consumer units?\u003c\/h3\u003e\n\u003cp data-start=\"2134\" data-end=\"2196\"\u003eYes, it complies with BS EN 61009-1 and UK wiring regulations.\u003c\/p\u003e\n\u003ch3 data-start=\"2198\" data-end=\"2243\"\u003eDoes an RCBO replace both an RCD and MCB?\u003c\/h3\u003e\n\u003cp data-start=\"2244\" data-end=\"2307\"\u003eYes, an RCBO combines both protections into one compact device.\u003c\/p\u003e","brand":"LIVE ELECTRIC","offers":[{"title":"Default Title","offer_id":56994396275070,"sku":"RSA132B-030","price":9.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/LiveElectrical32ATypeAMiniRCBO30mA6kA.jpg?v=1772232416"},{"product_id":"40a-type-a-mini-rcbo","title":"Live Electrical RSA140B-030 Single Module 40A B Curve 6kA 30mA Type A Mini RCBO","description":"\u003ch1 data-end=\"770\" data-start=\"467\"\u003eLive Electrical 40A B Curve 6kA 30mA Type A Mini RCBO\u003c\/h1\u003e\n\u003cp data-end=\"770\" data-start=\"467\"\u003eThe Live Electrical RSA140B-030 40A Type A Mini RCBO provides reliable protection for high-load and dedicated electrical circuits. Designed for UK \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/consumer-units\" target=\"_blank\" title=\"consumer unit\" rel=\"noopener\"\u003econsumer units\u003c\/a\u003e, this compact single-module \u003ca href=\"https:\/\/ssmelectric.co.uk\/collections\/rcbos\" title=\"rcbo\"\u003eRCBO\u003c\/a\u003e combines overload, short circuit, and 30mA earth leakage protection to ensure maximum safety and compliance.\u003c\/p\u003e\n\u003cp data-end=\"932\" data-start=\"772\"\u003eIdeal for domestic and light commercial installations, it helps prevent electric shock, insulation faults, and fire risks while meeting BS EN 61009-1 standards.\u003c\/p\u003e\n\u003chr data-end=\"937\" data-start=\"934\"\u003e\n\u003ch2 data-end=\"964\" data-start=\"939\"\u003eKEY FEATURES\u003c\/h2\u003e\n\u003cp data-end=\"1294\" data-start=\"966\"\u003e✔ Switching \u0026amp; isolation capability\u003cbr data-end=\"1003\" data-start=\"1000\"\u003e✔ Overload \u0026amp; short circuit protection\u003cbr data-end=\"1043\" data-start=\"1040\"\u003e✔ 30mA earth leakage protection\u003cbr data-end=\"1077\" data-start=\"1074\"\u003e✔ Protection against sinusoidal fault currents\u003cbr data-end=\"1126\" data-start=\"1123\"\u003e✔ Direct \u0026amp; indirect contact protection\u003cbr data-end=\"1167\" data-start=\"1164\"\u003e✔ Reduces fire risk from insulation faults\u003cbr data-end=\"1212\" data-start=\"1209\"\u003e✔ Compact single module design\u003cbr data-end=\"1245\" data-start=\"1242\"\u003e✔ Type A protection for modern electrical loads\u003c\/p\u003e\n\u003chr data-end=\"1299\" data-start=\"1296\"\u003e\n\u003ch2 data-end=\"1338\" data-start=\"1301\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cul data-end=\"1636\" data-start=\"1340\"\u003e\n\u003cli data-end=\"1369\" data-start=\"1340\"\u003e\n\u003cp data-end=\"1369\" data-start=\"1342\"\u003eProduct Code: RSA140B-030\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1393\" data-start=\"1370\"\u003e\n\u003cp data-end=\"1393\" data-start=\"1372\"\u003eCurrent Rating: 40A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1415\" data-start=\"1394\"\u003e\n\u003cp data-end=\"1415\" data-start=\"1396\"\u003eTripping Curve: B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1442\" data-start=\"1416\"\u003e\n\u003cp data-end=\"1442\" data-start=\"1418\"\u003eBreaking Capacity: 6kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1469\" data-start=\"1443\"\u003e\n\u003cp data-end=\"1469\" data-start=\"1445\"\u003eResidual Current: 30mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1493\" data-start=\"1470\"\u003e\n\u003cp data-end=\"1493\" data-start=\"1472\"\u003eDevice Type: Type A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1514\" data-start=\"1494\"\u003e\n\u003cp data-end=\"1514\" data-start=\"1496\"\u003eVoltage: 230V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1529\" data-start=\"1515\"\u003e\n\u003cp data-end=\"1529\" data-start=\"1517\"\u003eModules: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1568\" data-start=\"1530\"\u003e\n\u003cp data-end=\"1568\" data-start=\"1532\"\u003eElectrical endurance: 4,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1608\" data-start=\"1569\"\u003e\n\u003cp data-end=\"1608\" data-start=\"1571\"\u003eMechanical endurance: 10,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1636\" data-start=\"1609\"\u003e\n\u003cp data-end=\"1636\" data-start=\"1611\"\u003eStandard: BS EN 61009-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1641\" data-start=\"1638\"\u003e\n\u003ch3 data-end=\"1660\" data-start=\"1643\"\u003eFAQs\u003c\/h3\u003e\n\u003ch3 data-end=\"1694\" data-start=\"1662\"\u003eWhat is a 40A RCBO used for?\u003c\/h3\u003e\n\u003cp data-end=\"1807\" data-start=\"1695\"\u003eA 40A RCBO is commonly used for heavy-duty circuits, power distribution, cookers, showers, and large appliances.\u003c\/p\u003e\n\u003ch3 data-end=\"1846\" data-start=\"1809\"\u003eWhat does Type A protection mean?\u003c\/h3\u003e\n\u003cp data-end=\"1939\" data-start=\"1847\"\u003eType A RCBO detects AC and pulsating DC earth fault currents from modern electrical devices.\u003c\/p\u003e\n\u003ch3 data-end=\"1978\" data-start=\"1941\"\u003eWhy is 30mA protection important?\u003c\/h3\u003e\n\u003cp data-end=\"2059\" data-start=\"1979\"\u003e30mA sensitivity disconnects power quickly to protect users from electric shock.\u003c\/p\u003e\n\u003ch3 data-end=\"2109\" data-start=\"2061\"\u003eIs this RCBO suitable for UK consumer units?\u003c\/h3\u003e\n\u003cp data-end=\"2172\" data-start=\"2110\"\u003eYes, it complies with BS EN 61009-1 and UK wiring regulations.\u003c\/p\u003e\n\u003ch3 data-end=\"2211\" data-start=\"2174\"\u003eDoes this replace an RCD and MCB?\u003c\/h3\u003e\n\u003cp data-end=\"2275\" data-start=\"2212\"\u003eYes, an RCBO combines both protections into one compact device.\u003c\/p\u003e","brand":"SSM ELECTRIC","offers":[{"title":"Default Title","offer_id":56994397094270,"sku":"RSA140B-030","price":9.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/LiveElectrical40ATypeAMiniRCBO30mA6kA.png?v=1772233562"},{"product_id":"switched-neutral-rcbo","title":"Live Electrical AMR Switched Neutral Type A RCBO 6kA 30mA","description":"","brand":"LIVE ELECTRIC","offers":[{"title":"6B","offer_id":56997125783934,"sku":"AMR106B-030","price":8.19,"currency_code":"GBP","in_stock":true},{"title":"10B","offer_id":56997125816702,"sku":"AMR110B-030","price":8.19,"currency_code":"GBP","in_stock":true},{"title":"16B","offer_id":56997125849470,"sku":"AMR116B-030","price":8.19,"currency_code":"GBP","in_stock":true},{"title":"20B","offer_id":56997125882238,"sku":"AMR120B-030","price":8.19,"currency_code":"GBP","in_stock":true},{"title":"25B","offer_id":56997125915006,"sku":"AMR125B-030","price":8.19,"currency_code":"GBP","in_stock":true},{"title":"132B","offer_id":56997125947774,"sku":"AMR132B-030","price":8.19,"currency_code":"GBP","in_stock":true},{"title":"40B","offer_id":56997125980542,"sku":null,"price":8.19,"currency_code":"GBP","in_stock":true},{"title":"6C","offer_id":56997126013310,"sku":"AMR106C-030","price":8.59,"currency_code":"GBP","in_stock":true},{"title":"10C","offer_id":56997126046078,"sku":"AMR110C-030","price":8.59,"currency_code":"GBP","in_stock":true},{"title":"16C","offer_id":56997126078846,"sku":"AMR116C-030","price":8.59,"currency_code":"GBP","in_stock":true},{"title":"20C","offer_id":56997126111614,"sku":"AMR120C-030","price":8.59,"currency_code":"GBP","in_stock":true},{"title":"25C","offer_id":56997126144382,"sku":"AMR125C-030","price":8.59,"currency_code":"GBP","in_stock":true},{"title":"32C","offer_id":56997126177150,"sku":"AMR132C-030","price":8.59,"currency_code":"GBP","in_stock":true},{"title":"40C","offer_id":56997126209918,"sku":"AMR140C-030","price":8.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/Switched_Neutral_Type_A_RCBO_30mA_6kA.png?v=1772315272"},{"product_id":"excel-6-module-main-switch-consumer-unit-with-type-2-spd-uk","title":"Excel E0602S Main Switch Consumer Unit with Type 2 SPD","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-66\" data-testid=\"conversation-turn-22\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"8909cfb1-589a-4811-bbb8-9c77a9dbe057\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"336\" data-end=\"349\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"350\" data-end=\"759\"\u003eThe Excel E0602S Main Switch Consumer Unit with Type 2 SPD is a compact and reliable electrical distribution solution designed for modern residential and light commercial installations. Featuring a 6-module enclosure with 2 usable ways, it provides efficient circuit control while maintaining a space-saving design. This unit is ideal for installations where safety, simplicity, and performance are essential.\u003c\/p\u003e\n\u003cp data-start=\"761\" data-end=\"1075\"\u003eEquipped with a 100A main switch and integrated Type 2 Surge Protection Device (SPD), it offers enhanced protection against electrical surges and voltage spikes. The inclusion of a 32A MCB ensures dependable circuit control, making it a complete and ready-to-install solution for secure power distribution systems.\u003c\/p\u003e\n\u003chr data-start=\"1077\" data-end=\"1080\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1082\" data-end=\"1099\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1100\" data-end=\"1507\"\u003e\n\u003cli data-section-id=\"6tydg\" data-start=\"1100\" data-end=\"1141\"\u003e6-module compact consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"1jxrf3b\" data-start=\"1142\" data-end=\"1194\"\u003e2 usable ways for flexible circuit configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1m8x82p\" data-start=\"1195\" data-end=\"1229\"\u003eSupplied with 100A main switch\u003c\/li\u003e\n\u003cli data-section-id=\"171td8e\" data-start=\"1230\" data-end=\"1281\"\u003eIntegrated Type 2 Surge Protection Device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"zdiebk\" data-start=\"1282\" data-end=\"1325\"\u003eIncludes 32A MCB for circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"o73qyh\" data-start=\"1326\" data-end=\"1370\"\u003eSpace-saving and modern enclosure design\u003c\/li\u003e\n\u003cli data-section-id=\"1gkt1yy\" data-start=\"1371\" data-end=\"1424\"\u003eSuitable for residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"aoijeg\" data-start=\"1425\" data-end=\"1469\"\u003eEnhanced protection against power surges\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1470\" data-end=\"1507\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1509\" data-end=\"1512\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1514\" data-end=\"1543\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1544\" data-end=\"1793\"\u003e\n\u003cli data-section-id=\"d8478t\" data-start=\"1544\" data-end=\"1559\"\u003eSKU: E0602S\u003c\/li\u003e\n\u003cli data-section-id=\"l7q7l3\" data-start=\"1560\" data-end=\"1584\"\u003eNumber of Modules: 6\u003c\/li\u003e\n\u003cli data-section-id=\"1l5z5o0\" data-start=\"1585\" data-end=\"1603\"\u003eUsable Ways: 2\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1604\" data-end=\"1632\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"1633\" data-end=\"1652\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"44huyy\" data-start=\"1653\" data-end=\"1685\"\u003eSurge Protection: Type 2 SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1k93tor\" data-start=\"1686\" data-end=\"1721\"\u003eType: Main Switch Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"1epfsdf\" data-start=\"1722\" data-end=\"1793\"\u003eApplication: Residential \/ Light Commercial Electrical Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1795\" data-end=\"1798\"\u003e\n\u003ch2 data-section-id=\"141h6ea\" data-start=\"1800\" data-end=\"1844\"\u003eWhy Choose a Excel E0602S Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1845\" data-end=\"2085\"\u003eThe Excel E0602S consumer unit is an excellent choice for users seeking a compact yet highly protective electrical distribution solution. Its integrated SPD ensures sensitive electrical equipment is safeguarded from unexpected power surges.\u003c\/p\u003e\n\u003cp data-start=\"2087\" data-end=\"2337\"\u003eWith its simple layout, durable construction, and pre-installed protective components, this unit reduces installation time while improving system safety. It is a reliable option for modern electrical installations requiring efficiency and compliance.\u003c\/p\u003e\n\u003chr data-start=\"2339\" data-end=\"2342\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2344\" data-end=\"2353\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2355\" data-end=\"2512\"\u003e\u003cstrong data-start=\"2355\" data-end=\"2410\"\u003e1. What is the main function of this consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"2410\" data-end=\"2413\"\u003eIt provides safe and controlled distribution of electrical power with built-in protection features.\u003c\/p\u003e\n\u003cp data-start=\"2514\" data-end=\"2622\"\u003e\u003cstrong data-start=\"2514\" data-end=\"2554\"\u003e2. Does it include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2554\" data-end=\"2557\"\u003eYes, it comes with an integrated Type 2 SPD for surge protection.\u003c\/p\u003e\n\u003cp data-start=\"2624\" data-end=\"2716\"\u003e\u003cstrong data-start=\"2624\" data-end=\"2664\"\u003e3. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2664\" data-end=\"2667\"\u003eIt offers 2 usable ways within a 6-module design.\u003c\/p\u003e\n\u003cp data-start=\"2718\" data-end=\"2833\"\u003e\u003cstrong data-start=\"2718\" data-end=\"2763\"\u003e4. Is it suitable for home installations?\u003c\/strong\u003e\u003cbr data-start=\"2763\" data-end=\"2766\"\u003eYes, it is ideal for residential and light commercial applications.\u003c\/p\u003e\n\u003cp data-start=\"2835\" data-end=\"2939\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2835\" data-end=\"2878\"\u003e5. What main switch rating is included?\u003c\/strong\u003e\u003cbr data-start=\"2878\" data-end=\"2881\"\u003eIt includes a 100A main switch for reliable power control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57271804756350,"sku":null,"price":44.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E0602S-side.png?v=1776448593"},{"product_id":"excel-e1006s-10-module-main-switch-consumer-unit-with-spd-uk","title":"Excel E1006S 10 Module Main Switch Consumer Unit with SPD UK","description":"\u003cdiv class=\"flex flex-col text-sm\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-65\" data-testid=\"conversation-turn-24\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"9c528313-d2c2-4bb5-b66d-eeadfc7e974c\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"359\" data-end=\"372\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"373\" data-end=\"752\"\u003eThe Excel Distribution Board E1006S 10 Module Main Switch Consumer Unit is a compact and reliable electrical distribution solution designed for modern residential and light commercial installations. Featuring 6 usable ways within a 10-module enclosure, it provides efficient circuit management while maintaining a space-saving design ideal for upgraded or new electrical systems.\u003c\/p\u003e\n\u003cp data-start=\"754\" data-end=\"1102\"\u003eEquipped with a 100A main switch and integrated Type 2 Surge Protection Device (SPD), this consumer unit ensures enhanced protection against overloads and voltage surges. The inclusion of a 32A MCB further improves circuit safety, making it a dependable choice for safeguarding sensitive electrical equipment and ensuring stable power distribution.\u003c\/p\u003e\n\u003chr data-start=\"1104\" data-end=\"1107\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1109\" data-end=\"1126\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1127\" data-end=\"1633\"\u003e\n\u003cli data-section-id=\"1xaigx0\" data-start=\"1127\" data-end=\"1182\"\u003e10-module consumer unit with 6 usable outgoing ways\u003c\/li\u003e\n\u003cli data-section-id=\"5eyg1y\" data-start=\"1183\" data-end=\"1240\"\u003eSupplied with 100A main switch for reliable isolation\u003c\/li\u003e\n\u003cli data-section-id=\"171td8e\" data-start=\"1241\" data-end=\"1292\"\u003eIntegrated Type 2 Surge Protection Device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"5tdrq8\" data-start=\"1293\" data-end=\"1342\"\u003eIncludes 32A MCB for added circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"jec1rg\" data-start=\"1343\" data-end=\"1405\"\u003eCompact design suitable for space-restricted installations\u003c\/li\u003e\n\u003cli data-section-id=\"fie37t\" data-start=\"1406\" data-end=\"1464\"\u003eStrong and durable enclosure for long-term performance\u003c\/li\u003e\n\u003cli data-section-id=\"1hye750\" data-start=\"1465\" data-end=\"1524\"\u003eIdeal for residential and light commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"1hnx2ci\" data-start=\"1525\" data-end=\"1578\"\u003eEfficient internal layout for easier installation\u003c\/li\u003e\n\u003cli data-section-id=\"1dg1zmp\" data-start=\"1579\" data-end=\"1633\"\u003eDesigned for modern electrical safety requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1635\" data-end=\"1638\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1640\" data-end=\"1669\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1670\" data-end=\"1909\"\u003e\n\u003cli data-section-id=\"hi38zw\" data-start=\"1670\" data-end=\"1687\"\u003eModel: E1006S\u003c\/li\u003e\n\u003cli data-section-id=\"1s51d9o\" data-start=\"1688\" data-end=\"1707\"\u003eModule Size: 10\u003c\/li\u003e\n\u003cli data-section-id=\"1l5z910\" data-start=\"1708\" data-end=\"1726\"\u003eUsable Ways: 6\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1727\" data-end=\"1755\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"44huyy\" data-start=\"1756\" data-end=\"1788\"\u003eSurge Protection: Type 2 SPD\u003c\/li\u003e\n\u003cli data-section-id=\"uvwtdx\" data-start=\"1789\" data-end=\"1821\"\u003eIncluded Protection: 32A MCB\u003c\/li\u003e\n\u003cli data-section-id=\"8gbs3b\" data-start=\"1822\" data-end=\"1869\"\u003eApplication: Residential \/ Light Commercial\u003c\/li\u003e\n\u003cli data-section-id=\"1j3ewvt\" data-start=\"1870\" data-end=\"1909\"\u003eEnclosure Type: Metal consumer unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1911\" data-end=\"1914\"\u003e\n\u003ch2 data-section-id=\"u0ko2s\" data-start=\"1916\" data-end=\"1969\"\u003eWhy Choose a Excel E1006S Consumer Unit with SPD\u003c\/h2\u003e\n\u003cp data-start=\"1970\" data-end=\"2281\"\u003eThe Excel E1006S consumer unit is designed to deliver reliable performance in a compact footprint, making it ideal for installations where space efficiency and safety are essential. Its integrated surge protection helps prevent damage caused by electrical spikes, improving the lifespan of connected appliances.\u003c\/p\u003e\n\u003cp data-start=\"2283\" data-end=\"2518\"\u003eWith a user-friendly layout and robust construction, it offers quick installation and long-term dependability. This makes it a practical choice for electricians and installers working on modern residential or light commercial projects.\u003c\/p\u003e\n\u003chr data-start=\"2520\" data-end=\"2523\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2525\" data-end=\"2534\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2536\" data-end=\"2659\"\u003e\u003cstrong data-start=\"2536\" data-end=\"2572\"\u003e1. What does 6 usable ways mean?\u003c\/strong\u003e\u003cbr data-start=\"2572\" data-end=\"2575\"\u003eIt means the unit can support up to 6 outgoing circuits for electrical distribution.\u003c\/p\u003e\n\u003cp data-start=\"2661\" data-end=\"2795\"\u003e\u003cstrong data-start=\"2661\" data-end=\"2717\"\u003e2. Does this consumer unit include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2717\" data-end=\"2720\"\u003eYes, it includes a built-in Type 2 SPD for protection against power surges.\u003c\/p\u003e\n\u003cp data-start=\"2797\" data-end=\"2906\"\u003e\u003cstrong data-start=\"2797\" data-end=\"2842\"\u003e3. Is it suitable for home installations?\u003c\/strong\u003e\u003cbr data-start=\"2842\" data-end=\"2845\"\u003eYes, it is designed for residential and light commercial use.\u003c\/p\u003e\n\u003cp data-start=\"2908\" data-end=\"3012\"\u003e\u003cstrong data-start=\"2908\" data-end=\"2946\"\u003e4. What is the main switch rating?\u003c\/strong\u003e\u003cbr data-start=\"2946\" data-end=\"2949\"\u003eIt comes with a 100A main switch for safe electrical isolation.\u003c\/p\u003e\n\u003cp data-start=\"3014\" data-end=\"3129\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3014\" data-end=\"3060\"\u003e5. What additional protection is included?\u003c\/strong\u003e\u003cbr data-start=\"3060\" data-end=\"3063\"\u003eIt includes a 32A MCB for enhanced circuit safety and reliability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272280711550,"sku":null,"price":47.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E1006S-side.png?v=1776455941"},{"product_id":"excel-e1410s-main-switch-consumer-unit-with-type-2-spd","title":"Excel E1410S Main Switch Consumer Unit with Type 2 SPD","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-67\" data-testid=\"conversation-turn-24\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"170d9033-cdd4-48c0-9e07-136d2aa5fe07\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"335\" data-end=\"348\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"349\" data-end=\"782\"\u003eThe Excel E1410S Main Switch Consumer Unit with Type 2 SPD is a high-performance and compact electrical distribution solution designed for modern residential and light commercial installations. Featuring a 14-module enclosure with 10 usable ways, it provides excellent flexibility for circuit arrangement while maintaining a neat and organized setup. Its design ensures safe and efficient power distribution across multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"784\" data-end=\"1117\"\u003eEquipped with a 100A main switch and integrated Type 2 Surge Protection Device (SPD), this consumer unit offers enhanced protection against electrical surges and transient voltage spikes. The included 32A MCB adds reliable circuit protection, making it a complete and ready-to-install solution for safe and stable electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"1119\" data-end=\"1122\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1124\" data-end=\"1141\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1142\" data-end=\"1558\"\u003e\n\u003cli data-section-id=\"1e6h2s1\" data-start=\"1142\" data-end=\"1189\"\u003e14-module consumer unit with 10 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1m8x82p\" data-start=\"1190\" data-end=\"1224\"\u003eSupplied with 100A main switch\u003c\/li\u003e\n\u003cli data-section-id=\"171td8e\" data-start=\"1225\" data-end=\"1276\"\u003eIntegrated Type 2 Surge Protection Device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"zdiebk\" data-start=\"1277\" data-end=\"1320\"\u003eIncludes 32A MCB for circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1bdd9s6\" data-start=\"1321\" data-end=\"1359\"\u003eCompact and space-efficient design\u003c\/li\u003e\n\u003cli data-section-id=\"1s3haq8\" data-start=\"1360\" data-end=\"1422\"\u003eSuitable for residential and light commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"1axud51\" data-start=\"1423\" data-end=\"1469\"\u003eEnhanced protection against voltage surges\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1470\" data-end=\"1507\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"cqmrlq\" data-start=\"1508\" data-end=\"1558\"\u003eDurable construction for long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1560\" data-end=\"1563\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1565\" data-end=\"1594\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1595\" data-end=\"1840\"\u003e\n\u003cli data-section-id=\"1tgrvvx\" data-start=\"1595\" data-end=\"1610\"\u003eSKU: E1410S\u003c\/li\u003e\n\u003cli data-section-id=\"1osu1g4\" data-start=\"1611\" data-end=\"1636\"\u003eNumber of Modules: 14\u003c\/li\u003e\n\u003cli data-section-id=\"13oe76r\" data-start=\"1637\" data-end=\"1656\"\u003eUsable Ways: 10\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1657\" data-end=\"1685\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"1686\" data-end=\"1705\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"44huyy\" data-start=\"1706\" data-end=\"1738\"\u003eSurge Protection: Type 2 SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1k93tor\" data-start=\"1739\" data-end=\"1774\"\u003eType: Main Switch Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1775\" data-end=\"1840\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1842\" data-end=\"1845\"\u003e\n\u003ch2 data-section-id=\"bpd9k2\" data-start=\"1847\" data-end=\"1891\"\u003eWhy Choose a Excel E1410S Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1892\" data-end=\"2127\"\u003eThe Excel E1410S consumer unit is designed for users who require a balance of capacity, safety, and efficiency. Its integrated SPD protects valuable electrical equipment from sudden voltage spikes, ensuring improved system reliability.\u003c\/p\u003e\n\u003cp data-start=\"2129\" data-end=\"2383\"\u003eWith its 10 usable ways and compact 14-module layout, it offers flexibility for expanding electrical circuits. Combined with durable construction and user-friendly installation features, it is a dependable choice for modern electrical distribution needs.\u003c\/p\u003e\n\u003chr data-start=\"2385\" data-end=\"2388\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2390\" data-end=\"2399\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2401\" data-end=\"2546\"\u003e\u003cstrong data-start=\"2401\" data-end=\"2455\"\u003e1. What is the main purpose of this consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"2455\" data-end=\"2458\"\u003eIt provides safe electrical distribution with built-in protection for multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"2548\" data-end=\"2673\"\u003e\u003cstrong data-start=\"2548\" data-end=\"2588\"\u003e2. Does it include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2588\" data-end=\"2591\"\u003eYes, it comes with an integrated Type 2 SPD for protection against voltage surges.\u003c\/p\u003e\n\u003cp data-start=\"2675\" data-end=\"2770\"\u003e\u003cstrong data-start=\"2675\" data-end=\"2716\"\u003e3. How many usable ways does it have?\u003c\/strong\u003e\u003cbr data-start=\"2716\" data-end=\"2719\"\u003eIt has 10 usable ways within a 14-module enclosure.\u003c\/p\u003e\n\u003cp data-start=\"2772\" data-end=\"2878\"\u003e\u003cstrong data-start=\"2772\" data-end=\"2807\"\u003e4. Is it suitable for home use?\u003c\/strong\u003e\u003cbr data-start=\"2807\" data-end=\"2810\"\u003eYes, it is ideal for residential and light commercial installations.\u003c\/p\u003e\n\u003cp data-start=\"2880\" data-end=\"2992\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2880\" data-end=\"2921\"\u003e5. What main components are included?\u003c\/strong\u003e\u003cbr data-start=\"2921\" data-end=\"2924\"\u003eIt includes a 100A main switch and a 32A MCB for circuit protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272361222526,"sku":null,"price":53.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E1410S-side.png?v=1776456822"},{"product_id":"excel-e1814s-main-switch-consumer-unit-with-type-2-spd","title":"Excel E1814S Main Switch Consumer Unit with Type 2 SPD","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-69\" data-testid=\"conversation-turn-26\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"fb67ff0e-7774-46ac-87cf-79c4ac4d733d\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"335\" data-end=\"348\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"349\" data-end=\"815\"\u003eThe Excel E1814S Main Switch Consumer Unit with Type 2 SPD is a robust and efficient electrical distribution solution designed for modern residential and light commercial installations. With an 18-module enclosure offering 14 usable ways, it provides excellent flexibility for managing multiple circuits while maintaining a neat and organized layout. This makes it ideal for installations requiring higher circuit capacity without compromising safety or performance.\u003c\/p\u003e\n\u003cp data-start=\"817\" data-end=\"1162\"\u003eEquipped with a 100A main switch and integrated Type 2 Surge Protection Device (SPD), this consumer unit delivers strong protection against voltage spikes and electrical surges. The inclusion of a 32A MCB ensures reliable circuit control, making it a complete and ready-to-install solution for safe and efficient electrical distribution systems.\u003c\/p\u003e\n\u003chr data-start=\"1164\" data-end=\"1167\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1169\" data-end=\"1186\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1187\" data-end=\"1586\"\u003e\n\u003cli data-section-id=\"1ijhuqh\" data-start=\"1187\" data-end=\"1234\"\u003e18-module consumer unit with 14 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1m8x82p\" data-start=\"1235\" data-end=\"1269\"\u003eSupplied with 100A main switch\u003c\/li\u003e\n\u003cli data-section-id=\"171td8e\" data-start=\"1270\" data-end=\"1321\"\u003eIntegrated Type 2 Surge Protection Device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"zdiebk\" data-start=\"1322\" data-end=\"1365\"\u003eIncludes 32A MCB for circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"15w6ama\" data-start=\"1366\" data-end=\"1402\"\u003eCompact yet high-capacity design\u003c\/li\u003e\n\u003cli data-section-id=\"1gkt1yy\" data-start=\"1403\" data-end=\"1456\"\u003eSuitable for residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"1ppqbs9\" data-start=\"1457\" data-end=\"1506\"\u003eEnhanced protection against electrical surges\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1507\" data-end=\"1544\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1545\" data-end=\"1586\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1588\" data-end=\"1591\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1593\" data-end=\"1622\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1623\" data-end=\"1868\"\u003e\n\u003cli data-section-id=\"1lp9a1x\" data-start=\"1623\" data-end=\"1638\"\u003eSKU: E1814S\u003c\/li\u003e\n\u003cli data-section-id=\"1osu4t4\" data-start=\"1639\" data-end=\"1664\"\u003eNumber of Modules: 18\u003c\/li\u003e\n\u003cli data-section-id=\"13oeajr\" data-start=\"1665\" data-end=\"1684\"\u003eUsable Ways: 14\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1685\" data-end=\"1713\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"1714\" data-end=\"1733\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"44huyy\" data-start=\"1734\" data-end=\"1766\"\u003eSurge Protection: Type 2 SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1k93tor\" data-start=\"1767\" data-end=\"1802\"\u003eType: Main Switch Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1803\" data-end=\"1868\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1870\" data-end=\"1873\"\u003e\n\u003ch2 data-section-id=\"hfxn6y\" data-start=\"1875\" data-end=\"1919\"\u003eWhy Choose a Excel E1814S Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1920\" data-end=\"2156\"\u003eThe Excel E1814S consumer unit is designed for users who need a higher-capacity yet compact electrical distribution solution. Its integrated SPD ensures reliable protection for sensitive electrical equipment against sudden power surges.\u003c\/p\u003e\n\u003cp data-start=\"2158\" data-end=\"2422\"\u003eWith 14 usable ways and a thoughtfully designed 18-module layout, it offers flexibility for future expansion and efficient circuit management. Combined with its durable build and safety-focused design, it is a dependable choice for modern electrical installations.\u003c\/p\u003e\n\u003chr data-start=\"2424\" data-end=\"2427\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2429\" data-end=\"2438\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2440\" data-end=\"2586\"\u003e\u003cstrong data-start=\"2440\" data-end=\"2494\"\u003e1. What is the main purpose of this consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"2494\" data-end=\"2497\"\u003eIt provides safe and organized electrical distribution with built-in protection features.\u003c\/p\u003e\n\u003cp data-start=\"2588\" data-end=\"2713\"\u003e\u003cstrong data-start=\"2588\" data-end=\"2628\"\u003e2. Does it include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2628\" data-end=\"2631\"\u003eYes, it comes with an integrated Type 2 SPD for protection against voltage surges.\u003c\/p\u003e\n\u003cp data-start=\"2715\" data-end=\"2817\"\u003e\u003cstrong data-start=\"2715\" data-end=\"2757\"\u003e3. How many usable ways does it offer?\u003c\/strong\u003e\u003cbr data-start=\"2757\" data-end=\"2760\"\u003eIt provides 14 usable ways within an 18-module enclosure.\u003c\/p\u003e\n\u003cp data-start=\"2819\" data-end=\"2925\"\u003e\u003cstrong data-start=\"2819\" data-end=\"2861\"\u003e4. Is it suitable for residential use?\u003c\/strong\u003e\u003cbr data-start=\"2861\" data-end=\"2864\"\u003eYes, it is ideal for homes and light commercial applications.\u003c\/p\u003e\n\u003cp data-start=\"2927\" data-end=\"3051\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2927\" data-end=\"2971\"\u003e5. What protective devices are included?\u003c\/strong\u003e\u003cbr data-start=\"2971\" data-end=\"2974\"\u003eIt includes a 100A main switch and a 32A MCB for reliable circuit protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272383340926,"sku":null,"price":59.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-36.png?v=1776457333"},{"product_id":"excel-e2420s-main-switch-consumer-unit-with-type-2-spd","title":"Excel E2420S Main Switch Consumer Unit with Type 2 SPD","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-71\" data-testid=\"conversation-turn-28\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"a978318f-ef70-4324-8ce7-9694fb3e706f\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"339\" data-end=\"352\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"353\" data-end=\"725\"\u003eThe Excel E2420S Main Switch Consumer Unit with Type 2 SPD is a high-capacity and reliable electrical distribution solution designed for modern residential and light commercial installations. Featuring a 24-module enclosure with 20 usable ways, it provides exceptional flexibility for managing multiple circuits while maintaining a clean and organized installation layout.\u003c\/p\u003e\n\u003cp data-start=\"727\" data-end=\"1075\"\u003eEquipped with a 100A main switch and integrated Type 2 Surge Protection Device (SPD), this consumer unit delivers advanced protection against electrical surges and voltage spikes. The inclusion of a 32A MCB ensures stable and secure circuit control, making it a complete and efficient solution for safe power distribution in demanding environments.\u003c\/p\u003e\n\u003chr data-start=\"1077\" data-end=\"1080\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1082\" data-end=\"1099\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1100\" data-end=\"1503\"\u003e\n\u003cli data-section-id=\"1bzqo6p\" data-start=\"1100\" data-end=\"1147\"\u003e24-module consumer unit with 20 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1m8x82p\" data-start=\"1148\" data-end=\"1182\"\u003eSupplied with 100A main switch\u003c\/li\u003e\n\u003cli data-section-id=\"171td8e\" data-start=\"1183\" data-end=\"1234\"\u003eIntegrated Type 2 Surge Protection Device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"zdiebk\" data-start=\"1235\" data-end=\"1278\"\u003eIncludes 32A MCB for circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"6x22ba\" data-start=\"1279\" data-end=\"1328\"\u003eHigh-capacity design for larger installations\u003c\/li\u003e\n\u003cli data-section-id=\"1gkt1yy\" data-start=\"1329\" data-end=\"1382\"\u003eSuitable for residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"aoijeg\" data-start=\"1383\" data-end=\"1427\"\u003eEnhanced protection against power surges\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1428\" data-end=\"1465\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"we2nzj\" data-start=\"1466\" data-end=\"1503\"\u003eDurable and reliable construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1505\" data-end=\"1508\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1510\" data-end=\"1539\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1540\" data-end=\"1785\"\u003e\n\u003cli data-section-id=\"16vdvvx\" data-start=\"1540\" data-end=\"1555\"\u003eSKU: E2420S\u003c\/li\u003e\n\u003cli data-section-id=\"1osxugn\" data-start=\"1556\" data-end=\"1581\"\u003eNumber of Modules: 24\u003c\/li\u003e\n\u003cli data-section-id=\"13oae68\" data-start=\"1582\" data-end=\"1601\"\u003eUsable Ways: 20\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1602\" data-end=\"1630\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"1631\" data-end=\"1650\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"44huyy\" data-start=\"1651\" data-end=\"1683\"\u003eSurge Protection: Type 2 SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1k93tor\" data-start=\"1684\" data-end=\"1719\"\u003eType: Main Switch Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1720\" data-end=\"1785\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1787\" data-end=\"1790\"\u003e\n\u003ch2 data-section-id=\"5phq5e\" data-start=\"1792\" data-end=\"1836\"\u003eWhy Choose a Excel E2420S Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1837\" data-end=\"2107\"\u003eThe Excel E2420S consumer unit is ideal for installations requiring maximum circuit capacity combined with reliable surge protection. Its integrated SPD helps safeguard electrical systems and connected devices from sudden voltage spikes, improving overall system safety.\u003c\/p\u003e\n\u003cp data-start=\"2109\" data-end=\"2389\"\u003eWith 20 usable ways and a spacious 24-module design, it offers excellent flexibility for future expansion and complex wiring setups. Its durable construction and user-friendly design make it a dependable choice for modern electrical installations requiring performance and safety.\u003c\/p\u003e\n\u003chr data-start=\"2391\" data-end=\"2394\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2396\" data-end=\"2405\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2407\" data-end=\"2549\"\u003e\u003cstrong data-start=\"2407\" data-end=\"2463\"\u003e1. What is the main advantage of this consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"2463\" data-end=\"2466\"\u003eIt offers high circuit capacity with built-in surge protection for improved safety.\u003c\/p\u003e\n\u003cp data-start=\"2551\" data-end=\"2638\"\u003e\u003cstrong data-start=\"2551\" data-end=\"2591\"\u003e2. Does it include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2591\" data-end=\"2594\"\u003eYes, it comes with an integrated Type 2 SPD.\u003c\/p\u003e\n\u003cp data-start=\"2640\" data-end=\"2741\"\u003e\u003cstrong data-start=\"2640\" data-end=\"2682\"\u003e3. How many usable ways are available?\u003c\/strong\u003e\u003cbr data-start=\"2682\" data-end=\"2685\"\u003eIt provides 20 usable ways within a 24-module enclosure.\u003c\/p\u003e\n\u003cp data-start=\"2743\" data-end=\"2888\"\u003e\u003cstrong data-start=\"2743\" data-end=\"2799\"\u003e4. Is it suitable for large homes or commercial use?\u003c\/strong\u003e\u003cbr data-start=\"2799\" data-end=\"2802\"\u003eYes, it is ideal for larger residential properties and light commercial installations.\u003c\/p\u003e\n\u003cp data-start=\"2890\" data-end=\"3006\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2890\" data-end=\"2934\"\u003e5. What protective devices are included?\u003c\/strong\u003e\u003cbr data-start=\"2934\" data-end=\"2937\"\u003eIt includes a 100A main switch and a 32A MCB for reliable protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272411685246,"sku":null,"price":65.13,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E2418S-side.png?v=1776457617"},{"product_id":"excel-e2823s-28-module-dual-stack-consumer-unit-with-spd","title":"Excel E2823S 28 Module Dual Stack Consumer Unit with SPD","description":"\u003ch2 data-section-id=\"6lznae\" data-start=\"333\" data-end=\"346\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"347\" data-end=\"724\"\u003eThe Excel E2823S 28 Module Dual Stack Consumer Unit is a high-capacity and professionally engineered electrical distribution solution designed for modern residential and light commercial installations. With 23 usable ways, it offers excellent flexibility for managing multiple circuits while maintaining a compact and structured dual-stack design that saves installation space.\u003c\/p\u003e\n\u003cp data-start=\"726\" data-end=\"1069\"\u003eEquipped with a 100A main switch and integrated Type 2 Surge Protection Device (SPD), this consumer unit ensures enhanced protection against electrical surges and voltage spikes. The inclusion of a 32A MCB provides reliable circuit control, making it a complete, safe, and efficient solution for demanding electrical distribution requirements.\u003c\/p\u003e\n\u003chr data-start=\"1071\" data-end=\"1074\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1076\" data-end=\"1093\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1094\" data-end=\"1542\"\u003e\n\u003cli data-section-id=\"1aculy\" data-start=\"1094\" data-end=\"1151\"\u003e28-module dual stack design for efficient space usage\u003c\/li\u003e\n\u003cli data-section-id=\"6iihry\" data-start=\"1152\" data-end=\"1204\"\u003e23 usable ways for flexible circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1m8x82p\" data-start=\"1205\" data-end=\"1239\"\u003eSupplied with 100A main switch\u003c\/li\u003e\n\u003cli data-section-id=\"171td8e\" data-start=\"1240\" data-end=\"1291\"\u003eIntegrated Type 2 Surge Protection Device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"zdiebk\" data-start=\"1292\" data-end=\"1335\"\u003eIncludes 32A MCB for circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"yst17h\" data-start=\"1336\" data-end=\"1387\"\u003eHigh-capacity solution for larger installations\u003c\/li\u003e\n\u003cli data-section-id=\"1s3haq8\" data-start=\"1388\" data-end=\"1450\"\u003eSuitable for residential and light commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"1ppqbs9\" data-start=\"1451\" data-end=\"1500\"\u003eEnhanced protection against electrical surges\u003c\/li\u003e\n\u003cli data-section-id=\"pfdqec\" data-start=\"1501\" data-end=\"1542\"\u003eDurable and installer-friendly design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1544\" data-end=\"1547\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1549\" data-end=\"1578\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1579\" data-end=\"1823\"\u003e\n\u003cli data-section-id=\"z3rh1e\" data-start=\"1579\" data-end=\"1594\"\u003eSKU: E2823S\u003c\/li\u003e\n\u003cli data-section-id=\"1osxxtn\" data-start=\"1595\" data-end=\"1620\"\u003eNumber of Modules: 28\u003c\/li\u003e\n\u003cli data-section-id=\"13oaf2b\" data-start=\"1621\" data-end=\"1640\"\u003eUsable Ways: 23\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1641\" data-end=\"1669\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"1670\" data-end=\"1689\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"44huyy\" data-start=\"1690\" data-end=\"1722\"\u003eSurge Protection: Type 2 SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1yg380w\" data-start=\"1723\" data-end=\"1757\"\u003eType: Dual Stack Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1758\" data-end=\"1823\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1825\" data-end=\"1828\"\u003e\n\u003ch2 data-section-id=\"8nzbyl\" data-start=\"1830\" data-end=\"1874\"\u003eWhy Choose a Excel E2823S Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1875\" data-end=\"2143\"\u003eThe Excel E2823S consumer unit is ideal for installations requiring high circuit capacity combined with compact design efficiency. Its dual-stack configuration allows more circuits to be managed in a reduced footprint, making it suitable for modern electrical layouts.\u003c\/p\u003e\n\u003cp data-start=\"2145\" data-end=\"2381\"\u003eWith integrated surge protection and robust construction, it delivers long-term reliability and safety. It is a dependable choice for electricians and installers who require a powerful, organized, and future-ready distribution solution.\u003c\/p\u003e\n\u003chr data-start=\"2383\" data-end=\"2386\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2388\" data-end=\"2397\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2399\" data-end=\"2539\"\u003e\u003cstrong data-start=\"2399\" data-end=\"2441\"\u003e1. What is a dual stack consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"2441\" data-end=\"2444\"\u003eIt is a compact design that stacks circuits vertically to save space while increasing capacity.\u003c\/p\u003e\n\u003cp data-start=\"2541\" data-end=\"2617\"\u003e\u003cstrong data-start=\"2541\" data-end=\"2581\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2581\" data-end=\"2584\"\u003eIt supports up to 23 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2619\" data-end=\"2744\"\u003e\u003cstrong data-start=\"2619\" data-end=\"2659\"\u003e3. Does it include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2659\" data-end=\"2662\"\u003eYes, it comes with an integrated Type 2 SPD for protection against voltage spikes.\u003c\/p\u003e\n\u003cp data-start=\"2746\" data-end=\"2859\"\u003e\u003cstrong data-start=\"2746\" data-end=\"2784\"\u003e4. Is it suitable for large homes?\u003c\/strong\u003e\u003cbr data-start=\"2784\" data-end=\"2787\"\u003eYes, it is ideal for larger residential and light commercial properties.\u003c\/p\u003e\n\u003cp data-start=\"2861\" data-end=\"2958\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2861\" data-end=\"2910\"\u003e5. What main protection devices are included?\u003c\/strong\u003e\u003cbr data-start=\"2910\" data-end=\"2913\"\u003eIt includes a 100A main switch and a 32A MCB.\u003c\/p\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272426004862,"sku":null,"price":101.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-54.png?v=1776457917"},{"product_id":"excel-e0604-main-switch-incomer-consumer-unit-6-module-4-way","title":"Excel E0604 Main Switch Incomer Consumer Unit 6 Module 4 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-73\" data-testid=\"conversation-turn-32\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"eaa8a26c-9fc2-4fdc-af57-ab651f41fea6\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"351\" data-end=\"364\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"365\" data-end=\"686\"\u003eThe Excel E0604 Main Switch Incomer Consumer Unit is a compact and efficient electrical distribution solution designed for residential and small-scale installations. With a 6-module enclosure and 4 usable ways, it provides a practical setup for managing multiple circuits while maintaining a neat and space-saving design.\u003c\/p\u003e\n\u003cp data-start=\"688\" data-end=\"1003\"\u003eEquipped with a 100A main switch incomer, this consumer unit ensures reliable control and isolation of electrical supply. Its straightforward configuration and durable construction make it an ideal choice for electricians seeking a dependable and easy-to-install solution for everyday electrical distribution needs.\u003c\/p\u003e\n\u003chr data-start=\"1005\" data-end=\"1008\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1010\" data-end=\"1027\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1028\" data-end=\"1414\"\u003e\n\u003cli data-section-id=\"6tydg\" data-start=\"1028\" data-end=\"1069\"\u003e6-module compact consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"c0fdhn\" data-start=\"1070\" data-end=\"1121\"\u003e4 usable ways for flexible circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"18lhnlc\" data-start=\"1122\" data-end=\"1164\"\u003eSupplied with 100A main switch incomer\u003c\/li\u003e\n\u003cli data-section-id=\"1a05x04\" data-start=\"1165\" data-end=\"1210\"\u003eIdeal for small residential installations\u003c\/li\u003e\n\u003cli data-section-id=\"1jbmzk7\" data-start=\"1211\" data-end=\"1251\"\u003eSpace-saving and practical enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1252\" data-end=\"1289\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1290\" data-end=\"1331\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003cli data-section-id=\"1lsoc05\" data-start=\"1332\" data-end=\"1374\"\u003eSuitable for modern electrical systems\u003c\/li\u003e\n\u003cli data-section-id=\"1dk7x0c\" data-start=\"1375\" data-end=\"1414\"\u003eClean and organized internal layout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1416\" data-end=\"1419\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1421\" data-end=\"1450\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1451\" data-end=\"1646\"\u003e\n\u003cli data-section-id=\"woqyew\" data-start=\"1451\" data-end=\"1465\"\u003eSKU: E0604\u003c\/li\u003e\n\u003cli data-section-id=\"l7q7l3\" data-start=\"1466\" data-end=\"1490\"\u003eNumber of Modules: 6\u003c\/li\u003e\n\u003cli data-section-id=\"1l5zapi\" data-start=\"1491\" data-end=\"1509\"\u003eUsable Ways: 4\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1510\" data-end=\"1538\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"d9xjwa\" data-start=\"1539\" data-end=\"1582\"\u003eType: Main Switch Incomer Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"fi8irz\" data-start=\"1583\" data-end=\"1646\"\u003eApplication: Residential and Small Electrical Installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1648\" data-end=\"1651\"\u003e\n\u003ch2 data-section-id=\"nm307r\" data-start=\"1653\" data-end=\"1696\"\u003eWhy Choose a Excel E0604 Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1697\" data-end=\"1935\"\u003eThe Excel E0604 consumer unit is perfect for installations where space is limited but reliable performance is essential. Its compact design allows for easy placement while still offering sufficient capacity for basic circuit distribution.\u003c\/p\u003e\n\u003cp data-start=\"1937\" data-end=\"2194\"\u003eWith a robust 100A main switch and user-friendly layout, it simplifies installation and ensures dependable operation. It is a practical and cost-effective choice for electricians and homeowners looking for a straightforward electrical distribution solution.\u003c\/p\u003e\n\u003chr data-start=\"2196\" data-end=\"2199\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2201\" data-end=\"2210\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2212\" data-end=\"2375\"\u003e\u003cstrong data-start=\"2212\" data-end=\"2280\"\u003e1. What type of installation is this consumer unit suitable for?\u003c\/strong\u003e\u003cbr data-start=\"2280\" data-end=\"2283\"\u003eIt is ideal for small residential setups or installations with limited circuit requirements.\u003c\/p\u003e\n\u003cp data-start=\"2377\" data-end=\"2452\"\u003e\u003cstrong data-start=\"2377\" data-end=\"2417\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2417\" data-end=\"2420\"\u003eIt supports up to 4 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2454\" data-end=\"2540\"\u003e\u003cstrong data-start=\"2454\" data-end=\"2491\"\u003e3. Does it include a main switch?\u003c\/strong\u003e\u003cbr data-start=\"2491\" data-end=\"2494\"\u003eYes, it comes with a 100A main switch incomer.\u003c\/p\u003e\n\u003cp data-start=\"2542\" data-end=\"2660\"\u003e\u003cstrong data-start=\"2542\" data-end=\"2571\"\u003e4. Is it easy to install?\u003c\/strong\u003e\u003cbr data-start=\"2571\" data-end=\"2574\"\u003eYes, its compact design and simple layout make installation quick and straightforward.\u003c\/p\u003e\n\u003cp data-start=\"2662\" data-end=\"2801\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2662\" data-end=\"2714\"\u003e5. Is it suitable for modern electrical systems?\u003c\/strong\u003e\u003cbr data-start=\"2714\" data-end=\"2717\"\u003eYes, it is designed to meet the needs of modern residential electrical distribution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272800575870,"sku":null,"price":25.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E0604-side.png?v=1776461575"},{"product_id":"excel-e1008-main-switch-incomer-consumer-unit-10-module-8-way","title":"Excel E1008 Main Switch Incomer Consumer Unit 10 Module 8 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-74\" data-testid=\"conversation-turn-34\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"342ba261-7ef2-4227-87c9-973bf5537f4b\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"342\" data-end=\"355\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"356\" data-end=\"669\"\u003eThe Excel E1008 Main Switch Incomer Consumer Unit is a practical and efficient solution for electrical distribution in residential and light commercial settings. With a 10-module enclosure and 8 usable ways, it offers ample capacity for managing multiple circuits while maintaining a compact and organized design.\u003c\/p\u003e\n\u003cp data-start=\"671\" data-end=\"979\"\u003eEquipped with a 100A main switch incomer, this consumer unit ensures reliable power control and safe isolation when needed. Its durable construction and straightforward layout make it an ideal choice for electricians seeking an easy-to-install and dependable distribution board for modern electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"981\" data-end=\"984\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"986\" data-end=\"1003\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1004\" data-end=\"1398\"\u003e\n\u003cli data-section-id=\"1hewy8c\" data-start=\"1004\" data-end=\"1050\"\u003e10-module consumer unit with 8 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"18lhnlc\" data-start=\"1051\" data-end=\"1093\"\u003eSupplied with 100A main switch incomer\u003c\/li\u003e\n\u003cli data-section-id=\"1bdd9s6\" data-start=\"1094\" data-end=\"1132\"\u003eCompact and space-efficient design\u003c\/li\u003e\n\u003cli data-section-id=\"1s3haq8\" data-start=\"1133\" data-end=\"1195\"\u003eSuitable for residential and light commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1196\" data-end=\"1233\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"dt94t6\" data-start=\"1234\" data-end=\"1269\"\u003eDurable and robust construction\u003c\/li\u003e\n\u003cli data-section-id=\"1dk7x0c\" data-start=\"1270\" data-end=\"1309\"\u003eClean and organized internal layout\u003c\/li\u003e\n\u003cli data-section-id=\"1yjenu4\" data-start=\"1310\" data-end=\"1350\"\u003eReliable power distribution solution\u003c\/li\u003e\n\u003cli data-section-id=\"1kutzkt\" data-start=\"1351\" data-end=\"1398\"\u003eDesigned for modern electrical requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1400\" data-end=\"1403\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1405\" data-end=\"1434\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1435\" data-end=\"1633\"\u003e\n\u003cli data-section-id=\"w1ek5v\" data-start=\"1435\" data-end=\"1449\"\u003eSKU: E1008\u003c\/li\u003e\n\u003cli data-section-id=\"1osty34\" data-start=\"1450\" data-end=\"1475\"\u003eNumber of Modules: 10\u003c\/li\u003e\n\u003cli data-section-id=\"1l5ze2i\" data-start=\"1476\" data-end=\"1494\"\u003eUsable Ways: 8\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1495\" data-end=\"1523\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"d9xjwa\" data-start=\"1524\" data-end=\"1567\"\u003eType: Main Switch Incomer Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1568\" data-end=\"1633\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1635\" data-end=\"1638\"\u003e\n\u003ch2 data-section-id=\"uo9xmk\" data-start=\"1640\" data-end=\"1683\"\u003eWhy Choose a Excel E1008 Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1684\" data-end=\"1940\"\u003eThe Excel E1008 consumer unit is an excellent choice for installations that require more circuit capacity without increasing complexity. Its 8 usable ways provide flexibility for various electrical setups, making it suitable for growing electrical demands.\u003c\/p\u003e\n\u003cp data-start=\"1942\" data-end=\"2160\"\u003eWith its reliable 100A main switch and durable build, it ensures safe and efficient power distribution. Its installer-friendly design simplifies setup, making it a trusted option for professionals and homeowners alike.\u003c\/p\u003e\n\u003chr data-start=\"2162\" data-end=\"2165\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2167\" data-end=\"2176\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2178\" data-end=\"2340\"\u003e\u003cstrong data-start=\"2178\" data-end=\"2247\"\u003e1. What type of installations is this consumer unit suitable for?\u003c\/strong\u003e\u003cbr data-start=\"2247\" data-end=\"2250\"\u003eIt is ideal for residential and light commercial applications requiring multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"2342\" data-end=\"2417\"\u003e\u003cstrong data-start=\"2342\" data-end=\"2382\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2382\" data-end=\"2385\"\u003eIt supports up to 8 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2419\" data-end=\"2505\"\u003e\u003cstrong data-start=\"2419\" data-end=\"2456\"\u003e3. Does it include a main switch?\u003c\/strong\u003e\u003cbr data-start=\"2456\" data-end=\"2459\"\u003eYes, it comes with a 100A main switch incomer.\u003c\/p\u003e\n\u003cp data-start=\"2507\" data-end=\"2614\"\u003e\u003cstrong data-start=\"2507\" data-end=\"2536\"\u003e4. Is it easy to install?\u003c\/strong\u003e\u003cbr data-start=\"2536\" data-end=\"2539\"\u003eYes, its compact design and clear layout make installation straightforward.\u003c\/p\u003e\n\u003cp data-start=\"2616\" data-end=\"2737\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2616\" data-end=\"2668\"\u003e5. Is it suitable for modern electrical systems?\u003c\/strong\u003e\u003cbr data-start=\"2668\" data-end=\"2671\"\u003eYes, it is designed to meet current electrical distribution needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272845468030,"sku":null,"price":31.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E0604-side_1.png?v=1776462231"},{"product_id":"excel-e1412-main-switch-incomer-consumer-unit-14-module-12-way","title":"Excel E1412 Main Switch Incomer Consumer Unit 14 Module 12 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-75\" data-testid=\"conversation-turn-36\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"a9f5a7da-5eac-4fac-96d9-ef913db9769e\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"360\" data-end=\"373\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"374\" data-end=\"718\"\u003eThe Excel E1412 Main Switch Incomer Consumer Unit is a high-capacity and reliable solution designed for efficient electrical distribution in residential and light commercial environments. With a 14-module enclosure and 12 usable ways, it offers excellent flexibility for managing multiple circuits while maintaining a neat and organized layout.\u003c\/p\u003e\n\u003cp data-start=\"720\" data-end=\"1010\"\u003eEquipped with a 100A main switch incomer, this consumer unit ensures safe isolation and dependable power control. Its durable construction and user-friendly design make it ideal for electricians and installers who require a practical, easy-to-install solution for modern electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"1012\" data-end=\"1015\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1017\" data-end=\"1034\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1035\" data-end=\"1436\"\u003e\n\u003cli data-section-id=\"1g86cwj\" data-start=\"1035\" data-end=\"1082\"\u003e14-module consumer unit with 12 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"18lhnlc\" data-start=\"1083\" data-end=\"1125\"\u003eSupplied with 100A main switch incomer\u003c\/li\u003e\n\u003cli data-section-id=\"1hjjyli\" data-start=\"1126\" data-end=\"1172\"\u003eHigh-capacity design for multiple circuits\u003c\/li\u003e\n\u003cli data-section-id=\"t5ogni\" data-start=\"1173\" data-end=\"1214\"\u003eCompact and space-efficient enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1gkt1yy\" data-start=\"1215\" data-end=\"1268\"\u003eSuitable for residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1269\" data-end=\"1306\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1307\" data-end=\"1348\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003cli data-section-id=\"1dk7x0c\" data-start=\"1349\" data-end=\"1388\"\u003eClean and organized internal layout\u003c\/li\u003e\n\u003cli data-section-id=\"1kutzkt\" data-start=\"1389\" data-end=\"1436\"\u003eDesigned for modern electrical requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1438\" data-end=\"1441\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1443\" data-end=\"1472\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1473\" data-end=\"1672\"\u003e\n\u003cli data-section-id=\"w493jw\" data-start=\"1473\" data-end=\"1487\"\u003eSKU: E1412\u003c\/li\u003e\n\u003cli data-section-id=\"1osu1g4\" data-start=\"1488\" data-end=\"1513\"\u003eNumber of Modules: 14\u003c\/li\u003e\n\u003cli data-section-id=\"13oe5i9\" data-start=\"1514\" data-end=\"1533\"\u003eUsable Ways: 12\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1534\" data-end=\"1562\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"d9xjwa\" data-start=\"1563\" data-end=\"1606\"\u003eType: Main Switch Incomer Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1607\" data-end=\"1672\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1674\" data-end=\"1677\"\u003e\n\u003ch2 data-section-id=\"1e283wz\" data-start=\"1679\" data-end=\"1722\"\u003eWhy Choose a Excel E1412 Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1723\" data-end=\"1972\"\u003eThe Excel E1412 consumer unit is ideal for installations requiring higher circuit capacity and reliable performance. Its 12 usable ways allow for flexible circuit distribution, making it suitable for growing electrical needs in homes and businesses.\u003c\/p\u003e\n\u003cp data-start=\"1974\" data-end=\"2198\"\u003eWith a robust 100A main switch and durable construction, it ensures safe and efficient operation. Its straightforward design simplifies installation, making it a dependable choice for professionals and property owners alike.\u003c\/p\u003e\n\u003chr data-start=\"2200\" data-end=\"2203\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2205\" data-end=\"2214\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2216\" data-end=\"2378\"\u003e\u003cstrong data-start=\"2216\" data-end=\"2285\"\u003e1. What type of installations is this consumer unit suitable for?\u003c\/strong\u003e\u003cbr data-start=\"2285\" data-end=\"2288\"\u003eIt is ideal for residential and light commercial applications requiring multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"2380\" data-end=\"2456\"\u003e\u003cstrong data-start=\"2380\" data-end=\"2420\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2420\" data-end=\"2423\"\u003eIt supports up to 12 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2458\" data-end=\"2544\"\u003e\u003cstrong data-start=\"2458\" data-end=\"2495\"\u003e3. Does it include a main switch?\u003c\/strong\u003e\u003cbr data-start=\"2495\" data-end=\"2498\"\u003eYes, it comes with a 100A main switch incomer.\u003c\/p\u003e\n\u003cp data-start=\"2546\" data-end=\"2644\"\u003e\u003cstrong data-start=\"2546\" data-end=\"2575\"\u003e4. Is it easy to install?\u003c\/strong\u003e\u003cbr data-start=\"2575\" data-end=\"2578\"\u003eYes, its design allows for quick and straightforward installation.\u003c\/p\u003e\n\u003cp data-start=\"2646\" data-end=\"2781\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2646\" data-end=\"2698\"\u003e5. Is it suitable for modern electrical systems?\u003c\/strong\u003e\u003cbr data-start=\"2698\" data-end=\"2701\"\u003eYes, it is designed to meet current electrical distribution standards and needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272883872126,"sku":null,"price":37.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E1412-side.png?v=1776462554"},{"product_id":"excel-e1816-main-switch-incomer-consumer-unit-18-module-16-way","title":"Excel E1816 Main Switch Incomer Consumer Unit 18 Module 16 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-76\" data-testid=\"conversation-turn-38\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"18c20cb2-7bbe-4f44-a5a7-a9d33f152d2c\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"351\" data-end=\"364\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"365\" data-end=\"718\"\u003eThe Excel E1816 Main Switch Incomer Consumer Unit is a high-capacity and efficient electrical distribution solution designed for modern residential and light commercial installations. With an 18-module enclosure and 16 usable ways, it provides excellent flexibility for managing multiple circuits while maintaining a clean and organized internal layout.\u003c\/p\u003e\n\u003cp data-start=\"720\" data-end=\"1007\"\u003eEquipped with a 100A main switch incomer, this consumer unit ensures reliable power control and safe isolation. Its robust construction and installer-friendly design make it an ideal choice for electricians seeking a dependable and easy-to-install solution for larger electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"1009\" data-end=\"1012\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1014\" data-end=\"1031\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1032\" data-end=\"1461\"\u003e\n\u003cli data-section-id=\"1kl74uz\" data-start=\"1032\" data-end=\"1079\"\u003e18-module consumer unit with 16 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"18lhnlc\" data-start=\"1080\" data-end=\"1122\"\u003eSupplied with 100A main switch incomer\u003c\/li\u003e\n\u003cli data-section-id=\"lkd3jo\" data-start=\"1123\" data-end=\"1182\"\u003eHigh-capacity design for extensive circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1xuceti\" data-start=\"1183\" data-end=\"1223\"\u003eCompact and well-organized enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1s3haq8\" data-start=\"1224\" data-end=\"1286\"\u003eSuitable for residential and light commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1287\" data-end=\"1324\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1325\" data-end=\"1366\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003cli data-section-id=\"1cemva6\" data-start=\"1367\" data-end=\"1413\"\u003eClean internal layout for efficient wiring\u003c\/li\u003e\n\u003cli data-section-id=\"1kutzkt\" data-start=\"1414\" data-end=\"1461\"\u003eDesigned for modern electrical requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1463\" data-end=\"1466\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1468\" data-end=\"1497\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1498\" data-end=\"1697\"\u003e\n\u003cli data-section-id=\"vvs65w\" data-start=\"1498\" data-end=\"1512\"\u003eSKU: E1816\u003c\/li\u003e\n\u003cli data-section-id=\"1osu4t4\" data-start=\"1513\" data-end=\"1538\"\u003eNumber of Modules: 18\u003c\/li\u003e\n\u003cli data-section-id=\"13oe8v9\" data-start=\"1539\" data-end=\"1558\"\u003eUsable Ways: 16\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1559\" data-end=\"1587\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"d9xjwa\" data-start=\"1588\" data-end=\"1631\"\u003eType: Main Switch Incomer Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1632\" data-end=\"1697\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1699\" data-end=\"1702\"\u003e\n\u003ch2 data-section-id=\"19amnyz\" data-start=\"1704\" data-end=\"1747\"\u003eWhy Choose a Excel E1816 Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1748\" data-end=\"2015\"\u003eThe Excel E1816 consumer unit is an excellent choice for installations that require a larger number of circuits without compromising on reliability. Its 16 usable ways provide flexibility for expanding electrical systems and managing multiple connections efficiently.\u003c\/p\u003e\n\u003cp data-start=\"2017\" data-end=\"2256\"\u003eWith a strong 100A main switch and durable construction, it ensures safe and consistent performance. Its user-friendly design makes installation simple, offering a practical and dependable solution for modern electrical distribution needs.\u003c\/p\u003e\n\u003chr data-start=\"2258\" data-end=\"2261\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2263\" data-end=\"2272\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2274\" data-end=\"2436\"\u003e\u003cstrong data-start=\"2274\" data-end=\"2342\"\u003e1. What type of installation is this consumer unit suitable for?\u003c\/strong\u003e\u003cbr data-start=\"2342\" data-end=\"2345\"\u003eIt is ideal for larger residential and light commercial setups requiring multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"2438\" data-end=\"2514\"\u003e\u003cstrong data-start=\"2438\" data-end=\"2478\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2478\" data-end=\"2481\"\u003eIt supports up to 16 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2516\" data-end=\"2602\"\u003e\u003cstrong data-start=\"2516\" data-end=\"2553\"\u003e3. Does it include a main switch?\u003c\/strong\u003e\u003cbr data-start=\"2553\" data-end=\"2556\"\u003eYes, it comes with a 100A main switch incomer.\u003c\/p\u003e\n\u003cp data-start=\"2604\" data-end=\"2712\"\u003e\u003cstrong data-start=\"2604\" data-end=\"2633\"\u003e4. Is it easy to install?\u003c\/strong\u003e\u003cbr data-start=\"2633\" data-end=\"2636\"\u003eYes, its organized layout allows for quick and straightforward installation.\u003c\/p\u003e\n\u003cp data-start=\"2714\" data-end=\"2849\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2714\" data-end=\"2766\"\u003e5. Is it suitable for modern electrical systems?\u003c\/strong\u003e\u003cbr data-start=\"2766\" data-end=\"2769\"\u003eYes, it is designed to meet current electrical distribution needs and standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272925913470,"sku":null,"price":42.43,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-35.png?v=1776462820"},{"product_id":"excel-e2422-main-switch-incomer-consumer-unit-24-module-22-way","title":"Excel E2422 Main Switch Incomer Consumer Unit 24 Module 22 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-77\" data-testid=\"conversation-turn-40\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"38c5d67f-2fe8-42a5-80fe-dffa20d3a847\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"351\" data-end=\"364\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"365\" data-end=\"691\"\u003eThe Excel E2422 Main Switch Incomer Consumer Unit is a high-capacity electrical distribution solution designed for large residential and light commercial installations. With a 24-module enclosure and 22 usable ways, it offers extensive flexibility for managing multiple circuits while maintaining a clean and organized layout.\u003c\/p\u003e\n\u003cp data-start=\"693\" data-end=\"991\"\u003eEquipped with a 100A main switch incomer, this consumer unit ensures reliable power control and safe isolation. Its robust construction and practical design make it an ideal choice for electricians and installers who require a dependable and easy-to-install solution for complex electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"993\" data-end=\"996\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"998\" data-end=\"1015\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1016\" data-end=\"1452\"\u003e\n\u003cli data-section-id=\"1blxto3\" data-start=\"1016\" data-end=\"1063\"\u003e24-module consumer unit with 22 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"18lhnlc\" data-start=\"1064\" data-end=\"1106\"\u003eSupplied with 100A main switch incomer\u003c\/li\u003e\n\u003cli data-section-id=\"lkd3jo\" data-start=\"1107\" data-end=\"1166\"\u003eHigh-capacity design for extensive circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"2xifqj\" data-start=\"1167\" data-end=\"1236\"\u003eSuitable for large residential and light commercial installations\u003c\/li\u003e\n\u003cli data-section-id=\"120cbow\" data-start=\"1237\" data-end=\"1278\"\u003eCompact and well-structured enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1279\" data-end=\"1316\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1317\" data-end=\"1358\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003cli data-section-id=\"q4p49o\" data-start=\"1359\" data-end=\"1409\"\u003eOrganized internal layout for efficient wiring\u003c\/li\u003e\n\u003cli data-section-id=\"evza9z\" data-start=\"1410\" data-end=\"1452\"\u003eDesigned for modern electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1454\" data-end=\"1457\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1459\" data-end=\"1488\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1489\" data-end=\"1688\"\u003e\n\u003cli data-section-id=\"vflrjw\" data-start=\"1489\" data-end=\"1503\"\u003eSKU: E2422\u003c\/li\u003e\n\u003cli data-section-id=\"1osxugn\" data-start=\"1504\" data-end=\"1529\"\u003eNumber of Modules: 24\u003c\/li\u003e\n\u003cli data-section-id=\"13oafuq\" data-start=\"1530\" data-end=\"1549\"\u003eUsable Ways: 22\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1550\" data-end=\"1578\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"d9xjwa\" data-start=\"1579\" data-end=\"1622\"\u003eType: Main Switch Incomer Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1623\" data-end=\"1688\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1690\" data-end=\"1693\"\u003e\n\u003ch2 data-section-id=\"10yr55f\" data-start=\"1695\" data-end=\"1738\"\u003eWhy Choose a Excel E2422 Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1739\" data-end=\"1975\"\u003eThe Excel E2422 consumer unit is ideal for installations that demand maximum circuit capacity and reliable performance. Its 22 usable ways provide exceptional flexibility, making it suitable for complex and expanding electrical systems.\u003c\/p\u003e\n\u003cp data-start=\"1977\" data-end=\"2225\"\u003eWith a durable build and a dependable 100A main switch, it ensures safe and efficient operation. Its user-friendly design simplifies installation, making it a trusted solution for professionals handling large-scale electrical distribution projects.\u003c\/p\u003e\n\u003chr data-start=\"2227\" data-end=\"2230\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2232\" data-end=\"2241\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2243\" data-end=\"2416\"\u003e\u003cstrong data-start=\"2243\" data-end=\"2312\"\u003e1. What type of installations is this consumer unit suitable for?\u003c\/strong\u003e\u003cbr data-start=\"2312\" data-end=\"2315\"\u003eIt is ideal for large residential properties and light commercial setups requiring multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"2418\" data-end=\"2494\"\u003e\u003cstrong data-start=\"2418\" data-end=\"2458\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2458\" data-end=\"2461\"\u003eIt supports up to 22 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2496\" data-end=\"2582\"\u003e\u003cstrong data-start=\"2496\" data-end=\"2533\"\u003e3. Does it include a main switch?\u003c\/strong\u003e\u003cbr data-start=\"2533\" data-end=\"2536\"\u003eYes, it comes with a 100A main switch incomer.\u003c\/p\u003e\n\u003cp data-start=\"2584\" data-end=\"2682\"\u003e\u003cstrong data-start=\"2584\" data-end=\"2613\"\u003e4. Is it easy to install?\u003c\/strong\u003e\u003cbr data-start=\"2613\" data-end=\"2616\"\u003eYes, its organized design allows for straightforward installation.\u003c\/p\u003e\n\u003cp data-start=\"2684\" data-end=\"2812\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2684\" data-end=\"2736\"\u003e5. Is it suitable for modern electrical systems?\u003c\/strong\u003e\u003cbr data-start=\"2736\" data-end=\"2739\"\u003eYes, it is designed to meet current electrical distribution requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272955961726,"sku":null,"price":51.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E2422-side.png?v=1776463143"},{"product_id":"excel-e2825-28-module-dual-stack-consumer-unit-25-way","title":"Excel E2825 28 Module Dual Stack Consumer Unit 25 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-78\" data-testid=\"conversation-turn-42\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"043c5fbf-8458-4de3-af16-a212cecb816b\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"338\" data-end=\"351\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"352\" data-end=\"674\"\u003eThe Excel E2825 28 Module Dual Stack Consumer Unit is a high-capacity electrical distribution solution designed for large residential and light commercial installations. With 25 usable ways, it provides extensive flexibility for managing multiple circuits while maintaining a compact and space-efficient dual stack design.\u003c\/p\u003e\n\u003cp data-start=\"676\" data-end=\"973\"\u003eEquipped with a 100A main switch incomer, this consumer unit ensures reliable power control and safe isolation. Its robust construction and organized internal layout make it ideal for electricians and installers who require a dependable and easy-to-install solution for complex electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"975\" data-end=\"978\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"980\" data-end=\"997\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"998\" data-end=\"1433\"\u003e\n\u003cli data-section-id=\"1qkr231\" data-start=\"998\" data-end=\"1043\"\u003e28-module dual stack consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"1mnmutn\" data-start=\"1044\" data-end=\"1091\"\u003e25 usable ways for maximum circuit capacity\u003c\/li\u003e\n\u003cli data-section-id=\"18lhnlc\" data-start=\"1092\" data-end=\"1134\"\u003eSupplied with 100A main switch incomer\u003c\/li\u003e\n\u003cli data-section-id=\"1i0shev\" data-start=\"1135\" data-end=\"1176\"\u003eSpace-saving dual stack configuration\u003c\/li\u003e\n\u003cli data-section-id=\"2xifqj\" data-start=\"1177\" data-end=\"1246\"\u003eSuitable for large residential and light commercial installations\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1247\" data-end=\"1284\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1285\" data-end=\"1326\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003cli data-section-id=\"q4p49o\" data-start=\"1327\" data-end=\"1377\"\u003eOrganized internal layout for efficient wiring\u003c\/li\u003e\n\u003cli data-section-id=\"1xgpaql\" data-start=\"1378\" data-end=\"1433\"\u003eDesigned for modern electrical distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1435\" data-end=\"1438\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1440\" data-end=\"1469\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1470\" data-end=\"1680\"\u003e\n\u003cli data-section-id=\"v74ybb\" data-start=\"1470\" data-end=\"1484\"\u003eSKU: E2825\u003c\/li\u003e\n\u003cli data-section-id=\"1osxxtn\" data-start=\"1485\" data-end=\"1510\"\u003eNumber of Modules: 28\u003c\/li\u003e\n\u003cli data-section-id=\"13oagqt\" data-start=\"1511\" data-end=\"1530\"\u003eUsable Ways: 25\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1531\" data-end=\"1559\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"17droco\" data-start=\"1560\" data-end=\"1614\"\u003eType: Dual Stack Main Switch Incomer Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1615\" data-end=\"1680\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1682\" data-end=\"1685\"\u003e\n\u003ch2 data-section-id=\"wrrheg\" data-start=\"1687\" data-end=\"1730\"\u003eWhy Choose a Excel E2825 Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1731\" data-end=\"2010\"\u003eThe Excel E2825 consumer unit is the ideal choice for installations requiring maximum circuit capacity within a compact footprint. Its dual stack design allows efficient use of space while accommodating a large number of circuits, making it perfect for complex electrical setups.\u003c\/p\u003e\n\u003cp data-start=\"2012\" data-end=\"2265\"\u003eWith a reliable 100A main switch and durable build quality, it ensures safe and consistent performance. Its installer-friendly design simplifies setup, making it a trusted solution for professionals handling high-demand electrical distribution projects.\u003c\/p\u003e\n\u003chr data-start=\"2267\" data-end=\"2270\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2272\" data-end=\"2281\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2283\" data-end=\"2431\"\u003e\u003cstrong data-start=\"2283\" data-end=\"2325\"\u003e1. What is a dual stack consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"2325\" data-end=\"2328\"\u003eIt is a design that allows circuits to be arranged in two rows, maximizing capacity while saving space.\u003c\/p\u003e\n\u003cp data-start=\"2433\" data-end=\"2509\"\u003e\u003cstrong data-start=\"2433\" data-end=\"2473\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2473\" data-end=\"2476\"\u003eIt supports up to 25 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2511\" data-end=\"2597\"\u003e\u003cstrong data-start=\"2511\" data-end=\"2548\"\u003e3. Does it include a main switch?\u003c\/strong\u003e\u003cbr data-start=\"2548\" data-end=\"2551\"\u003eYes, it comes with a 100A main switch incomer.\u003c\/p\u003e\n\u003cp data-start=\"2599\" data-end=\"2721\"\u003e\u003cstrong data-start=\"2599\" data-end=\"2645\"\u003e4. Is it suitable for large installations?\u003c\/strong\u003e\u003cbr data-start=\"2645\" data-end=\"2648\"\u003eYes, it is ideal for large residential and light commercial applications.\u003c\/p\u003e\n\u003cp data-start=\"2723\" data-end=\"2839\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2723\" data-end=\"2762\"\u003e5. Is installation straightforward?\u003c\/strong\u003e\u003cbr data-start=\"2762\" data-end=\"2765\"\u003eYes, its organized layout and design make installation efficient and easy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57272987517310,"sku":null,"price":85.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-54_aa4491b0-5a97-4d41-b56e-a9f5479cebaf.png?v=1776463391"},{"product_id":"excel-e3633-36-module-dual-stack-consumer-unit-33-way","title":"Excel E3633 36 Module Dual Stack Consumer Unit 33 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-79\" data-testid=\"conversation-turn-44\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"97b2a97c-b6d5-43aa-bbd4-5bea7a6a96eb\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"338\" data-end=\"351\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"352\" data-end=\"688\"\u003eThe Excel E3633 36 Module Dual Stack Consumer Unit is a premium high-capacity solution designed for large-scale residential and light commercial electrical installations. With an impressive 33 usable ways, it offers maximum flexibility for managing extensive circuit layouts while maintaining a structured and organized internal design.\u003c\/p\u003e\n\u003cp data-start=\"690\" data-end=\"1024\"\u003eBuilt with a space-efficient dual stack configuration, this consumer unit allows for increased circuit capacity without significantly increasing installation space. Equipped with a 100A main switch incomer, it ensures reliable power control and safe isolation, making it an ideal choice for complex and high-demand electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"1026\" data-end=\"1029\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1031\" data-end=\"1048\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1049\" data-end=\"1469\"\u003e\n\u003cli data-section-id=\"13b9ssi\" data-start=\"1049\" data-end=\"1094\"\u003e36-module dual stack consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"11eum0y\" data-start=\"1095\" data-end=\"1146\"\u003e33 usable ways for maximum circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"18lhnlc\" data-start=\"1147\" data-end=\"1189\"\u003eSupplied with 100A main switch incomer\u003c\/li\u003e\n\u003cli data-section-id=\"1i0shev\" data-start=\"1190\" data-end=\"1231\"\u003eSpace-saving dual stack configuration\u003c\/li\u003e\n\u003cli data-section-id=\"2xifqj\" data-start=\"1232\" data-end=\"1301\"\u003eSuitable for large residential and light commercial installations\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1302\" data-end=\"1339\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"dt94t6\" data-start=\"1340\" data-end=\"1375\"\u003eDurable and robust construction\u003c\/li\u003e\n\u003cli data-section-id=\"q4p49o\" data-start=\"1376\" data-end=\"1426\"\u003eOrganized internal layout for efficient wiring\u003c\/li\u003e\n\u003cli data-section-id=\"evza9z\" data-start=\"1427\" data-end=\"1469\"\u003eDesigned for modern electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1471\" data-end=\"1474\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1476\" data-end=\"1505\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1506\" data-end=\"1716\"\u003e\n\u003cli data-section-id=\"uv0xxb\" data-start=\"1506\" data-end=\"1520\"\u003eSKU: E3633\u003c\/li\u003e\n\u003cli data-section-id=\"1osvj84\" data-start=\"1521\" data-end=\"1546\"\u003eNumber of Modules: 36\u003c\/li\u003e\n\u003cli data-section-id=\"13ocmxu\" data-start=\"1547\" data-end=\"1566\"\u003eUsable Ways: 33\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1567\" data-end=\"1595\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"17droco\" data-start=\"1596\" data-end=\"1650\"\u003eType: Dual Stack Main Switch Incomer Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1651\" data-end=\"1716\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1718\" data-end=\"1721\"\u003e\n\u003ch2 data-section-id=\"19dqzbk\" data-start=\"1723\" data-end=\"1766\"\u003eWhy Choose a Excel E3633 Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1767\" data-end=\"2034\"\u003eThe Excel E3633 consumer unit is the perfect choice for installations requiring the highest level of circuit capacity and flexibility. Its dual stack design allows electricians to efficiently manage a large number of circuits within a compact and organized enclosure.\u003c\/p\u003e\n\u003cp data-start=\"2036\" data-end=\"2289\"\u003eWith a reliable 100A main switch and durable construction, it ensures safe and consistent performance. Its installer-friendly design reduces setup time and enhances efficiency, making it a trusted solution for demanding electrical distribution projects.\u003c\/p\u003e\n\u003chr data-start=\"2291\" data-end=\"2294\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2296\" data-end=\"2305\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2307\" data-end=\"2465\"\u003e\u003cstrong data-start=\"2307\" data-end=\"2377\"\u003e1. What makes this consumer unit suitable for large installations?\u003c\/strong\u003e\u003cbr data-start=\"2377\" data-end=\"2380\"\u003eIts 33 usable ways provide extensive circuit capacity for complex electrical systems.\u003c\/p\u003e\n\u003cp data-start=\"2467\" data-end=\"2591\"\u003e\u003cstrong data-start=\"2467\" data-end=\"2502\"\u003e2. What is a dual stack design?\u003c\/strong\u003e\u003cbr data-start=\"2502\" data-end=\"2505\"\u003eIt allows circuits to be arranged in two rows, maximizing capacity while saving space.\u003c\/p\u003e\n\u003cp data-start=\"2593\" data-end=\"2679\"\u003e\u003cstrong data-start=\"2593\" data-end=\"2630\"\u003e3. Does it include a main switch?\u003c\/strong\u003e\u003cbr data-start=\"2630\" data-end=\"2633\"\u003eYes, it comes with a 100A main switch incomer.\u003c\/p\u003e\n\u003cp data-start=\"2681\" data-end=\"2798\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2722\"\u003e4. Is it suitable for commercial use?\u003c\/strong\u003e\u003cbr data-start=\"2722\" data-end=\"2725\"\u003eYes, it is ideal for large residential and light commercial applications.\u003c\/p\u003e\n\u003cp data-start=\"2800\" data-end=\"2917\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2800\" data-end=\"2828\"\u003e5. Is installation easy?\u003c\/strong\u003e\u003cbr data-start=\"2828\" data-end=\"2831\"\u003eYes, its structured layout and design make installation efficient and straightforward.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57273030607230,"sku":null,"price":96.51,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-53.png?v=1776463733"},{"product_id":"excel-e0604r-rcd-incomer-consumer-unit-6-module-4-way","title":"Excel E0604R RCD Incomer Consumer Unit 6 Module 4 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-81\" data-testid=\"conversation-turn-46\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"8a761fd8-95a7-4d4e-b6e8-adc97b6a7d6d\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"333\" data-end=\"346\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"347\" data-end=\"729\"\u003eThe Excel E0604R RCD Incomer Consumer Unit is a compact and reliable electrical distribution solution designed to provide enhanced circuit protection. With a 6-module enclosure and 4 usable ways, it is ideal for smaller installations requiring efficient power management and safety. Its design supports applications across residential, commercial, and light industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"731\" data-end=\"1066\"\u003eEquipped with a 63A RCD incomer, this consumer unit offers protection against earth leakage and electrical faults, ensuring improved safety for both users and connected equipment. Suitable for circuits up to 690V, it is a versatile and dependable option for transformers, control systems, metering, and low voltage distribution setups.\u003c\/p\u003e\n\u003chr data-start=\"1068\" data-end=\"1071\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1073\" data-end=\"1090\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1091\" data-end=\"1505\"\u003e\n\u003cli data-section-id=\"6tydg\" data-start=\"1091\" data-end=\"1132\"\u003e6-module compact consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"1x8iny6\" data-start=\"1133\" data-end=\"1175\"\u003e4 usable ways for circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"xrmwy0\" data-start=\"1176\" data-end=\"1209\"\u003eSupplied with 63A RCD incomer\u003c\/li\u003e\n\u003cli data-section-id=\"1ryp7n8\" data-start=\"1210\" data-end=\"1266\"\u003eProvides protection against earth leakage and faults\u003c\/li\u003e\n\u003cli data-section-id=\"16wlcj9\" data-start=\"1267\" data-end=\"1303\"\u003eSuitable for circuits up to 690V\u003c\/li\u003e\n\u003cli data-section-id=\"1y9ge7k\" data-start=\"1304\" data-end=\"1375\"\u003eIdeal for transformers, control circuits, and metering applications\u003c\/li\u003e\n\u003cli data-section-id=\"1jbmzk7\" data-start=\"1376\" data-end=\"1416\"\u003eSpace-saving and practical enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1417\" data-end=\"1454\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"cqmrlq\" data-start=\"1455\" data-end=\"1505\"\u003eDurable construction for long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1507\" data-end=\"1510\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1512\" data-end=\"1541\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1542\" data-end=\"1775\"\u003e\n\u003cli data-section-id=\"d82lbe\" data-start=\"1542\" data-end=\"1557\"\u003eSKU: E0604R\u003c\/li\u003e\n\u003cli data-section-id=\"l7q7l3\" data-start=\"1558\" data-end=\"1582\"\u003eNumber of Modules: 6\u003c\/li\u003e\n\u003cli data-section-id=\"1l5zapi\" data-start=\"1583\" data-end=\"1601\"\u003eUsable Ways: 4\u003c\/li\u003e\n\u003cli data-section-id=\"wojdqi\" data-start=\"1602\" data-end=\"1627\"\u003eIncomer Type: 63A RCD\u003c\/li\u003e\n\u003cli data-section-id=\"16s2ql\" data-start=\"1628\" data-end=\"1663\"\u003eVoltage Application: Up to 690V\u003c\/li\u003e\n\u003cli data-section-id=\"1k739iu\" data-start=\"1664\" data-end=\"1699\"\u003eType: RCD Incomer Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"kt47le\" data-start=\"1700\" data-end=\"1775\"\u003eApplication: Residential, Commercial, and Industrial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1777\" data-end=\"1780\"\u003e\n\u003ch2 data-section-id=\"1lprpet\" data-start=\"1782\" data-end=\"1826\"\u003eWhy Choose a Excel E0604R Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1827\" data-end=\"2074\"\u003eThe Excel E0604R consumer unit is an excellent choice for installations requiring enhanced safety through RCD protection. Its ability to detect and prevent earth leakage faults makes it a reliable solution for protecting both people and equipment.\u003c\/p\u003e\n\u003cp data-start=\"2076\" data-end=\"2325\"\u003eWith its compact design and versatile application range, it is suitable for various electrical setups. Its easy installation and durable build make it a practical and dependable option for professionals seeking efficient and safe power distribution.\u003c\/p\u003e\n\u003chr data-start=\"2327\" data-end=\"2330\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2332\" data-end=\"2341\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2343\" data-end=\"2480\"\u003e\u003cstrong data-start=\"2343\" data-end=\"2393\"\u003e1. What is the main benefit of an RCD incomer?\u003c\/strong\u003e\u003cbr data-start=\"2393\" data-end=\"2396\"\u003eIt provides protection against earth leakage and reduces the risk of electric shock.\u003c\/p\u003e\n\u003cp data-start=\"2482\" data-end=\"2564\"\u003e\u003cstrong data-start=\"2482\" data-end=\"2529\"\u003e2. How many circuits can this unit support?\u003c\/strong\u003e\u003cbr data-start=\"2529\" data-end=\"2532\"\u003eIt supports up to 4 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2566\" data-end=\"2638\"\u003e\u003cstrong data-start=\"2566\" data-end=\"2603\"\u003e3. What is the rating of the RCD?\u003c\/strong\u003e\u003cbr data-start=\"2603\" data-end=\"2606\"\u003eIt comes with a 63A RCD incomer.\u003c\/p\u003e\n\u003cp data-start=\"2640\" data-end=\"2777\"\u003e\u003cstrong data-start=\"2640\" data-end=\"2684\"\u003e4. What applications is it suitable for?\u003c\/strong\u003e\u003cbr data-start=\"2684\" data-end=\"2687\"\u003eIt is suitable for transformers, control circuits, metering, and low voltage distribution.\u003c\/p\u003e\n\u003cp data-start=\"2779\" data-end=\"2874\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2779\" data-end=\"2827\"\u003e5. Is it suitable for high voltage circuits?\u003c\/strong\u003e\u003cbr data-start=\"2827\" data-end=\"2830\"\u003eYes, it can be used for circuits up to 690V.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57273330860414,"sku":null,"price":34.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E0604R-side.png?v=1776465091"},{"product_id":"excel-e1008r-rcd-incomer-consumer-unit-10-module-8-way","title":"Excel E1008R RCD Incomer Consumer Unit 10 Module 8 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-82\" data-testid=\"conversation-turn-48\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"6a9ffa76-b6ab-4fe0-8607-2afc6b859855\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"330\" data-end=\"343\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"344\" data-end=\"660\"\u003eThe Excel E1008R RCD Incomer Consumer Unit is a reliable and versatile electrical distribution solution designed for enhanced safety and performance. With a 10-module enclosure and 8 usable ways, it provides ample capacity for managing multiple circuits in residential, commercial, and light industrial applications.\u003c\/p\u003e\n\u003cp data-start=\"662\" data-end=\"989\"\u003eEquipped with a 63A RCD incomer, this consumer unit offers effective protection against earth leakage and electrical faults, helping to safeguard both users and connected equipment. Suitable for circuits up to 690V, it is ideal for applications including transformers, control panels, drive systems, and metering installations.\u003c\/p\u003e\n\u003chr data-start=\"991\" data-end=\"994\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"996\" data-end=\"1013\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1014\" data-end=\"1456\"\u003e\n\u003cli data-section-id=\"1hewy8c\" data-start=\"1014\" data-end=\"1060\"\u003e10-module consumer unit with 8 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"xrmwy0\" data-start=\"1061\" data-end=\"1094\"\u003eSupplied with 63A RCD incomer\u003c\/li\u003e\n\u003cli data-section-id=\"ux40hm\" data-start=\"1095\" data-end=\"1162\"\u003eProvides protection against earth leakage and electrical faults\u003c\/li\u003e\n\u003cli data-section-id=\"16wlcj9\" data-start=\"1163\" data-end=\"1199\"\u003eSuitable for circuits up to 690V\u003c\/li\u003e\n\u003cli data-section-id=\"1y9ge7k\" data-start=\"1200\" data-end=\"1271\"\u003eIdeal for transformers, control circuits, and metering applications\u003c\/li\u003e\n\u003cli data-section-id=\"1bdd9s6\" data-start=\"1272\" data-end=\"1310\"\u003eCompact and space-efficient design\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1311\" data-end=\"1348\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"xh6ril\" data-start=\"1349\" data-end=\"1391\"\u003eDurable construction for long-term use\u003c\/li\u003e\n\u003cli data-section-id=\"m6n29i\" data-start=\"1392\" data-end=\"1456\"\u003eSuitable for residential, commercial, and industrial systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1458\" data-end=\"1461\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1463\" data-end=\"1492\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1493\" data-end=\"1727\"\u003e\n\u003cli data-section-id=\"1quqlcx\" data-start=\"1493\" data-end=\"1508\"\u003eSKU: E1008R\u003c\/li\u003e\n\u003cli data-section-id=\"1osty34\" data-start=\"1509\" data-end=\"1534\"\u003eNumber of Modules: 10\u003c\/li\u003e\n\u003cli data-section-id=\"1l5ze2i\" data-start=\"1535\" data-end=\"1553\"\u003eUsable Ways: 8\u003c\/li\u003e\n\u003cli data-section-id=\"wojdqi\" data-start=\"1554\" data-end=\"1579\"\u003eIncomer Type: 63A RCD\u003c\/li\u003e\n\u003cli data-section-id=\"16s2ql\" data-start=\"1580\" data-end=\"1615\"\u003eVoltage Application: Up to 690V\u003c\/li\u003e\n\u003cli data-section-id=\"1k739iu\" data-start=\"1616\" data-end=\"1651\"\u003eType: RCD Incomer Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"kt47le\" data-start=\"1652\" data-end=\"1727\"\u003eApplication: Residential, Commercial, and Industrial Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1729\" data-end=\"1732\"\u003e\n\u003ch2 data-section-id=\"k7ae9a\" data-start=\"1734\" data-end=\"1778\"\u003eWhy Choose a Excel E1008R Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1779\" data-end=\"2018\"\u003eThe Excel E1008R consumer unit is designed for installations where safety is a top priority. Its RCD incomer provides reliable protection against electrical faults, reducing risks and ensuring safer operation across all connected circuits.\u003c\/p\u003e\n\u003cp data-start=\"2020\" data-end=\"2281\"\u003eWith its increased capacity and flexible configuration, it is suitable for a wide range of applications. Its robust build and installer-friendly design make it a dependable choice for professionals seeking efficient and secure electrical distribution solutions.\u003c\/p\u003e\n\u003chr data-start=\"2283\" data-end=\"2286\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2288\" data-end=\"2297\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2299\" data-end=\"2442\"\u003e\u003cstrong data-start=\"2299\" data-end=\"2351\"\u003e1. What is the main advantage of an RCD incomer?\u003c\/strong\u003e\u003cbr data-start=\"2351\" data-end=\"2354\"\u003eIt protects against earth leakage and helps prevent electric shock and equipment damage.\u003c\/p\u003e\n\u003cp data-start=\"2444\" data-end=\"2526\"\u003e\u003cstrong data-start=\"2444\" data-end=\"2491\"\u003e2. How many circuits can this unit support?\u003c\/strong\u003e\u003cbr data-start=\"2491\" data-end=\"2494\"\u003eIt supports up to 8 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2528\" data-end=\"2598\"\u003e\u003cstrong data-start=\"2528\" data-end=\"2565\"\u003e3. What is the rating of the RCD?\u003c\/strong\u003e\u003cbr data-start=\"2565\" data-end=\"2568\"\u003eIt includes a 63A RCD incomer.\u003c\/p\u003e\n\u003cp data-start=\"2600\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2600\" data-end=\"2644\"\u003e4. What applications is it suitable for?\u003c\/strong\u003e\u003cbr data-start=\"2644\" data-end=\"2647\"\u003eIt is suitable for transformers, control systems, metering, and low voltage distribution.\u003c\/p\u003e\n\u003cp data-start=\"2738\" data-end=\"2833\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2738\" data-end=\"2786\"\u003e5. Can it be used for high voltage circuits?\u003c\/strong\u003e\u003cbr data-start=\"2786\" data-end=\"2789\"\u003eYes, it is suitable for circuits up to 690V.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57273653559678,"sku":null,"price":42.43,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-32.png?v=1776466288"},{"product_id":"excel-e1410sa-14-module-rcbo-consumer-unit-with-spd-protection","title":"Excel E1410SA 14 Module RCBO Consumer Unit with SPD Protection","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-83\" data-testid=\"conversation-turn-50\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"3eaa0e18-f4e4-43c0-aa34-f11c9e8bb3a4\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"343\" data-end=\"356\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"357\" data-end=\"752\"\u003eThe Excel E1410SA 14 Module Consumer Unit is a high-performance electrical distribution solution designed for enhanced safety, reliability, and circuit protection. Featuring integrated Surge Protection Device (SPD) and pre-installed RCBOs, it offers advanced protection against both electrical surges and fault currents, making it ideal for modern residential and light commercial installations.\u003c\/p\u003e\n\u003cp data-start=\"754\" data-end=\"1077\"\u003eThis unit is configured with a combination of RCBOs including 1x40A, 3x32A, 2x16A, and 2x6A, ensuring precise circuit management and balanced load distribution. Its 14-module design provides a compact yet efficient layout, making installation straightforward while maintaining a professional and organized electrical setup.\u003c\/p\u003e\n\u003chr data-start=\"1079\" data-end=\"1082\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1084\" data-end=\"1101\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1102\" data-end=\"1622\"\u003e\n\u003cli data-section-id=\"qra8cz\" data-start=\"1102\" data-end=\"1160\"\u003e14-module consumer unit with integrated SPD protection\u003c\/li\u003e\n\u003cli data-section-id=\"onuo4n\" data-start=\"1161\" data-end=\"1217\"\u003ePre-installed RCBO configuration for enhanced safety\u003c\/li\u003e\n\u003cli data-section-id=\"155be55\" data-start=\"1218\" data-end=\"1266\"\u003eIncludes 1x40A, 3x32A, 2x16A, and 2x6A RCBOs\u003c\/li\u003e\n\u003cli data-section-id=\"mrp1l0\" data-start=\"1267\" data-end=\"1332\"\u003eProtection against overload, short circuit, and earth leakage\u003c\/li\u003e\n\u003cli data-section-id=\"1hg4k5z\" data-start=\"1333\" data-end=\"1398\"\u003eBuilt-in Surge Protection Device for voltage spike protection\u003c\/li\u003e\n\u003cli data-section-id=\"1bdd9s6\" data-start=\"1399\" data-end=\"1437\"\u003eCompact and space-efficient design\u003c\/li\u003e\n\u003cli data-section-id=\"1gkt1yy\" data-start=\"1438\" data-end=\"1491\"\u003eSuitable for residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1492\" data-end=\"1529\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1530\" data-end=\"1571\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003cli data-section-id=\"69yftv\" data-start=\"1572\" data-end=\"1622\"\u003eFully compliant protective distribution system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1624\" data-end=\"1627\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1629\" data-end=\"1658\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1659\" data-end=\"1993\"\u003e\n\u003cli data-section-id=\"ln6zhq\" data-start=\"1659\" data-end=\"1677\"\u003eModel: E1410SA\u003c\/li\u003e\n\u003cli data-section-id=\"1osu1g4\" data-start=\"1678\" data-end=\"1703\"\u003eNumber of Modules: 14\u003c\/li\u003e\n\u003cli data-section-id=\"19j81hq\" data-start=\"1704\" data-end=\"1746\"\u003eProtection Type: RCBO + SPD Integrated\u003c\/li\u003e\n\u003cli data-section-id=\"1h9vy8w\" data-start=\"1747\" data-end=\"1790\"\u003eRCBO Ratings: 1x40A, 3x32A, 2x16A, 2x6A\u003c\/li\u003e\n\u003cli data-section-id=\"5b6i8c\" data-start=\"1791\" data-end=\"1825\"\u003eSurge Protection: Built-in SPD\u003c\/li\u003e\n\u003cli data-section-id=\"sodh7y\" data-start=\"1826\" data-end=\"1854\"\u003eType: RCBO Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"kkwbsb\" data-start=\"1855\" data-end=\"1923\"\u003eApplication: Residential and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1au0e2x\" data-start=\"1924\" data-end=\"1993\"\u003eFunction: Circuit Protection, Surge Protection, Load Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1995\" data-end=\"1998\"\u003e\n\u003ch2 data-section-id=\"1rcop43\" data-start=\"2000\" data-end=\"2045\"\u003eWhy Choose a Excel E1410SA Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"2046\" data-end=\"2301\"\u003eThe Excel E1410SA consumer unit is designed for users who require advanced electrical protection in a compact and efficient format. With integrated SPD and RCBOs, it ensures maximum safety by protecting against surges, overloads, and earth leakage faults.\u003c\/p\u003e\n\u003cp data-start=\"2303\" data-end=\"2558\"\u003eIts pre-configured design reduces installation time while providing a balanced and reliable circuit setup. Built for long-term performance, it is an ideal choice for electricians and property owners seeking a modern, fully protected distribution solution.\u003c\/p\u003e\n\u003chr data-start=\"2560\" data-end=\"2563\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2565\" data-end=\"2574\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2576\" data-end=\"2705\"\u003e\u003cstrong data-start=\"2576\" data-end=\"2631\"\u003e1. What protection does this consumer unit provide?\u003c\/strong\u003e\u003cbr data-start=\"2631\" data-end=\"2634\"\u003eIt offers overload, short circuit, earth leakage, and surge protection.\u003c\/p\u003e\n\u003cp data-start=\"2707\" data-end=\"2832\"\u003e\u003cstrong data-start=\"2707\" data-end=\"2754\"\u003e2. Does it include RCBOs already installed?\u003c\/strong\u003e\u003cbr data-start=\"2754\" data-end=\"2757\"\u003eYes, it comes pre-fitted with multiple RCBOs for different circuit ratings.\u003c\/p\u003e\n\u003cp data-start=\"2834\" data-end=\"2942\"\u003e\u003cstrong data-start=\"2834\" data-end=\"2872\"\u003e3. What is the benefit of the SPD?\u003c\/strong\u003e\u003cbr data-start=\"2872\" data-end=\"2875\"\u003eThe SPD protects electrical systems from voltage spikes and surges.\u003c\/p\u003e\n\u003cp data-start=\"2944\" data-end=\"3062\"\u003e\u003cstrong data-start=\"2944\" data-end=\"2991\"\u003e4. Is it suitable for homes and businesses?\u003c\/strong\u003e\u003cbr data-start=\"2991\" data-end=\"2994\"\u003eYes, it is ideal for residential and light commercial installations.\u003c\/p\u003e\n\u003cp data-start=\"3064\" data-end=\"3188\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3064\" data-end=\"3114\"\u003e5. Is installation easier than standard units?\u003c\/strong\u003e\u003cbr data-start=\"3114\" data-end=\"3117\"\u003eYes, its pre-configured design significantly reduces installation time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57273668829566,"sku":null,"price":132.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E1406TR-AS-side.png?v=1776469854"},{"product_id":"excel-e1814sa-18-module-rcbo-consumer-unit-with-spd-protection","title":"Excel E1814SA 18 Module RCBO Consumer Unit with SPD Protection","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-84\" data-testid=\"conversation-turn-52\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"581b7b73-49c1-4c7d-af5a-b0ad8d06deef\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"344\" data-end=\"357\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"358\" data-end=\"750\"\u003eThe Excel E1814SA 18 Module RCBO Consumer Unit is a premium electrical distribution solution designed for enhanced safety, reliability, and performance. Featuring integrated Surge Protection Device (SPD) and pre-installed RCBOs, it delivers complete protection against electrical faults, overloads, and voltage surges, making it ideal for modern residential and light commercial environments.\u003c\/p\u003e\n\u003cp data-start=\"752\" data-end=\"1055\"\u003eWith a well-balanced RCBO configuration of 1x40A, 4x32A, 3x16A, and 2x6A, this unit ensures efficient load distribution across multiple circuits. Its 18-module layout provides additional space for flexible wiring arrangements while maintaining a neat, professional, and organized installation structure.\u003c\/p\u003e\n\u003chr data-start=\"1057\" data-end=\"1060\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1062\" data-end=\"1079\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1080\" data-end=\"1602\"\u003e\n\u003cli data-section-id=\"5nsp28\" data-start=\"1080\" data-end=\"1132\"\u003e18-module RCBO consumer unit with integrated SPD\u003c\/li\u003e\n\u003cli data-section-id=\"3n9024\" data-start=\"1133\" data-end=\"1201\"\u003ePre-installed RCBO configuration for complete circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ablugv\" data-start=\"1202\" data-end=\"1250\"\u003eIncludes 1x40A, 4x32A, 3x16A, and 2x6A RCBOs\u003c\/li\u003e\n\u003cli data-section-id=\"mrp1l0\" data-start=\"1251\" data-end=\"1316\"\u003eProtection against overload, short circuit, and earth leakage\u003c\/li\u003e\n\u003cli data-section-id=\"mpzy14\" data-start=\"1317\" data-end=\"1378\"\u003eBuilt-in Surge Protection Device for voltage spike safety\u003c\/li\u003e\n\u003cli data-section-id=\"26e4ci\" data-start=\"1379\" data-end=\"1415\"\u003eHigh-capacity yet compact design\u003c\/li\u003e\n\u003cli data-section-id=\"1gkt1yy\" data-start=\"1416\" data-end=\"1469\"\u003eSuitable for residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1470\" data-end=\"1507\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1508\" data-end=\"1549\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003cli data-section-id=\"z1ckcq\" data-start=\"1550\" data-end=\"1602\"\u003eFully coordinated protective distribution system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1604\" data-end=\"1607\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1609\" data-end=\"1638\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1639\" data-end=\"1971\"\u003e\n\u003cli data-section-id=\"1djl6w6\" data-start=\"1639\" data-end=\"1657\"\u003eModel: E1814SA\u003c\/li\u003e\n\u003cli data-section-id=\"1osu4t4\" data-start=\"1658\" data-end=\"1683\"\u003eNumber of Modules: 18\u003c\/li\u003e\n\u003cli data-section-id=\"19j81hq\" data-start=\"1684\" data-end=\"1726\"\u003eProtection Type: RCBO + SPD Integrated\u003c\/li\u003e\n\u003cli data-section-id=\"tvketi\" data-start=\"1727\" data-end=\"1770\"\u003eRCBO Ratings: 1x40A, 4x32A, 3x16A, 2x6A\u003c\/li\u003e\n\u003cli data-section-id=\"5b6i8c\" data-start=\"1771\" data-end=\"1805\"\u003eSurge Protection: Built-in SPD\u003c\/li\u003e\n\u003cli data-section-id=\"sodh7y\" data-start=\"1806\" data-end=\"1834\"\u003eType: RCBO Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"kkwbsb\" data-start=\"1835\" data-end=\"1903\"\u003eApplication: Residential and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1mg9u3k\" data-start=\"1904\" data-end=\"1971\"\u003eFunction: Circuit Protection, Surge Protection, Load Management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1973\" data-end=\"1976\"\u003e\n\u003ch2 data-section-id=\"1ol0x0r\" data-start=\"1978\" data-end=\"2023\"\u003eWhy Choose a Excel E1814SA Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"2024\" data-end=\"2263\"\u003eThe Excel E1814SA consumer unit is designed for installations requiring higher circuit capacity and advanced protection features. With integrated SPD and multiple RCBOs, it ensures maximum safety against electrical faults and power surges.\u003c\/p\u003e\n\u003cp data-start=\"2265\" data-end=\"2550\"\u003eIts pre-configured layout simplifies installation while providing a highly efficient and balanced electrical distribution system. Built for reliability and long-term performance, it is an excellent choice for electricians and property owners seeking a modern, fully protected solution.\u003c\/p\u003e\n\u003chr data-start=\"2552\" data-end=\"2555\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2557\" data-end=\"2566\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2568\" data-end=\"2713\"\u003e\u003cstrong data-start=\"2568\" data-end=\"2622\"\u003e1. What type of protection does this unit provide?\u003c\/strong\u003e\u003cbr data-start=\"2622\" data-end=\"2625\"\u003eIt provides protection against overload, short circuit, earth leakage, and power surges.\u003c\/p\u003e\n\u003cp data-start=\"2715\" data-end=\"2831\"\u003e\u003cstrong data-start=\"2715\" data-end=\"2759\"\u003e2. Are RCBOs pre-installed in this unit?\u003c\/strong\u003e\u003cbr data-start=\"2759\" data-end=\"2762\"\u003eYes, it comes with multiple pre-installed RCBOs in different ratings.\u003c\/p\u003e\n\u003cp data-start=\"2833\" data-end=\"2951\"\u003e\u003cstrong data-start=\"2833\" data-end=\"2871\"\u003e3. What is the purpose of the SPD?\u003c\/strong\u003e\u003cbr data-start=\"2871\" data-end=\"2874\"\u003eThe SPD protects electrical systems from voltage spikes and transient surges.\u003c\/p\u003e\n\u003cp data-start=\"2953\" data-end=\"3062\"\u003e\u003cstrong data-start=\"2953\" data-end=\"2997\"\u003e4. Is this suitable for residential use?\u003c\/strong\u003e\u003cbr data-start=\"2997\" data-end=\"3000\"\u003eYes, it is ideal for homes and light commercial installations.\u003c\/p\u003e\n\u003cp data-start=\"3064\" data-end=\"3190\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3064\" data-end=\"3104\"\u003e5. Does it reduce installation time?\u003c\/strong\u003e\u003cbr data-start=\"3104\" data-end=\"3107\"\u003eYes, its pre-configured design significantly simplifies and speeds up installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57273678922110,"sku":null,"price":158.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-33.png?v=1776470048"},{"product_id":"excel-e1406trs-dual-rcd-consumer-unit-with-spd-protection","title":"Excel E1406TRS Dual RCD Consumer Unit with SPD Protection","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-85\" data-testid=\"conversation-turn-54\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"d07c2f0e-b969-4c4f-9909-66349a66bc19\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"334\" data-end=\"347\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"348\" data-end=\"679\"\u003eThe Excel E1406TRS Dual RCD Consumer Unit with SPD is a compact yet highly secure electrical distribution solution designed for modern residential and light commercial installations. Featuring a 14-module enclosure with 6 usable ways, it delivers efficient circuit management while maintaining a structured and space-saving layout.\u003c\/p\u003e\n\u003cp data-start=\"681\" data-end=\"1041\"\u003eEquipped with twin 63A 30mA RCDs, a 100A main switch, and an integrated Surge Protection Device (SPD), this consumer unit provides comprehensive protection against electrical faults, overloads, and voltage surges. It is designed to ensure maximum safety for both users and connected electrical equipment, making it a reliable choice for everyday installations.\u003c\/p\u003e\n\u003chr data-start=\"1043\" data-end=\"1046\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1048\" data-end=\"1065\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1066\" data-end=\"1568\"\u003e\n\u003cli data-section-id=\"1ssy7bh\" data-start=\"1066\" data-end=\"1122\"\u003e14-module dual RCD consumer unit with SPD protection\u003c\/li\u003e\n\u003cli data-section-id=\"o31s3p\" data-start=\"1123\" data-end=\"1175\"\u003e6 usable ways for efficient circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1jugry0\" data-start=\"1176\" data-end=\"1228\"\u003eTwin 63A 30mA RCD protection for enhanced safety\u003c\/li\u003e\n\u003cli data-section-id=\"3le9fu\" data-start=\"1229\" data-end=\"1284\"\u003e100A main switch for reliable isolation and control\u003c\/li\u003e\n\u003cli data-section-id=\"78tfo4\" data-start=\"1285\" data-end=\"1329\"\u003eIntegrated Surge Protection Device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"mrp1l0\" data-start=\"1330\" data-end=\"1395\"\u003eProtection against overload, short circuit, and earth leakage\u003c\/li\u003e\n\u003cli data-section-id=\"1bdd9s6\" data-start=\"1396\" data-end=\"1434\"\u003eCompact and space-efficient design\u003c\/li\u003e\n\u003cli data-section-id=\"1gkt1yy\" data-start=\"1435\" data-end=\"1488\"\u003eSuitable for residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1489\" data-end=\"1526\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1527\" data-end=\"1568\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1570\" data-end=\"1573\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1575\" data-end=\"1604\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1605\" data-end=\"1930\"\u003e\n\u003cli data-section-id=\"r4g3u4\" data-start=\"1605\" data-end=\"1622\"\u003eSKU: E1406TRS\u003c\/li\u003e\n\u003cli data-section-id=\"1osu1g4\" data-start=\"1623\" data-end=\"1648\"\u003eNumber of Modules: 14\u003c\/li\u003e\n\u003cli data-section-id=\"1l5z910\" data-start=\"1649\" data-end=\"1667\"\u003eUsable Ways: 6\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1668\" data-end=\"1696\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1hxinxr\" data-start=\"1697\" data-end=\"1726\"\u003eRCD Rating: Twin 63A 30mA\u003c\/li\u003e\n\u003cli data-section-id=\"181dxef\" data-start=\"1727\" data-end=\"1763\"\u003eSurge Protection: Integrated SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1qpb3uj\" data-start=\"1764\" data-end=\"1796\"\u003eType: Dual RCD Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1797\" data-end=\"1862\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003cli data-section-id=\"8pz6t3\" data-start=\"1863\" data-end=\"1930\"\u003eProtection Functions: Overload, Earth Leakage, Surge Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1932\" data-end=\"1935\"\u003e\n\u003ch2 data-section-id=\"17w4gpv\" data-start=\"1937\" data-end=\"1983\"\u003eWhy Choose a Excel E1406TRS Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1984\" data-end=\"2239\"\u003eThe Excel E1406TRS consumer unit is designed for users who require enhanced safety and dependable performance in a compact format. Its dual RCD configuration ensures effective fault protection across multiple circuits, improving overall electrical safety.\u003c\/p\u003e\n\u003cp data-start=\"2241\" data-end=\"2520\"\u003eWith integrated SPD and a robust build, it offers reliable protection against both electrical surges and faults. Its user-friendly design reduces installation time, making it an ideal choice for electricians and property owners seeking a safe and efficient distribution solution.\u003c\/p\u003e\n\u003chr data-start=\"2522\" data-end=\"2525\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2527\" data-end=\"2536\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2538\" data-end=\"2685\"\u003e\u003cstrong data-start=\"2538\" data-end=\"2593\"\u003e1. What protection does this consumer unit provide?\u003c\/strong\u003e\u003cbr data-start=\"2593\" data-end=\"2596\"\u003eIt provides protection against overload, earth leakage, short circuits, and power surges.\u003c\/p\u003e\n\u003cp data-start=\"2687\" data-end=\"2762\"\u003e\u003cstrong data-start=\"2687\" data-end=\"2727\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2727\" data-end=\"2730\"\u003eIt supports up to 6 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2764\" data-end=\"2896\"\u003e\u003cstrong data-start=\"2764\" data-end=\"2815\"\u003e3. What is the function of the dual RCD system?\u003c\/strong\u003e\u003cbr data-start=\"2815\" data-end=\"2818\"\u003eIt divides protection across circuits for improved safety and fault isolation.\u003c\/p\u003e\n\u003cp data-start=\"2898\" data-end=\"3007\"\u003e\u003cstrong data-start=\"2898\" data-end=\"2938\"\u003e4. Does it include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2938\" data-end=\"2941\"\u003eYes, it comes with an integrated SPD for voltage surge protection.\u003c\/p\u003e\n\u003cp data-start=\"3009\" data-end=\"3124\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3009\" data-end=\"3054\"\u003e5. Is it suitable for home installations?\u003c\/strong\u003e\u003cbr data-start=\"3054\" data-end=\"3057\"\u003eYes, it is ideal for residential and light commercial applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57273688916350,"sku":null,"price":84.03,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-29.png?v=1776470362"},{"product_id":"excel-e1810trs-dual-rcd-consumer-unit-with-spd-protection","title":"Excel E1810TRS Dual RCD Consumer Unit with SPD Protection","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-86\" data-testid=\"conversation-turn-56\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"ace08630-c3d8-43c1-92e9-529cb1afac0d\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"341\" data-end=\"354\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"355\" data-end=\"693\"\u003eThe Excel E1810TRS Dual RCD Consumer Unit with SPD is a reliable and high-performance electrical distribution solution designed for residential and light commercial installations. With an 18-module enclosure and 10 usable ways, it offers excellent flexibility for managing multiple circuits while maintaining a clean and organized layout.\u003c\/p\u003e\n\u003cp data-start=\"695\" data-end=\"1045\"\u003eEquipped with twin 63A 30mA RCDs, a 100A main switch, and an integrated Surge Protection Device (SPD), this unit delivers comprehensive protection against electrical faults, overloads, and voltage surges. It ensures safe and stable power distribution, making it an ideal choice for modern electrical systems requiring enhanced safety and reliability.\u003c\/p\u003e\n\u003chr data-start=\"1047\" data-end=\"1050\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1052\" data-end=\"1069\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1070\" data-end=\"1577\"\u003e\n\u003cli data-section-id=\"1jflm69\" data-start=\"1070\" data-end=\"1126\"\u003e18-module dual RCD consumer unit with SPD protection\u003c\/li\u003e\n\u003cli data-section-id=\"lnd4ta\" data-start=\"1127\" data-end=\"1179\"\u003e10 usable ways for flexible circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"mue9kt\" data-start=\"1180\" data-end=\"1232\"\u003eTwin 63A 30mA RCDs for enhanced fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"1i6vc03\" data-start=\"1233\" data-end=\"1284\"\u003e100A main switch for safe isolation and control\u003c\/li\u003e\n\u003cli data-section-id=\"78tfo4\" data-start=\"1285\" data-end=\"1329\"\u003eIntegrated Surge Protection Device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"mrp1l0\" data-start=\"1330\" data-end=\"1395\"\u003eProtection against overload, short circuit, and earth leakage\u003c\/li\u003e\n\u003cli data-section-id=\"1bdd9s6\" data-start=\"1396\" data-end=\"1434\"\u003eCompact and space-efficient design\u003c\/li\u003e\n\u003cli data-section-id=\"1s3haq8\" data-start=\"1435\" data-end=\"1497\"\u003eSuitable for residential and light commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1498\" data-end=\"1535\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1536\" data-end=\"1577\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1579\" data-end=\"1582\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1584\" data-end=\"1613\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1614\" data-end=\"1940\"\u003e\n\u003cli data-section-id=\"176prvr\" data-start=\"1614\" data-end=\"1631\"\u003eSKU: E1810TRS\u003c\/li\u003e\n\u003cli data-section-id=\"1osu4t4\" data-start=\"1632\" data-end=\"1657\"\u003eNumber of Modules: 18\u003c\/li\u003e\n\u003cli data-section-id=\"13oe76r\" data-start=\"1658\" data-end=\"1677\"\u003eUsable Ways: 10\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1678\" data-end=\"1706\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1hxinxr\" data-start=\"1707\" data-end=\"1736\"\u003eRCD Rating: Twin 63A 30mA\u003c\/li\u003e\n\u003cli data-section-id=\"181dxef\" data-start=\"1737\" data-end=\"1773\"\u003eSurge Protection: Integrated SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1qpb3uj\" data-start=\"1774\" data-end=\"1806\"\u003eType: Dual RCD Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1807\" data-end=\"1872\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003cli data-section-id=\"8pz6t3\" data-start=\"1873\" data-end=\"1940\"\u003eProtection Functions: Overload, Earth Leakage, Surge Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1942\" data-end=\"1945\"\u003e\n\u003ch2 data-section-id=\"q46t60\" data-start=\"1947\" data-end=\"1993\"\u003eWhy Choose a Excel E1810TRS Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1994\" data-end=\"2233\"\u003eThe Excel E1810TRS consumer unit is designed for installations that require a balance of capacity, safety, and performance. Its dual RCD system ensures reliable fault isolation, improving overall electrical safety across multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"2235\" data-end=\"2493\"\u003eWith integrated SPD protection and a durable, installer-friendly design, it offers dependable long-term performance. It is a practical solution for electricians and property owners seeking a safe and efficient distribution system for modern electrical needs.\u003c\/p\u003e\n\u003chr data-start=\"2495\" data-end=\"2498\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2500\" data-end=\"2509\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2511\" data-end=\"2657\"\u003e\u003cstrong data-start=\"2511\" data-end=\"2565\"\u003e1. What type of protection does this unit provide?\u003c\/strong\u003e\u003cbr data-start=\"2565\" data-end=\"2568\"\u003eIt provides protection against overload, short circuits, earth leakage, and power surges.\u003c\/p\u003e\n\u003cp data-start=\"2659\" data-end=\"2735\"\u003e\u003cstrong data-start=\"2659\" data-end=\"2699\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2699\" data-end=\"2702\"\u003eIt supports up to 10 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2737\" data-end=\"2870\"\u003e\u003cstrong data-start=\"2737\" data-end=\"2777\"\u003e3. What is the benefit of dual RCDs?\u003c\/strong\u003e\u003cbr data-start=\"2777\" data-end=\"2780\"\u003eThey improve safety by splitting circuit protection and isolating faults more effectively.\u003c\/p\u003e\n\u003cp data-start=\"2872\" data-end=\"2981\"\u003e\u003cstrong data-start=\"2872\" data-end=\"2912\"\u003e4. Does it include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2912\" data-end=\"2915\"\u003eYes, it comes with an integrated SPD for voltage surge protection.\u003c\/p\u003e\n\u003cp data-start=\"2983\" data-end=\"3089\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2983\" data-end=\"3018\"\u003e5. Is it suitable for home use?\u003c\/strong\u003e\u003cbr data-start=\"3018\" data-end=\"3021\"\u003eYes, it is ideal for residential and light commercial installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57273886703998,"sku":null,"price":95.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E1810TRS-side.png?v=1776474547"},{"product_id":"excel-e2416trs-dual-rcd-consumer-unit-with-spd-protection","title":"Excel E2416TRS Dual RCD Consumer Unit with SPD Protection","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-87\" data-testid=\"conversation-turn-58\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"0485bc7f-3be9-4036-8ab7-af3ee6f89641\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"337\" data-end=\"350\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"351\" data-end=\"701\"\u003eThe Excel E2416TRS Dual RCD Consumer Unit with SPD is a high-capacity and safety-focused electrical distribution solution designed for modern residential and light commercial installations. With a 24-module enclosure and 16 usable ways, it provides excellent flexibility for managing multiple circuits while maintaining a clean and structured layout.\u003c\/p\u003e\n\u003cp data-start=\"703\" data-end=\"1009\"\u003eEquipped with twin 80A 30mA RCDs, a 100A main switch, and an integrated Surge Protection Device (SPD), this unit ensures comprehensive protection against electrical faults, overloads, and voltage surges. It is engineered to deliver reliable performance and enhanced safety for demanding electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"1011\" data-end=\"1014\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1016\" data-end=\"1033\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1034\" data-end=\"1545\"\u003e\n\u003cli data-section-id=\"1aj288e\" data-start=\"1034\" data-end=\"1090\"\u003e24-module dual RCD consumer unit with SPD protection\u003c\/li\u003e\n\u003cli data-section-id=\"2bofxt\" data-start=\"1091\" data-end=\"1141\"\u003e16 usable ways for flexible circuit management\u003c\/li\u003e\n\u003cli data-section-id=\"w73lsw\" data-start=\"1142\" data-end=\"1194\"\u003eTwin 80A 30mA RCDs for improved fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"1i6vc03\" data-start=\"1195\" data-end=\"1246\"\u003e100A main switch for safe isolation and control\u003c\/li\u003e\n\u003cli data-section-id=\"78tfo4\" data-start=\"1247\" data-end=\"1291\"\u003eIntegrated Surge Protection Device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"mrp1l0\" data-start=\"1292\" data-end=\"1357\"\u003eProtection against overload, short circuit, and earth leakage\u003c\/li\u003e\n\u003cli data-section-id=\"wa6jau\" data-start=\"1358\" data-end=\"1402\"\u003eHigh-capacity and space-efficient design\u003c\/li\u003e\n\u003cli data-section-id=\"1s3haq8\" data-start=\"1403\" data-end=\"1465\"\u003eSuitable for residential and light commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1466\" data-end=\"1503\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1504\" data-end=\"1545\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1547\" data-end=\"1550\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1552\" data-end=\"1581\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1582\" data-end=\"1908\"\u003e\n\u003cli data-section-id=\"tmlii6\" data-start=\"1582\" data-end=\"1599\"\u003eSKU: E2416TRS\u003c\/li\u003e\n\u003cli data-section-id=\"1osxugn\" data-start=\"1600\" data-end=\"1625\"\u003eNumber of Modules: 24\u003c\/li\u003e\n\u003cli data-section-id=\"13oe8v9\" data-start=\"1626\" data-end=\"1645\"\u003eUsable Ways: 16\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1646\" data-end=\"1674\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"yopduq\" data-start=\"1675\" data-end=\"1704\"\u003eRCD Rating: Twin 80A 30mA\u003c\/li\u003e\n\u003cli data-section-id=\"181dxef\" data-start=\"1705\" data-end=\"1741\"\u003eSurge Protection: Integrated SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1qpb3uj\" data-start=\"1742\" data-end=\"1774\"\u003eType: Dual RCD Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1775\" data-end=\"1840\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003cli data-section-id=\"8pz6t3\" data-start=\"1841\" data-end=\"1908\"\u003eProtection Functions: Overload, Earth Leakage, Surge Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1910\" data-end=\"1913\"\u003e\n\u003ch2 data-section-id=\"hvt76p\" data-start=\"1915\" data-end=\"1961\"\u003eWhy Choose a Excel E2416TRS Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1962\" data-end=\"2197\"\u003eThe Excel E2416TRS consumer unit is designed for installations that require higher capacity and enhanced protection. Its dual RCD configuration ensures reliable fault isolation, improving overall system safety across multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"2199\" data-end=\"2445\"\u003eWith integrated SPD and a robust design, it provides long-term reliability and protection against electrical surges and faults. It is an excellent choice for electricians and property owners seeking a powerful and efficient distribution solution.\u003c\/p\u003e\n\u003chr data-start=\"2447\" data-end=\"2450\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2452\" data-end=\"2461\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2463\" data-end=\"2608\"\u003e\u003cstrong data-start=\"2463\" data-end=\"2516\"\u003e1. What protection does this consumer unit offer?\u003c\/strong\u003e\u003cbr data-start=\"2516\" data-end=\"2519\"\u003eIt provides protection against overload, short circuits, earth leakage, and power surges.\u003c\/p\u003e\n\u003cp data-start=\"2610\" data-end=\"2686\"\u003e\u003cstrong data-start=\"2610\" data-end=\"2650\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2650\" data-end=\"2653\"\u003eIt supports up to 16 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2688\" data-end=\"2820\"\u003e\u003cstrong data-start=\"2688\" data-end=\"2728\"\u003e3. What is the benefit of twin RCDs?\u003c\/strong\u003e\u003cbr data-start=\"2728\" data-end=\"2731\"\u003eThey improve safety by dividing circuit protection and isolating faults more effectively.\u003c\/p\u003e\n\u003cp data-start=\"2822\" data-end=\"2902\"\u003e\u003cstrong data-start=\"2822\" data-end=\"2862\"\u003e4. Does it include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2862\" data-end=\"2865\"\u003eYes, it comes with an integrated SPD.\u003c\/p\u003e\n\u003cp data-start=\"2904\" data-end=\"3011\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2904\" data-end=\"2946\"\u003e5. Is it suitable for residential use?\u003c\/strong\u003e\u003cbr data-start=\"2946\" data-end=\"2949\"\u003eYes, it is ideal for homes and light commercial installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57273913213310,"sku":null,"price":107.32,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E2416TRS-side.png?v=1776474942"},{"product_id":"excel-e1812tr-dual-rcd-consumer-unit-18-module-12-way","title":"Excel E1812TR Dual RCD Consumer Unit 18 Module 12 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-89\" data-testid=\"conversation-turn-62\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"ac791e99-8d6a-4ccb-833c-bbe264423483\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"339\" data-end=\"352\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"353\" data-end=\"679\"\u003eThe Excel E1812TR Dual RCD Consumer Unit is a robust and efficient electrical distribution solution designed for residential and light commercial applications. With an 18-module enclosure and 12 usable ways, it provides ample capacity for managing multiple circuits while maintaining a clean and organized installation layout.\u003c\/p\u003e\n\u003cp data-start=\"681\" data-end=\"971\"\u003eEquipped with twin 63A 30mA RCDs and a 100A main switch, this consumer unit delivers reliable protection against electrical faults and overloads. Its dual RCD configuration enhances safety by isolating circuit groups effectively, making it a dependable choice for modern electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"973\" data-end=\"976\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"978\" data-end=\"995\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"996\" data-end=\"1466\"\u003e\n\u003cli data-section-id=\"67bf9\" data-start=\"996\" data-end=\"1039\"\u003e18-module dual RCD consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"arv9jw\" data-start=\"1040\" data-end=\"1092\"\u003e12 usable ways for flexible circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1bmufht\" data-start=\"1093\" data-end=\"1125\"\u003eTwin 63A 30mA RCD protection\u003c\/li\u003e\n\u003cli data-section-id=\"1i6vc03\" data-start=\"1126\" data-end=\"1177\"\u003e100A main switch for safe isolation and control\u003c\/li\u003e\n\u003cli data-section-id=\"mrp1l0\" data-start=\"1178\" data-end=\"1243\"\u003eProtection against overload, short circuit, and earth leakage\u003c\/li\u003e\n\u003cli data-section-id=\"t5ogni\" data-start=\"1244\" data-end=\"1285\"\u003eCompact and space-efficient enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1gkt1yy\" data-start=\"1286\" data-end=\"1339\"\u003eSuitable for residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1340\" data-end=\"1377\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1378\" data-end=\"1419\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003cli data-section-id=\"1ejvbio\" data-start=\"1420\" data-end=\"1466\"\u003eClean and organized internal wiring layout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1468\" data-end=\"1471\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1473\" data-end=\"1502\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1503\" data-end=\"1802\"\u003e\n\u003cli data-section-id=\"1lb4uuu\" data-start=\"1503\" data-end=\"1519\"\u003eSKU: E1812TR\u003c\/li\u003e\n\u003cli data-section-id=\"1osu4t4\" data-start=\"1520\" data-end=\"1545\"\u003eNumber of Modules: 18\u003c\/li\u003e\n\u003cli data-section-id=\"13oe5i9\" data-start=\"1546\" data-end=\"1565\"\u003eUsable Ways: 12\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1566\" data-end=\"1594\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1hxinxr\" data-start=\"1595\" data-end=\"1624\"\u003eRCD Rating: Twin 63A 30mA\u003c\/li\u003e\n\u003cli data-section-id=\"15kig9d\" data-start=\"1625\" data-end=\"1671\"\u003eType: Dual RCD Consumer Unit (Without SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1672\" data-end=\"1737\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1l00zlv\" data-start=\"1738\" data-end=\"1802\"\u003eProtection Functions: Overload, Earth Leakage, Short Circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1804\" data-end=\"1807\"\u003e\n\u003ch2 data-section-id=\"1ifnu3d\" data-start=\"1809\" data-end=\"1854\"\u003eWhy Choose a Excel E1812TR Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1855\" data-end=\"2094\"\u003eThe Excel E1812TR consumer unit is designed for installations that require a balance of capacity, safety, and reliability. Its dual RCD system ensures effective fault isolation, improving overall electrical safety across multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"2096\" data-end=\"2334\"\u003eWith its durable construction and installer-friendly design, it offers long-term performance and ease of installation. It is a practical choice for electricians and property owners seeking a dependable and efficient distribution solution.\u003c\/p\u003e\n\u003chr data-start=\"2336\" data-end=\"2339\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2341\" data-end=\"2350\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2352\" data-end=\"2447\"\u003e\u003cstrong data-start=\"2352\" data-end=\"2408\"\u003e1. Does this consumer unit include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2408\" data-end=\"2411\"\u003eNo, this model does not include SPD.\u003c\/p\u003e\n\u003cp data-start=\"2449\" data-end=\"2525\"\u003e\u003cstrong data-start=\"2449\" data-end=\"2489\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2489\" data-end=\"2492\"\u003eIt supports up to 12 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2527\" data-end=\"2661\"\u003e\u003cstrong data-start=\"2527\" data-end=\"2583\"\u003e3. What protection does the dual RCD system provide?\u003c\/strong\u003e\u003cbr data-start=\"2583\" data-end=\"2586\"\u003eIt provides protection against overload, earth leakage, and short circuits.\u003c\/p\u003e\n\u003cp data-start=\"2663\" data-end=\"2737\"\u003e\u003cstrong data-start=\"2663\" data-end=\"2701\"\u003e4. What is the main switch rating?\u003c\/strong\u003e\u003cbr data-start=\"2701\" data-end=\"2704\"\u003eIt comes with a 100A main switch.\u003c\/p\u003e\n\u003cp data-start=\"2739\" data-end=\"2846\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2739\" data-end=\"2781\"\u003e5. Is it suitable for residential use?\u003c\/strong\u003e\u003cbr data-start=\"2781\" data-end=\"2784\"\u003eYes, it is ideal for homes and light commercial installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57274007847294,"sku":null,"price":85.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E1812TR-side.png?v=1776477205"},{"product_id":"excel-e2418tr-dual-rcd-consumer-unit-24-module-18-way","title":"Excel E2418TR Dual RCD Consumer Unit 24 Module 18 Way","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:d2f2e08c-b739-40aa-b991-50692a92308c-90\" data-testid=\"conversation-turn-64\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"3f0ab92f-5a88-4e6d-843f-bfb8bd59ab35\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"6lznae\" data-start=\"330\" data-end=\"343\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"344\" data-end=\"704\"\u003eThe Excel E2418TR Dual RCD Consumer Unit is a high-capacity electrical distribution solution designed for safe and efficient power management in residential and light commercial installations. With a 24-module enclosure and 18 usable ways, it provides excellent flexibility for handling multiple circuits while maintaining a structured and professional layout.\u003c\/p\u003e\n\u003cp data-start=\"706\" data-end=\"1048\"\u003eEquipped with twin 80A 30mA RCDs and a 100A main switch, this consumer unit delivers strong protection against electrical faults, overloads, and earth leakage. Its dual RCD configuration enhances safety by isolating circuit groups effectively, making it a dependable choice for modern electrical systems requiring reliability and performance.\u003c\/p\u003e\n\u003chr data-start=\"1050\" data-end=\"1053\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1055\" data-end=\"1072\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1073\" data-end=\"1552\"\u003e\n\u003cli data-section-id=\"1vybvx6\" data-start=\"1073\" data-end=\"1116\"\u003e24-module dual RCD consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"mhed1y\" data-start=\"1117\" data-end=\"1169\"\u003e18 usable ways for flexible circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1an2ajg\" data-start=\"1170\" data-end=\"1202\"\u003eTwin 80A 30mA RCD protection\u003c\/li\u003e\n\u003cli data-section-id=\"1i6vc03\" data-start=\"1203\" data-end=\"1254\"\u003e100A main switch for safe isolation and control\u003c\/li\u003e\n\u003cli data-section-id=\"mrp1l0\" data-start=\"1255\" data-end=\"1320\"\u003eProtection against overload, short circuit, and earth leakage\u003c\/li\u003e\n\u003cli data-section-id=\"t5ogni\" data-start=\"1321\" data-end=\"1362\"\u003eCompact and space-efficient enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1s3haq8\" data-start=\"1363\" data-end=\"1425\"\u003eSuitable for residential and light commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"f8hmgc\" data-start=\"1426\" data-end=\"1463\"\u003eEasy installation and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1464\" data-end=\"1505\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003cli data-section-id=\"1ejvbio\" data-start=\"1506\" data-end=\"1552\"\u003eClean and organized internal wiring layout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1554\" data-end=\"1557\"\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1559\" data-end=\"1588\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1589\" data-end=\"1888\"\u003e\n\u003cli data-section-id=\"1r4c2s3\" data-start=\"1589\" data-end=\"1605\"\u003eSKU: E2418TR\u003c\/li\u003e\n\u003cli data-section-id=\"1osxugn\" data-start=\"1606\" data-end=\"1631\"\u003eNumber of Modules: 24\u003c\/li\u003e\n\u003cli data-section-id=\"13oedwr\" data-start=\"1632\" data-end=\"1651\"\u003eUsable Ways: 18\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1652\" data-end=\"1680\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"yopduq\" data-start=\"1681\" data-end=\"1710\"\u003eRCD Rating: Twin 80A 30mA\u003c\/li\u003e\n\u003cli data-section-id=\"15kig9d\" data-start=\"1711\" data-end=\"1757\"\u003eType: Dual RCD Consumer Unit (Without SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"7224on\" data-start=\"1758\" data-end=\"1823\"\u003eApplication: Domestic and Light Commercial Electrical Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1l00zlv\" data-start=\"1824\" data-end=\"1888\"\u003eProtection Functions: Overload, Earth Leakage, Short Circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1890\" data-end=\"1893\"\u003e\n\u003ch2 data-section-id=\"207dj0\" data-start=\"1895\" data-end=\"1940\"\u003eWhy Choose a Excel E2418TR Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1941\" data-end=\"2179\"\u003eThe Excel E2418TR consumer unit is ideal for installations that require higher circuit capacity with reliable dual-layer protection. Its dual RCD system ensures effective fault isolation, improving overall safety across multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"2181\" data-end=\"2419\"\u003eWith its durable build and installer-friendly design, it offers long-term reliability and ease of installation. It is a practical and efficient solution for electricians and property owners seeking a robust electrical distribution system.\u003c\/p\u003e\n\u003chr data-start=\"2421\" data-end=\"2424\"\u003e\n\u003ch2 data-section-id=\"w36ijk\" data-start=\"2426\" data-end=\"2435\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2437\" data-end=\"2532\"\u003e\u003cstrong data-start=\"2437\" data-end=\"2493\"\u003e1. Does this consumer unit include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2493\" data-end=\"2496\"\u003eNo, this model does not include SPD.\u003c\/p\u003e\n\u003cp data-start=\"2534\" data-end=\"2610\"\u003e\u003cstrong data-start=\"2534\" data-end=\"2574\"\u003e2. How many circuits can it support?\u003c\/strong\u003e\u003cbr data-start=\"2574\" data-end=\"2577\"\u003eIt supports up to 18 usable ways.\u003c\/p\u003e\n\u003cp data-start=\"2612\" data-end=\"2736\"\u003e\u003cstrong data-start=\"2612\" data-end=\"2652\"\u003e3. What is the purpose of dual RCDs?\u003c\/strong\u003e\u003cbr data-start=\"2652\" data-end=\"2655\"\u003eThey provide improved safety by isolating faults across different circuit groups.\u003c\/p\u003e\n\u003cp data-start=\"2738\" data-end=\"2812\"\u003e\u003cstrong data-start=\"2738\" data-end=\"2776\"\u003e4. What is the main switch rating?\u003c\/strong\u003e\u003cbr data-start=\"2776\" data-end=\"2779\"\u003eIt comes with a 100A main switch.\u003c\/p\u003e\n\u003cp data-start=\"2814\" data-end=\"2930\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2814\" data-end=\"2852\"\u003e5. Is it suitable for large homes?\u003c\/strong\u003e\u003cbr data-start=\"2852\" data-end=\"2855\"\u003eYes, it is ideal for larger residential and light commercial installations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57274018955646,"sku":null,"price":96.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E2418S-side_7c440a7a-d9c4-4816-90cf-697e394b39c2.png?v=1776477472"},{"product_id":"dual-rcd-consumer-unit-with-spd-6-way-populated-board","title":"Dual RCD Consumer Unit with SPD – 6 Way Populated Board","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-91\" data-testid=\"conversation-turn-2\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"4daa57e6-fc01-47a4-ae6b-58b37f0db40b\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"337\" data-end=\"356\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"358\" data-end=\"831\"\u003eThe Dual RCD Consumer Unit with SPD (E1406TR-AS) is a reliable and efficient solution designed to deliver enhanced electrical protection for residential and light commercial installations. Built with a 14-module enclosure and 6 usable ways, this fully populated board comes pre-configured with MCBs, making installation faster and more convenient. Its dual RCD setup ensures improved circuit separation, minimizing disruption during faults while maintaining optimal safety.\u003c\/p\u003e\n\u003cp data-start=\"833\" data-end=\"1200\"\u003eEquipped with a Type A 63A RCD and an integrated Surge Protection Device (SPD), this consumer unit safeguards sensitive electrical equipment from transient overvoltages. The thoughtful configuration of breakers (2x6A, 1x16A, 3x32A) makes it suitable for a variety of circuit requirements, providing flexibility and dependable performance in modern electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"1202\" data-end=\"1205\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1207\" data-end=\"1222\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1224\" data-end=\"1701\"\u003e\n\u003cli data-section-id=\"1hhw8ew\" data-start=\"1224\" data-end=\"1288\"\u003eFully populated dual RCD consumer unit for easy installation\u003c\/li\u003e\n\u003cli data-section-id=\"iihn1\" data-start=\"1289\" data-end=\"1340\"\u003e6 usable ways within a compact 14-module design\u003c\/li\u003e\n\u003cli data-section-id=\"1lb5reb\" data-start=\"1341\" data-end=\"1402\"\u003eIntegrated Surge Protection Device (SPD) for added safety\u003c\/li\u003e\n\u003cli data-section-id=\"5dgucq\" data-start=\"1403\" data-end=\"1451\"\u003e63A Type A RCD for reliable fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"mi8op7\" data-start=\"1452\" data-end=\"1514\"\u003ePre-installed MCB configuration for versatile applications\u003c\/li\u003e\n\u003cli data-section-id=\"101v86o\" data-start=\"1515\" data-end=\"1583\"\u003eDurable construction suitable for residential and commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"nvlp1g\" data-start=\"1584\" data-end=\"1647\"\u003eEfficient circuit separation reduces downtime during faults\u003c\/li\u003e\n\u003cli data-section-id=\"bx2334\" data-start=\"1648\" data-end=\"1701\"\u003eCompliant with modern electrical safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1703\" data-end=\"1706\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1708\" data-end=\"1735\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1737\" data-end=\"2083\"\u003e\n\u003cli data-section-id=\"qfos02\" data-start=\"1737\" data-end=\"1758\"\u003eModel: E1406TR-AS\u003c\/li\u003e\n\u003cli data-section-id=\"1ku9cea\" data-start=\"1759\" data-end=\"1792\"\u003eNumber of Ways: 6 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"12ud1h8\" data-start=\"1793\" data-end=\"1831\"\u003eTotal Modules: 14 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"rw4z8m\" data-start=\"1832\" data-end=\"1852\"\u003eRCD Type: Type A\u003c\/li\u003e\n\u003cli data-section-id=\"1jh8x38\" data-start=\"1853\" data-end=\"1872\"\u003eRCD Rating: 63A\u003c\/li\u003e\n\u003cli data-section-id=\"181dxef\" data-start=\"1873\" data-end=\"1909\"\u003eSurge Protection: Integrated SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1bs36ls\" data-start=\"1910\" data-end=\"1973\"\u003eMCB Configuration:\n\u003cul data-start=\"1935\" data-end=\"1973\"\u003e\n\u003cli data-section-id=\"6ts4d1\" data-start=\"1935\" data-end=\"1945\"\u003e2 x 6A\u003c\/li\u003e\n\u003cli data-section-id=\"4x5w4n\" data-start=\"1948\" data-end=\"1959\"\u003e1 x 16A\u003c\/li\u003e\n\u003cli data-section-id=\"1xirdcz\" data-start=\"1962\" data-end=\"1973\"\u003e3 x 32A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v3qqkc\" data-start=\"1974\" data-end=\"2037\"\u003eApplication: Residential and light commercial installations\u003c\/li\u003e\n\u003cli data-section-id=\"xjo7ag\" data-start=\"2038\" data-end=\"2083\"\u003eMounting Type: Wall-mounted consumer unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2085\" data-end=\"2088\"\u003e\n\u003ch2 data-section-id=\"s8b5di\" data-start=\"2090\" data-end=\"2132\"\u003eWhy Choose This Dual RCD Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"2134\" data-end=\"2486\"\u003eThis consumer unit stands out for its balance of safety, convenience, and performance. With pre-installed components, it significantly reduces installation time while ensuring compliance with current electrical regulations. The inclusion of an SPD provides essential protection against power surges, helping to extend the lifespan of connected devices.\u003c\/p\u003e\n\u003cp data-start=\"2488\" data-end=\"2759\"\u003eAdditionally, the dual RCD configuration improves reliability by isolating faults to specific circuits, preventing complete system shutdowns. Its compact yet versatile design makes it an ideal choice for electricians seeking a dependable and efficient distribution board.\u003c\/p\u003e\n\u003chr data-start=\"2761\" data-end=\"2764\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2766\" data-end=\"2802\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2804\" data-end=\"2979\"\u003e\u003cstrong data-start=\"2804\" data-end=\"2859\"\u003e1. What is the benefit of a dual RCD consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"2859\" data-end=\"2862\"\u003eA dual RCD unit splits circuits across two RCDs, reducing the risk of total power loss if a fault occurs on one side.\u003c\/p\u003e\n\u003cp data-start=\"2981\" data-end=\"3157\"\u003e\u003cstrong data-start=\"2981\" data-end=\"3031\"\u003e2. Why is an SPD important in a consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"3031\" data-end=\"3034\"\u003eAn SPD protects electrical appliances from voltage spikes caused by lightning or power surges, preventing potential damage.\u003c\/p\u003e\n\u003cp data-start=\"3159\" data-end=\"3327\"\u003e\u003cstrong data-start=\"3159\" data-end=\"3217\"\u003e3. Is this consumer unit suitable for residential use?\u003c\/strong\u003e\u003cbr data-start=\"3217\" data-end=\"3220\"\u003eYes, it is ideal for both residential and light commercial applications due to its versatile configuration.\u003c\/p\u003e\n\u003cp data-start=\"3329\" data-end=\"3514\"\u003e\u003cstrong data-start=\"3329\" data-end=\"3378\"\u003e4. What type of RCD is included in this unit?\u003c\/strong\u003e\u003cbr data-start=\"3378\" data-end=\"3381\"\u003eIt features a 63A Type A RCD, which is suitable for handling modern electrical loads including appliances with electronic components.\u003c\/p\u003e\n\u003cp data-start=\"3516\" data-end=\"3693\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3516\" data-end=\"3553\"\u003e5. Does this unit come pre-wired?\u003c\/strong\u003e\u003cbr data-start=\"3553\" data-end=\"3556\"\u003eIt comes pre-populated with MCBs and components, making installation quicker, though final wiring is required by a qualified electrician.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289356968318,"sku":null,"price":92.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E1406TR-AS-side_1.png?v=1776698808"},{"product_id":"dual-rcd-consumer-unit-with-spd-10-way-18-module-board","title":"Dual RCD Consumer Unit with SPD – 10 Way 18 Module Board","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-92\" data-testid=\"conversation-turn-4\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"12f9ca1f-5ed0-42f1-8ec1-1c12cc7b68d1\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"335\" data-end=\"354\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"356\" data-end=\"798\"\u003eThe E1810TR-AS Dual RCD Consumer Unit is a high-capacity electrical distribution solution designed for modern installations requiring enhanced circuit management and protection. With an 18-module enclosure and 10 usable ways, this fully populated board offers a practical and efficient setup for both residential and light commercial environments. Pre-installed MCBs streamline installation, saving time while ensuring consistent performance.\u003c\/p\u003e\n\u003cp data-start=\"800\" data-end=\"1159\"\u003eThis consumer unit features a 63A Type A RCD combined with an integrated Surge Protection Device (SPD), delivering advanced protection against electrical faults and transient surges. Its versatile breaker configuration (3x6A, 2x16A, 4x32A, 1x40A) supports a wide range of circuits, making it ideal for handling diverse electrical loads safely and efficiently.\u003c\/p\u003e\n\u003chr data-start=\"1161\" data-end=\"1164\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1166\" data-end=\"1181\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1183\" data-end=\"1629\"\u003e\n\u003cli data-section-id=\"1yt9p9b\" data-start=\"1183\" data-end=\"1232\"\u003eFully populated 10 way dual RCD consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"nnl3rk\" data-start=\"1233\" data-end=\"1286\"\u003eSpacious 18 module enclosure for organized wiring\u003c\/li\u003e\n\u003cli data-section-id=\"1hwcu7x\" data-start=\"1287\" data-end=\"1341\"\u003eIntegrated SPD for protection against power surges\u003c\/li\u003e\n\u003cli data-section-id=\"zd233f\" data-start=\"1342\" data-end=\"1400\"\u003e63A Type A RCD for modern electrical safety compliance\u003c\/li\u003e\n\u003cli data-section-id=\"h3wd86\" data-start=\"1401\" data-end=\"1456\"\u003ePre-configured MCBs for quick and easy installation\u003c\/li\u003e\n\u003cli data-section-id=\"lr7yir\" data-start=\"1457\" data-end=\"1518\"\u003eEfficient circuit separation to minimize power disruption\u003c\/li\u003e\n\u003cli data-section-id=\"1gkt1yy\" data-start=\"1519\" data-end=\"1572\"\u003eSuitable for residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"sl4azh\" data-start=\"1573\" data-end=\"1629\"\u003eDurable and compact design for long-term reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1631\" data-end=\"1634\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1636\" data-end=\"1663\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1665\" data-end=\"2025\"\u003e\n\u003cli data-section-id=\"4e4qx5\" data-start=\"1665\" data-end=\"1686\"\u003eModel: E1810TR-AS\u003c\/li\u003e\n\u003cli data-section-id=\"17nvh1x\" data-start=\"1687\" data-end=\"1721\"\u003eNumber of Ways: 10 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"174xttc\" data-start=\"1722\" data-end=\"1760\"\u003eTotal Modules: 18 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"rw4z8m\" data-start=\"1761\" data-end=\"1781\"\u003eRCD Type: Type A\u003c\/li\u003e\n\u003cli data-section-id=\"1jh8x38\" data-start=\"1782\" data-end=\"1801\"\u003eRCD Rating: 63A\u003c\/li\u003e\n\u003cli data-section-id=\"5b6i8c\" data-start=\"1802\" data-end=\"1836\"\u003eSurge Protection: Built-in SPD\u003c\/li\u003e\n\u003cli data-section-id=\"gatpem\" data-start=\"1837\" data-end=\"1914\"\u003eMCB Configuration:\n\u003cul data-start=\"1862\" data-end=\"1914\"\u003e\n\u003cli data-section-id=\"1hrlzjo\" data-start=\"1862\" data-end=\"1872\"\u003e3 x 6A\u003c\/li\u003e\n\u003cli data-section-id=\"c75q78\" data-start=\"1875\" data-end=\"1886\"\u003e2 x 16A\u003c\/li\u003e\n\u003cli data-section-id=\"5ugtpg\" data-start=\"1889\" data-end=\"1900\"\u003e4 x 32A\u003c\/li\u003e\n\u003cli data-section-id=\"4z3zj8\" data-start=\"1903\" data-end=\"1914\"\u003e1 x 40A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"86so9s\" data-start=\"1915\" data-end=\"1975\"\u003eApplication: Domestic and light commercial installations\u003c\/li\u003e\n\u003cli data-section-id=\"13srfmh\" data-start=\"1976\" data-end=\"2025\"\u003eInstallation Type: Wall-mounted consumer unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2027\" data-end=\"2030\"\u003e\n\u003ch2 data-section-id=\"s8b5di\" data-start=\"2032\" data-end=\"2074\"\u003eWhy Choose This Dual RCD Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"2076\" data-end=\"2396\"\u003eChoosing this 10 way dual RCD consumer unit ensures a balance of safety, flexibility, and installation efficiency. The inclusion of a surge protection device helps protect valuable electronics from unexpected voltage spikes, while the dual RCD layout improves system reliability by isolating faults to specific circuits.\u003c\/p\u003e\n\u003cp data-start=\"2398\" data-end=\"2681\"\u003eIts larger capacity makes it ideal for properties with higher electrical demands or future expansion needs. With pre-installed components and a well-structured design, it simplifies installation while maintaining high safety standards, making it a preferred choice for professionals.\u003c\/p\u003e\n\u003chr data-start=\"2683\" data-end=\"2686\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2688\" data-end=\"2724\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2726\" data-end=\"2903\"\u003e\u003cstrong data-start=\"2726\" data-end=\"2778\"\u003e1. What makes a 10 way consumer unit beneficial?\u003c\/strong\u003e\u003cbr data-start=\"2778\" data-end=\"2781\"\u003eIt allows more circuits to be connected, making it suitable for larger homes or properties with higher electrical demands.\u003c\/p\u003e\n\u003cp data-start=\"2905\" data-end=\"3067\"\u003e\u003cstrong data-start=\"2905\" data-end=\"2946\"\u003e2. What does the SPD do in this unit?\u003c\/strong\u003e\u003cbr data-start=\"2946\" data-end=\"2949\"\u003eThe SPD protects connected devices from voltage spikes caused by external factors like lightning or grid fluctuations.\u003c\/p\u003e\n\u003cp data-start=\"3069\" data-end=\"3237\"\u003e\u003cstrong data-start=\"3069\" data-end=\"3130\"\u003e3. Is this consumer unit compliant with modern standards?\u003c\/strong\u003e\u003cbr data-start=\"3130\" data-end=\"3133\"\u003eYes, it includes a Type A RCD and SPD, meeting current safety requirements for electrical installations.\u003c\/p\u003e\n\u003cp data-start=\"3239\" data-end=\"3367\"\u003e\u003cstrong data-start=\"3239\" data-end=\"3292\"\u003e4. Can this unit be used for commercial purposes?\u003c\/strong\u003e\u003cbr data-start=\"3292\" data-end=\"3295\"\u003eIt is suitable for light commercial as well as residential applications.\u003c\/p\u003e\n\u003cp data-start=\"3369\" data-end=\"3513\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3369\" data-end=\"3406\"\u003e5. Does it come ready to install?\u003c\/strong\u003e\u003cbr data-start=\"3406\" data-end=\"3409\"\u003eIt comes pre-populated with MCBs, reducing setup time, but must be installed by a qualified electrician.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289586606462,"sku":null,"price":106.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-33_291e829f-38d2-4bd8-81bb-eda802fa7a74.png?v=1776701714"},{"product_id":"dual-rcd-consumer-unit-with-spd-16-way-24-module-board","title":"Dual RCD Consumer Unit with SPD – 16 Way 24 Module Board","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-93\" data-testid=\"conversation-turn-6\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"5811966c-1df8-4e28-8b6e-abc07927f5eb\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"339\" data-end=\"358\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"360\" data-end=\"815\"\u003eThe E2416TR-AS Dual RCD Consumer Unit is a high-performance electrical distribution board designed for larger installations that demand greater circuit capacity and advanced protection. With a spacious 24-module enclosure and 16 usable ways, this fully populated unit is ideal for managing complex wiring systems in residential and light commercial settings. Its pre-installed MCBs reduce installation time while ensuring an organized and efficient setup.\u003c\/p\u003e\n\u003cp data-start=\"817\" data-end=\"1172\"\u003eEquipped with an 80A Type A RCD and an integrated Surge Protection Device (SPD), this consumer unit delivers superior safety against electrical faults and transient overvoltages. The diverse MCB configuration (6x6A, 1x10A, 2x16A, 5x32A, 2x40A) provides flexibility for a wide range of circuits, making it a dependable choice for modern electrical demands.\u003c\/p\u003e\n\u003chr data-start=\"1174\" data-end=\"1177\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1179\" data-end=\"1194\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1196\" data-end=\"1619\"\u003e\n\u003cli data-section-id=\"w70449\" data-start=\"1196\" data-end=\"1245\"\u003eFully populated 16 way dual RCD consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"96mdhu\" data-start=\"1246\" data-end=\"1297\"\u003eLarge 24 module enclosure for enhanced capacity\u003c\/li\u003e\n\u003cli data-section-id=\"1cnx8pn\" data-start=\"1298\" data-end=\"1352\"\u003eBuilt-in SPD for protection against voltage surges\u003c\/li\u003e\n\u003cli data-section-id=\"cldas1\" data-start=\"1353\" data-end=\"1404\"\u003e80A Type A RCD for high-level electrical safety\u003c\/li\u003e\n\u003cli data-section-id=\"1cglb7l\" data-start=\"1405\" data-end=\"1452\"\u003ePre-configured MCBs for faster installation\u003c\/li\u003e\n\u003cli data-section-id=\"129giz\" data-start=\"1453\" data-end=\"1509\"\u003eEfficient dual RCD design minimizes power disruption\u003c\/li\u003e\n\u003cli data-section-id=\"mkcr11\" data-start=\"1510\" data-end=\"1570\"\u003eSuitable for larger residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"j4xgcr\" data-start=\"1571\" data-end=\"1619\"\u003eRobust construction for long-term durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1621\" data-end=\"1624\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1626\" data-end=\"1653\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1655\" data-end=\"2016\"\u003e\n\u003cli data-section-id=\"10ltl8g\" data-start=\"1655\" data-end=\"1676\"\u003eModel: E2416TR-AS\u003c\/li\u003e\n\u003cli data-section-id=\"igj0yb\" data-start=\"1677\" data-end=\"1711\"\u003eNumber of Ways: 16 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1utmhxb\" data-start=\"1712\" data-end=\"1750\"\u003eTotal Modules: 24 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"rw4z8m\" data-start=\"1751\" data-end=\"1771\"\u003eRCD Type: Type A\u003c\/li\u003e\n\u003cli data-section-id=\"1jioko9\" data-start=\"1772\" data-end=\"1791\"\u003eRCD Rating: 80A\u003c\/li\u003e\n\u003cli data-section-id=\"181dxef\" data-start=\"1792\" data-end=\"1828\"\u003eSurge Protection: Integrated SPD\u003c\/li\u003e\n\u003cli data-section-id=\"nu0247\" data-start=\"1829\" data-end=\"1920\"\u003eMCB Configuration:\n\u003cul data-start=\"1854\" data-end=\"1920\"\u003e\n\u003cli data-section-id=\"1jxwdqp\" data-start=\"1854\" data-end=\"1864\"\u003e6 x 6A\u003c\/li\u003e\n\u003cli data-section-id=\"4wya75\" data-start=\"1867\" data-end=\"1878\"\u003e1 x 10A\u003c\/li\u003e\n\u003cli data-section-id=\"c75q78\" data-start=\"1881\" data-end=\"1892\"\u003e2 x 16A\u003c\/li\u003e\n\u003cli data-section-id=\"1r7hazp\" data-start=\"1895\" data-end=\"1906\"\u003e5 x 32A\u003c\/li\u003e\n\u003cli data-section-id=\"caiucn\" data-start=\"1909\" data-end=\"1920\"\u003e2 x 40A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v3qqkc\" data-start=\"1921\" data-end=\"1984\"\u003eApplication: Residential and light commercial installations\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1985\" data-end=\"2016\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2018\" data-end=\"2021\"\u003e\n\u003ch2 data-section-id=\"s8b5di\" data-start=\"2023\" data-end=\"2065\"\u003eWhy Choose This Dual RCD Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"2067\" data-end=\"2367\"\u003eThis 16 way dual RCD consumer unit is an excellent choice for installations requiring higher capacity and enhanced safety. The inclusion of an 80A Type A RCD ensures reliable protection for modern electrical loads, while the integrated SPD safeguards sensitive equipment from unexpected power surges.\u003c\/p\u003e\n\u003cp data-start=\"2369\" data-end=\"2641\"\u003eIts generous number of ways allows for future expansion, making it a future-proof investment. Combined with a well-balanced MCB configuration and pre-installed components, it simplifies installation while delivering dependable performance for demanding electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"2643\" data-end=\"2646\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2648\" data-end=\"2684\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2686\" data-end=\"2873\"\u003e\u003cstrong data-start=\"2686\" data-end=\"2758\"\u003e1. What type of installations is this consumer unit best suited for?\u003c\/strong\u003e\u003cbr data-start=\"2758\" data-end=\"2761\"\u003eIt is ideal for larger homes and light commercial properties that require multiple circuits and higher capacity.\u003c\/p\u003e\n\u003cp data-start=\"2875\" data-end=\"3032\"\u003e\u003cstrong data-start=\"2875\" data-end=\"2932\"\u003e2. Why does this unit have an 80A RCD instead of 63A?\u003c\/strong\u003e\u003cbr data-start=\"2932\" data-end=\"2935\"\u003eAn 80A RCD supports higher electrical loads, making it suitable for more demanding installations.\u003c\/p\u003e\n\u003cp data-start=\"3034\" data-end=\"3196\"\u003e\u003cstrong data-start=\"3034\" data-end=\"3078\"\u003e3. What protection does the SPD provide?\u003c\/strong\u003e\u003cbr data-start=\"3078\" data-end=\"3081\"\u003eThe SPD protects against voltage spikes caused by lightning or power fluctuations, preventing damage to appliances.\u003c\/p\u003e\n\u003cp data-start=\"3198\" data-end=\"3336\"\u003e\u003cstrong data-start=\"3198\" data-end=\"3244\"\u003e4. Can additional circuits be added later?\u003c\/strong\u003e\u003cbr data-start=\"3244\" data-end=\"3247\"\u003eYes, the 16 way design allows flexibility for adding or modifying circuits in the future.\u003c\/p\u003e\n\u003cp data-start=\"3338\" data-end=\"3492\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3338\" data-end=\"3383\"\u003e5. Is professional installation required?\u003c\/strong\u003e\u003cbr data-start=\"3383\" data-end=\"3386\"\u003eYes, installation should always be carried out by a qualified electrician to ensure safety and compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289604301182,"sku":null,"price":122.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E2416TR100-AS-side.png?v=1776702154"},{"product_id":"dual-rcd-consumer-unit-14-module-8-way-distribution-board","title":"Dual RCD Consumer Unit – 14 Module 8 Way Distribution Board","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-94\" data-testid=\"conversation-turn-8\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"bc9da731-803a-4b61-944b-7d0b1eba9c62\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"343\" data-end=\"362\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"364\" data-end=\"814\"\u003eThe E1408TR-A Dual RCD Consumer Unit is a practical and efficient electrical distribution solution designed for residential and light commercial applications. Featuring a compact 14-module enclosure with 8 usable ways, this unit offers a well-balanced configuration for managing multiple circuits while maintaining a neat and organized setup. Supplied with pre-installed MCBs, it helps reduce installation time and ensures consistency in performance.\u003c\/p\u003e\n\u003cp data-start=\"816\" data-end=\"1160\"\u003eBuilt with a 63A Type A RCD, this consumer unit provides dependable protection against electrical faults, making it suitable for modern electrical systems. Its carefully selected MCB configuration (3x6A, 1x16A, 3x32A, 1x40A) allows for flexible circuit distribution, supporting a variety of applications while maintaining safety and efficiency.\u003c\/p\u003e\n\u003chr data-start=\"1162\" data-end=\"1165\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1167\" data-end=\"1182\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1184\" data-end=\"1617\"\u003e\n\u003cli data-section-id=\"72rtzg\" data-start=\"1184\" data-end=\"1249\"\u003e8 way dual RCD consumer unit for efficient circuit management\u003c\/li\u003e\n\u003cli data-section-id=\"15shf8g\" data-start=\"1250\" data-end=\"1311\"\u003eCompact 14 module enclosure for space-saving installation\u003c\/li\u003e\n\u003cli data-section-id=\"5dgucq\" data-start=\"1312\" data-end=\"1360\"\u003e63A Type A RCD for reliable fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"1x7s8j5\" data-start=\"1361\" data-end=\"1414\"\u003eSupplied with pre-configured MCBs for convenience\u003c\/li\u003e\n\u003cli data-section-id=\"ljhh3y\" data-start=\"1415\" data-end=\"1473\"\u003eBalanced circuit distribution for improved performance\u003c\/li\u003e\n\u003cli data-section-id=\"dt94t6\" data-start=\"1474\" data-end=\"1509\"\u003eDurable and robust construction\u003c\/li\u003e\n\u003cli data-section-id=\"c3yi6m\" data-start=\"1510\" data-end=\"1560\"\u003eIdeal for residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"396xmi\" data-start=\"1561\" data-end=\"1617\"\u003eSimplifies installation with ready-to-fit components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1619\" data-end=\"1622\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1624\" data-end=\"1651\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1653\" data-end=\"1958\"\u003e\n\u003cli data-section-id=\"14v0fi7\" data-start=\"1653\" data-end=\"1673\"\u003eModel: E1408TR-A\u003c\/li\u003e\n\u003cli data-section-id=\"1xf08zw\" data-start=\"1674\" data-end=\"1707\"\u003eNumber of Ways: 8 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"12ud1h8\" data-start=\"1708\" data-end=\"1746\"\u003eTotal Modules: 14 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"rw4z8m\" data-start=\"1747\" data-end=\"1767\"\u003eRCD Type: Type A\u003c\/li\u003e\n\u003cli data-section-id=\"1jh8x38\" data-start=\"1768\" data-end=\"1787\"\u003eRCD Rating: 63A\u003c\/li\u003e\n\u003cli data-section-id=\"op51ju\" data-start=\"1788\" data-end=\"1865\"\u003eMCB Configuration:\n\u003cul data-start=\"1813\" data-end=\"1865\"\u003e\n\u003cli data-section-id=\"1hrlzjo\" data-start=\"1813\" data-end=\"1823\"\u003e3 x 6A\u003c\/li\u003e\n\u003cli data-section-id=\"4x5w4n\" data-start=\"1826\" data-end=\"1837\"\u003e1 x 16A\u003c\/li\u003e\n\u003cli data-section-id=\"1xirdcz\" data-start=\"1840\" data-end=\"1851\"\u003e3 x 32A\u003c\/li\u003e\n\u003cli data-section-id=\"4z3zj8\" data-start=\"1854\" data-end=\"1865\"\u003e1 x 40A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"86so9s\" data-start=\"1866\" data-end=\"1926\"\u003eApplication: Domestic and light commercial installations\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1927\" data-end=\"1958\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1960\" data-end=\"1963\"\u003e\n\u003ch2 data-section-id=\"s8b5di\" data-start=\"1965\" data-end=\"2007\"\u003eWhy Choose This Dual RCD Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"2009\" data-end=\"2294\"\u003eThis dual RCD consumer unit is an excellent choice for those seeking a reliable and straightforward electrical distribution system without the need for surge protection. Its dual RCD design enhances safety by splitting circuits, reducing the risk of a full power outage during a fault.\u003c\/p\u003e\n\u003cp data-start=\"2296\" data-end=\"2551\"\u003eWith pre-installed MCBs and a compact design, it offers both convenience and efficiency for installers. The flexible circuit configuration ensures compatibility with a wide range of electrical needs, making it a dependable option for modern installations.\u003c\/p\u003e\n\u003chr data-start=\"2553\" data-end=\"2556\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2558\" data-end=\"2594\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2596\" data-end=\"2771\"\u003e\u003cstrong data-start=\"2596\" data-end=\"2652\"\u003e1. Does this consumer unit include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2652\" data-end=\"2655\"\u003eNo, this model does not include an SPD, making it suitable for installations where surge protection is not required.\u003c\/p\u003e\n\u003cp data-start=\"2773\" data-end=\"2938\"\u003e\u003cstrong data-start=\"2773\" data-end=\"2820\"\u003e2. What is the benefit of a dual RCD setup?\u003c\/strong\u003e\u003cbr data-start=\"2820\" data-end=\"2823\"\u003eA dual RCD setup divides circuits across two RCDs, helping maintain power to unaffected circuits if a fault occurs.\u003c\/p\u003e\n\u003cp data-start=\"2940\" data-end=\"3079\"\u003e\u003cstrong data-start=\"2940\" data-end=\"2982\"\u003e3. Is this unit suitable for home use?\u003c\/strong\u003e\u003cbr data-start=\"2982\" data-end=\"2985\"\u003eYes, it is ideal for residential properties and can also be used in light commercial settings.\u003c\/p\u003e\n\u003cp data-start=\"3081\" data-end=\"3197\"\u003e\u003cstrong data-start=\"3081\" data-end=\"3124\"\u003e4. Are the MCBs included with the unit?\u003c\/strong\u003e\u003cbr data-start=\"3124\" data-end=\"3127\"\u003eYes, the unit comes fully populated with the listed MCB configuration.\u003c\/p\u003e\n\u003cp data-start=\"3199\" data-end=\"3353\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3199\" data-end=\"3253\"\u003e5. Can this unit support future circuit expansion?\u003c\/strong\u003e\u003cbr data-start=\"3253\" data-end=\"3256\"\u003eWith 8 usable ways, it allows for moderate flexibility in adding or modifying circuits as needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289627468158,"sku":null,"price":84.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-34.png?v=1776702532"},{"product_id":"dual-rcd-consumer-unit-18-module-12-way-distribution-board","title":"Dual RCD Consumer Unit – 18 Module 12 Way Distribution Board","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-95\" data-testid=\"conversation-turn-10\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"0e64ebc6-12f1-41a8-8c22-037a5a720778\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"337\" data-end=\"356\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"358\" data-end=\"806\"\u003eThe E1812TR-A Dual RCD Consumer Unit is a versatile and high-capacity solution designed for modern electrical distribution needs. Featuring an 18-module enclosure with 12 usable ways, this unit provides ample space for managing multiple circuits efficiently. It comes fully equipped with pre-installed MCBs, allowing for quicker installation and a more organized wiring setup, making it ideal for both residential and light commercial environments.\u003c\/p\u003e\n\u003cp data-start=\"808\" data-end=\"1142\"\u003eEngineered with a 63A Type A RCD, this consumer unit ensures reliable protection against electrical faults while supporting contemporary electrical loads. The balanced MCB configuration (3x6A, 3x16A, 5x32A, 1x40A) offers flexibility for a wide range of applications, ensuring efficient circuit distribution and dependable performance.\u003c\/p\u003e\n\u003chr data-start=\"1144\" data-end=\"1147\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1149\" data-end=\"1164\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1166\" data-end=\"1594\"\u003e\n\u003cli data-section-id=\"13f2rym\" data-start=\"1166\" data-end=\"1229\"\u003e12 way dual RCD consumer unit for expanded circuit capacity\u003c\/li\u003e\n\u003cli data-section-id=\"1725kd9\" data-start=\"1230\" data-end=\"1281\"\u003e18 module enclosure for better space management\u003c\/li\u003e\n\u003cli data-section-id=\"o6sf53\" data-start=\"1282\" data-end=\"1331\"\u003e63A Type A RCD for enhanced electrical safety\u003c\/li\u003e\n\u003cli data-section-id=\"uoujof\" data-start=\"1332\" data-end=\"1390\"\u003ePre-populated with MCBs for easy and fast installation\u003c\/li\u003e\n\u003cli data-section-id=\"87q8e3\" data-start=\"1391\" data-end=\"1446\"\u003eBalanced circuit allocation for improved efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"1s3haq8\" data-start=\"1447\" data-end=\"1509\"\u003eSuitable for residential and light commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"14uh0ov\" data-start=\"1510\" data-end=\"1540\"\u003eDurable and compact design\u003c\/li\u003e\n\u003cli data-section-id=\"h8s9w6\" data-start=\"1541\" data-end=\"1594\"\u003eHelps reduce downtime with dual RCD configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1596\" data-end=\"1599\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1601\" data-end=\"1628\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1630\" data-end=\"1926\"\u003e\n\u003cli data-section-id=\"doteu0\" data-start=\"1630\" data-end=\"1650\"\u003eModel: E1812TR-A\u003c\/li\u003e\n\u003cli data-section-id=\"1axrd7b\" data-start=\"1651\" data-end=\"1685\"\u003eNumber of Ways: 12 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"174xttc\" data-start=\"1686\" data-end=\"1724\"\u003eTotal Modules: 18 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"rw4z8m\" data-start=\"1725\" data-end=\"1745\"\u003eRCD Type: Type A\u003c\/li\u003e\n\u003cli data-section-id=\"1jh8x38\" data-start=\"1746\" data-end=\"1765\"\u003eRCD Rating: 63A\u003c\/li\u003e\n\u003cli data-section-id=\"3arony\" data-start=\"1766\" data-end=\"1843\"\u003eMCB Configuration:\n\u003cul data-start=\"1791\" data-end=\"1843\"\u003e\n\u003cli data-section-id=\"1hrlzjo\" data-start=\"1791\" data-end=\"1801\"\u003e3 x 6A\u003c\/li\u003e\n\u003cli data-section-id=\"1xk67hh\" data-start=\"1804\" data-end=\"1815\"\u003e3 x 16A\u003c\/li\u003e\n\u003cli data-section-id=\"1r7hazp\" data-start=\"1818\" data-end=\"1829\"\u003e5 x 32A\u003c\/li\u003e\n\u003cli data-section-id=\"4z3zj8\" data-start=\"1832\" data-end=\"1843\"\u003e1 x 40A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g8pbt8\" data-start=\"1844\" data-end=\"1894\"\u003eApplication: Domestic and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1895\" data-end=\"1926\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1928\" data-end=\"1931\"\u003e\n\u003ch2 data-section-id=\"s8b5di\" data-start=\"1933\" data-end=\"1975\"\u003eWhy Choose This Dual RCD Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"1977\" data-end=\"2232\"\u003eThis 12 way dual RCD consumer unit offers a strong combination of capacity, safety, and installation convenience. Its dual RCD design enhances reliability by isolating faults to specific circuit groups, ensuring that not all power is lost during an issue.\u003c\/p\u003e\n\u003cp data-start=\"2234\" data-end=\"2513\"\u003eThe pre-installed MCBs and well-planned configuration make it easier for electricians to install and manage circuits efficiently. With its robust build and flexible layout, it is an ideal choice for properties requiring a dependable and scalable electrical distribution solution.\u003c\/p\u003e\n\u003chr data-start=\"2515\" data-end=\"2518\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2520\" data-end=\"2556\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2558\" data-end=\"2720\"\u003e\u003cstrong data-start=\"2558\" data-end=\"2624\"\u003e1. What type of properties is this consumer unit suitable for?\u003c\/strong\u003e\u003cbr data-start=\"2624\" data-end=\"2627\"\u003eIt is suitable for medium to large residential properties and light commercial installations.\u003c\/p\u003e\n\u003cp data-start=\"2722\" data-end=\"2870\"\u003e\u003cstrong data-start=\"2722\" data-end=\"2769\"\u003e2. Does this unit include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2769\" data-end=\"2772\"\u003eNo, this model does not include an SPD, making it suitable where surge protection is not required.\u003c\/p\u003e\n\u003cp data-start=\"2872\" data-end=\"3023\"\u003e\u003cstrong data-start=\"2872\" data-end=\"2919\"\u003e3. What is the advantage of having 12 ways?\u003c\/strong\u003e\u003cbr data-start=\"2919\" data-end=\"2922\"\u003eIt allows more circuits to be connected, providing greater flexibility for complex electrical setups.\u003c\/p\u003e\n\u003cp data-start=\"3025\" data-end=\"3151\"\u003e\u003cstrong data-start=\"3025\" data-end=\"3065\"\u003e4. Are MCBs included with this unit?\u003c\/strong\u003e\u003cbr data-start=\"3065\" data-end=\"3068\"\u003eYes, it comes fully populated with the specified MCB configuration for convenience.\u003c\/p\u003e\n\u003cp data-start=\"3153\" data-end=\"3308\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3153\" data-end=\"3199\"\u003e5. Is professional installation necessary?\u003c\/strong\u003e\u003cbr data-start=\"3199\" data-end=\"3202\"\u003eYes, installation should always be carried out by a qualified electrician to ensure safety and compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289645916542,"sku":null,"price":99.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E1812TR-A-side.png?v=1776702759"},{"product_id":"dual-rcd-consumer-unit-24-module-18-way-distribution-board","title":"Dual RCD Consumer Unit – 24 Module 18 Way Distribution Board","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-96\" data-testid=\"conversation-turn-12\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"8adc302a-9e18-4e3c-8026-eff7ae75fdd8\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"333\" data-end=\"352\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"354\" data-end=\"760\"\u003eThe E2418TR-A Dual RCD Consumer Unit is a high-capacity electrical distribution board designed for large residential and light commercial installations. With a spacious 24-module enclosure and 18 usable ways, it offers exceptional flexibility for managing multiple circuits efficiently. Supplied with pre-installed MCBs, this unit simplifies installation while ensuring a clean and organized wiring layout.\u003c\/p\u003e\n\u003cp data-start=\"762\" data-end=\"1100\"\u003eBuilt with a 63A Type A RCD, this consumer unit provides dependable protection against electrical faults, making it suitable for modern electrical systems. Its comprehensive MCB configuration (6x6A, 4x16A, 6x32A, 2x40A) supports a wide variety of circuits, ensuring reliable and efficient power distribution across demanding applications.\u003c\/p\u003e\n\u003chr data-start=\"1102\" data-end=\"1105\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1107\" data-end=\"1122\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1124\" data-end=\"1587\"\u003e\n\u003cli data-section-id=\"1vy2ezv\" data-start=\"1124\" data-end=\"1186\"\u003e18 way dual RCD consumer unit for maximum circuit capacity\u003c\/li\u003e\n\u003cli data-section-id=\"15nrg5f\" data-start=\"1187\" data-end=\"1237\"\u003eLarge 24 module enclosure for organized wiring\u003c\/li\u003e\n\u003cli data-section-id=\"5dgucq\" data-start=\"1238\" data-end=\"1286\"\u003e63A Type A RCD for reliable fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"h3wd86\" data-start=\"1287\" data-end=\"1342\"\u003ePre-configured MCBs for quick and easy installation\u003c\/li\u003e\n\u003cli data-section-id=\"1nmaifw\" data-start=\"1343\" data-end=\"1403\"\u003eDual RCD design minimizes total power loss during faults\u003c\/li\u003e\n\u003cli data-section-id=\"2xifqj\" data-start=\"1404\" data-end=\"1473\"\u003eSuitable for large residential and light commercial installations\u003c\/li\u003e\n\u003cli data-section-id=\"1q9dp3p\" data-start=\"1474\" data-end=\"1527\"\u003eStrong and durable construction for long-term use\u003c\/li\u003e\n\u003cli data-section-id=\"11motzq\" data-start=\"1528\" data-end=\"1587\"\u003eFlexible circuit configuration for diverse applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1589\" data-end=\"1592\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1594\" data-end=\"1621\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1623\" data-end=\"1922\"\u003e\n\u003cli data-section-id=\"pa4xfh\" data-start=\"1623\" data-end=\"1643\"\u003eModel: E2418TR-A\u003c\/li\u003e\n\u003cli data-section-id=\"v19xjx\" data-start=\"1644\" data-end=\"1678\"\u003eNumber of Ways: 18 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1utmhxb\" data-start=\"1679\" data-end=\"1717\"\u003eTotal Modules: 24 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"rw4z8m\" data-start=\"1718\" data-end=\"1738\"\u003eRCD Type: Type A\u003c\/li\u003e\n\u003cli data-section-id=\"1jh8x38\" data-start=\"1739\" data-end=\"1758\"\u003eRCD Rating: 63A\u003c\/li\u003e\n\u003cli data-section-id=\"sqojb0\" data-start=\"1759\" data-end=\"1836\"\u003eMCB Configuration:\n\u003cul data-start=\"1784\" data-end=\"1836\"\u003e\n\u003cli data-section-id=\"1jxwdqp\" data-start=\"1784\" data-end=\"1794\"\u003e6 x 6A\u003c\/li\u003e\n\u003cli data-section-id=\"5t1zky\" data-start=\"1797\" data-end=\"1808\"\u003e4 x 16A\u003c\/li\u003e\n\u003cli data-section-id=\"1yetmna\" data-start=\"1811\" data-end=\"1822\"\u003e6 x 32A\u003c\/li\u003e\n\u003cli data-section-id=\"caiucn\" data-start=\"1825\" data-end=\"1836\"\u003e2 x 40A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4foi6o\" data-start=\"1837\" data-end=\"1890\"\u003eApplication: Residential and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1891\" data-end=\"1922\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1924\" data-end=\"1927\"\u003e\n\u003ch2 data-section-id=\"s8b5di\" data-start=\"1929\" data-end=\"1971\"\u003eWhy Choose This Dual RCD Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"1973\" data-end=\"2283\"\u003eThis 18 way dual RCD consumer unit is designed for installations requiring high circuit capacity and dependable performance. Its dual RCD configuration enhances safety by isolating faults, ensuring that unaffected circuits remain operational. This reduces inconvenience and improves overall system reliability.\u003c\/p\u003e\n\u003cp data-start=\"2285\" data-end=\"2573\"\u003eWith a large number of ways and a balanced MCB setup, it is ideal for properties with extensive electrical demands or future expansion plans. The pre-installed components make installation more efficient, while the robust design ensures long-lasting performance in demanding environments.\u003c\/p\u003e\n\u003chr data-start=\"2575\" data-end=\"2578\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2580\" data-end=\"2616\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2618\" data-end=\"2799\"\u003e\u003cstrong data-start=\"2618\" data-end=\"2682\"\u003e1. What type of installation is this consumer unit best for?\u003c\/strong\u003e\u003cbr data-start=\"2682\" data-end=\"2685\"\u003eIt is ideal for large homes, multi-unit properties, and light commercial environments requiring multiple circuits.\u003c\/p\u003e\n\u003cp data-start=\"2801\" data-end=\"2949\"\u003e\u003cstrong data-start=\"2801\" data-end=\"2848\"\u003e2. Does this unit include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2848\" data-end=\"2851\"\u003eNo, this model does not include an SPD, making it suitable where surge protection is not required.\u003c\/p\u003e\n\u003cp data-start=\"2951\" data-end=\"3095\"\u003e\u003cstrong data-start=\"2951\" data-end=\"2996\"\u003e3. What is the benefit of 18 usable ways?\u003c\/strong\u003e\u003cbr data-start=\"2996\" data-end=\"2999\"\u003eIt allows for extensive circuit management and flexibility, especially in complex installations.\u003c\/p\u003e\n\u003cp data-start=\"3097\" data-end=\"3210\"\u003e\u003cstrong data-start=\"3097\" data-end=\"3134\"\u003e4. Are MCBs included in the unit?\u003c\/strong\u003e\u003cbr data-start=\"3134\" data-end=\"3137\"\u003eYes, the unit comes fully populated with the specified MCB configuration.\u003c\/p\u003e\n\u003cp data-start=\"3212\" data-end=\"3362\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3212\" data-end=\"3262\"\u003e5. Should this be installed by a professional?\u003c\/strong\u003e\u003cbr data-start=\"3262\" data-end=\"3265\"\u003eYes, installation must be carried out by a qualified electrician to ensure safety and compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289684386174,"sku":null,"price":115.64,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/E2418TR-A-side.png?v=1776703116"},{"product_id":"5-module-garage-consumer-unit-lockable-metal-distribution-board","title":"5 Module Garage Consumer Unit – Lockable Metal Distribution Board","description":"\u003ch2 data-section-id=\"1p927wt\" data-start=\"346\" data-end=\"365\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"367\" data-end=\"784\"\u003eThe EMGU05 Garage Consumer Unit is a compact and durable electrical distribution solution designed specifically for garages, workshops, and small outbuildings. With a 5-module enclosure and 5 usable ways, this unit provides a practical setup for managing essential circuits in confined spaces. Its metal construction ensures enhanced protection and longevity, making it ideal for environments where durability is key.\u003c\/p\u003e\n\u003cp data-start=\"786\" data-end=\"1110\"\u003eThis unit comes complete with earth and neutral bars, allowing for straightforward installation and efficient wiring. The lockable design adds an extra layer of security, preventing unauthorized access and ensuring safe operation. Its simple yet robust configuration makes it a reliable choice for smaller electrical setups.\u003c\/p\u003e\n\u003chr data-start=\"1112\" data-end=\"1115\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1117\" data-end=\"1132\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1134\" data-end=\"1487\"\u003e\n\u003cli data-section-id=\"1ga1n1r\" data-start=\"1134\" data-end=\"1175\"\u003eCompact 5 module garage consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"1op65em\" data-start=\"1176\" data-end=\"1227\"\u003e5 usable ways for essential circuit connections\u003c\/li\u003e\n\u003cli data-section-id=\"ajb67j\" data-start=\"1228\" data-end=\"1275\"\u003eLockable metal enclosure for added security\u003c\/li\u003e\n\u003cli data-section-id=\"80q1su\" data-start=\"1276\" data-end=\"1316\"\u003eSupplied with earth and neutral bars\u003c\/li\u003e\n\u003cli data-section-id=\"v3slj1\" data-start=\"1317\" data-end=\"1369\"\u003eDurable construction for garage and workshop use\u003c\/li\u003e\n\u003cli data-section-id=\"12nma14\" data-start=\"1370\" data-end=\"1414\"\u003eIdeal for small electrical installations\u003c\/li\u003e\n\u003cli data-section-id=\"1l2bolq\" data-start=\"1415\" data-end=\"1447\"\u003eEasy to install and maintain\u003c\/li\u003e\n\u003cli data-section-id=\"6u1v1q\" data-start=\"1448\" data-end=\"1487\"\u003eSpace-saving design for tight areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1489\" data-end=\"1492\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1494\" data-end=\"1521\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1523\" data-end=\"1792\"\u003e\n\u003cli data-section-id=\"8ambqa\" data-start=\"1523\" data-end=\"1540\"\u003eModel: EMGU05\u003c\/li\u003e\n\u003cli data-section-id=\"lp4z29\" data-start=\"1541\" data-end=\"1574\"\u003eNumber of Ways: 5 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1v8jz61\" data-start=\"1575\" data-end=\"1614\"\u003eModule Capacity: 5 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"15t787m\" data-start=\"1615\" data-end=\"1644\"\u003eMaterial: Metal enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1qhqc0s\" data-start=\"1645\" data-end=\"1662\"\u003eLockable: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1xadrsw\" data-start=\"1663\" data-end=\"1710\"\u003eIncluded Components: Earth and neutral bars\u003c\/li\u003e\n\u003cli data-section-id=\"135p375\" data-start=\"1711\" data-end=\"1760\"\u003eApplication: Garages, workshops, outbuildings\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1761\" data-end=\"1792\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1794\" data-end=\"1797\"\u003e\n\u003ch2 data-section-id=\"y21iko\" data-start=\"1799\" data-end=\"1839\"\u003eWhy Choose This Garage Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"1841\" data-end=\"2123\"\u003eThis garage consumer unit is an excellent choice for those needing a compact yet secure electrical distribution solution. Its lockable metal enclosure provides added safety, making it suitable for environments where protection against accidental or unauthorized access is important.\u003c\/p\u003e\n\u003cp data-start=\"2125\" data-end=\"2370\"\u003eDesigned for simplicity and efficiency, it offers just the right capacity for smaller installations without unnecessary complexity. Its sturdy build and practical features make it a dependable option for garages, sheds, and other utility spaces.\u003c\/p\u003e\n\u003chr data-start=\"2372\" data-end=\"2375\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2377\" data-end=\"2413\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2415\" data-end=\"2549\"\u003e\u003cstrong data-start=\"2415\" data-end=\"2456\"\u003e1. What is this garage unit used for?\u003c\/strong\u003e\u003cbr data-start=\"2456\" data-end=\"2459\"\u003eIt is used to distribute electricity safely in garages, workshops, and small outbuildings.\u003c\/p\u003e\n\u003cp data-start=\"2551\" data-end=\"2684\"\u003e\u003cstrong data-start=\"2551\" data-end=\"2600\"\u003e2. Does this unit come with circuit breakers?\u003c\/strong\u003e\u003cbr data-start=\"2600\" data-end=\"2603\"\u003eNo, it is an empty unit designed to be fitted with appropriate devices as needed.\u003c\/p\u003e\n\u003cp data-start=\"2686\" data-end=\"2794\"\u003e\u003cstrong data-start=\"2686\" data-end=\"2717\"\u003e3. Is the enclosure secure?\u003c\/strong\u003e\u003cbr data-start=\"2717\" data-end=\"2720\"\u003eYes, it features a lockable metal enclosure for added safety and security.\u003c\/p\u003e\n\u003cp data-start=\"2796\" data-end=\"2912\"\u003e\u003cstrong data-start=\"2796\" data-end=\"2834\"\u003e4. Can this unit be used outdoors?\u003c\/strong\u003e\u003cbr data-start=\"2834\" data-end=\"2837\"\u003eIt is suitable for indoor or sheltered environments like garages and sheds.\u003c\/p\u003e\n\u003cp data-start=\"2914\" data-end=\"3026\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2914\" data-end=\"2943\"\u003e5. Is it easy to install?\u003c\/strong\u003e\u003cbr data-start=\"2943\" data-end=\"2946\"\u003eYes, it is designed for straightforward installation by a qualified electrician.\u003c\/p\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289699754366,"sku":null,"price":14.56,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EMGU05-side.png?v=1776703498"},{"product_id":"garage-consumer-unit-with-rcd-5-module-lockable-board","title":"Garage Consumer Unit with RCD – 5 Module Lockable Board","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-98\" data-testid=\"conversation-turn-16\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"41aa9175-6000-45d2-9735-a1e5a5f1ee1d\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"332\" data-end=\"351\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"353\" data-end=\"781\"\u003eThe EMGU63616 Garage Consumer Unit is a compact and efficient electrical distribution solution designed for garages, sheds, and small workshop environments. Featuring a 5-module metal enclosure with 5 usable ways, this unit is pre-configured with essential protective devices, making it ideal for quick and hassle-free installation. Its sturdy construction ensures durability while maintaining a neat and organized wiring setup.\u003c\/p\u003e\n\u003cp data-start=\"783\" data-end=\"1153\"\u003eEquipped with a 63A 30mA RCD incomer along with 6A and 16A MCBs, this garage unit provides reliable protection against electrical faults and overloads. The inclusion of earth and neutral bars simplifies wiring, while the lockable enclosure enhances safety by restricting unauthorized access. It is a practical choice for managing smaller electrical circuits efficiently.\u003c\/p\u003e\n\u003chr data-start=\"1155\" data-end=\"1158\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1160\" data-end=\"1175\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1177\" data-end=\"1529\"\u003e\n\u003cli data-section-id=\"1ga1n1r\" data-start=\"1177\" data-end=\"1218\"\u003eCompact 5 module garage consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"no7d65\" data-start=\"1219\" data-end=\"1257\"\u003ePre-installed 63A 30mA RCD incomer\u003c\/li\u003e\n\u003cli data-section-id=\"4xxtmx\" data-start=\"1258\" data-end=\"1309\"\u003eIncludes 6A and 16A MCBs for circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"2pbbnp\" data-start=\"1310\" data-end=\"1355\"\u003eLockable metal enclosure for added safety\u003c\/li\u003e\n\u003cli data-section-id=\"80q1su\" data-start=\"1356\" data-end=\"1396\"\u003eSupplied with earth and neutral bars\u003c\/li\u003e\n\u003cli data-section-id=\"xjrdk6\" data-start=\"1397\" data-end=\"1440\"\u003eIdeal for garages, sheds, and workshops\u003c\/li\u003e\n\u003cli data-section-id=\"dt94t6\" data-start=\"1441\" data-end=\"1476\"\u003eDurable and robust construction\u003c\/li\u003e\n\u003cli data-section-id=\"1dcuwjm\" data-start=\"1477\" data-end=\"1529\"\u003eEasy installation with pre-configured components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1531\" data-end=\"1534\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1536\" data-end=\"1563\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1565\" data-end=\"1943\"\u003e\n\u003cli data-section-id=\"1y15d0z\" data-start=\"1565\" data-end=\"1585\"\u003eModel: EMGU63616\u003c\/li\u003e\n\u003cli data-section-id=\"lp4z29\" data-start=\"1586\" data-end=\"1619\"\u003eNumber of Ways: 5 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1v8jz61\" data-start=\"1620\" data-end=\"1659\"\u003eModule Capacity: 5 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1jh8x38\" data-start=\"1660\" data-end=\"1679\"\u003eRCD Rating: 63A\u003c\/li\u003e\n\u003cli data-section-id=\"orxwn9\" data-start=\"1680\" data-end=\"1705\"\u003eRCD Sensitivity: 30mA\u003c\/li\u003e\n\u003cli data-section-id=\"15oet27\" data-start=\"1706\" data-end=\"1755\"\u003eMCB Configuration:\n\u003cul data-start=\"1731\" data-end=\"1755\"\u003e\n\u003cli data-section-id=\"1sq6vee\" data-start=\"1731\" data-end=\"1741\"\u003e1 x 6A\u003c\/li\u003e\n\u003cli data-section-id=\"4x5w4n\" data-start=\"1744\" data-end=\"1755\"\u003e1 x 16A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15t787m\" data-start=\"1756\" data-end=\"1785\"\u003eMaterial: Metal enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1qhqc0s\" data-start=\"1786\" data-end=\"1803\"\u003eLockable: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1xadrsw\" data-start=\"1804\" data-end=\"1851\"\u003eIncluded Components: Earth and neutral bars\u003c\/li\u003e\n\u003cli data-section-id=\"xpatbw\" data-start=\"1852\" data-end=\"1911\"\u003eApplication: Garage and small outbuilding installations\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1912\" data-end=\"1943\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1945\" data-end=\"1948\"\u003e\n\u003ch2 data-section-id=\"y21iko\" data-start=\"1950\" data-end=\"1990\"\u003eWhy Choose This Garage Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"1992\" data-end=\"2315\"\u003eThis garage consumer unit offers a perfect balance of safety, convenience, and compact design. With a pre-installed RCD incomer and MCBs, it significantly reduces installation time while ensuring reliable protection for connected circuits. The 30mA RCD enhances user safety by quickly disconnecting power in case of faults.\u003c\/p\u003e\n\u003cp data-start=\"2317\" data-end=\"2585\"\u003eIts lockable metal enclosure adds an extra layer of security, making it ideal for environments where safety is essential. Designed for smaller electrical setups, it provides an efficient and dependable solution for managing power distribution in garages and workshops.\u003c\/p\u003e\n\u003chr data-start=\"2587\" data-end=\"2590\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2592\" data-end=\"2628\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2630\" data-end=\"2773\"\u003e\u003cstrong data-start=\"2630\" data-end=\"2679\"\u003e1. What protection does the 30mA RCD provide?\u003c\/strong\u003e\u003cbr data-start=\"2679\" data-end=\"2682\"\u003eIt protects against electric shock by quickly disconnecting power when a fault is detected.\u003c\/p\u003e\n\u003cp data-start=\"2775\" data-end=\"2907\"\u003e\u003cstrong data-start=\"2775\" data-end=\"2819\"\u003e2. Is this unit suitable for garage use?\u003c\/strong\u003e\u003cbr data-start=\"2819\" data-end=\"2822\"\u003eYes, it is specifically designed for garages, sheds, and small workshop applications.\u003c\/p\u003e\n\u003cp data-start=\"2909\" data-end=\"2999\"\u003e\u003cstrong data-start=\"2909\" data-end=\"2947\"\u003e3. Are MCBs included in this unit?\u003c\/strong\u003e\u003cbr data-start=\"2947\" data-end=\"2950\"\u003eYes, it comes with 6A and 16A MCBs pre-installed.\u003c\/p\u003e\n\u003cp data-start=\"3001\" data-end=\"3110\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3036\"\u003e4. Can the enclosure be locked?\u003c\/strong\u003e\u003cbr data-start=\"3036\" data-end=\"3039\"\u003eYes, it features a lockable metal design for added safety and security.\u003c\/p\u003e\n\u003cp data-start=\"3112\" data-end=\"3216\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3112\" data-end=\"3147\"\u003e5. Does it include wiring bars?\u003c\/strong\u003e\u003cbr data-start=\"3147\" data-end=\"3150\"\u003eYes, earth and neutral bars are included to simplify installation.\u003c\/p\u003e\n\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-98\" data-testid=\"conversation-turn-16\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"41aa9175-6000-45d2-9735-a1e5a5f1ee1d\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"332\" data-end=\"351\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"353\" data-end=\"781\"\u003eThe EMGU63616 Garage Consumer Unit is a compact and efficient electrical distribution solution designed for garages, sheds, and small workshop environments. Featuring a 5-module metal enclosure with 5 usable ways, this unit is pre-configured with essential protective devices, making it ideal for quick and hassle-free installation. Its sturdy construction ensures durability while maintaining a neat and organized wiring setup.\u003c\/p\u003e\n\u003cp data-start=\"783\" data-end=\"1153\"\u003eEquipped with a 63A 30mA RCD incomer along with 6A and 16A MCBs, this garage unit provides reliable protection against electrical faults and overloads. The inclusion of earth and neutral bars simplifies wiring, while the lockable enclosure enhances safety by restricting unauthorized access. It is a practical choice for managing smaller electrical circuits efficiently.\u003c\/p\u003e\n\u003chr data-start=\"1155\" data-end=\"1158\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1160\" data-end=\"1175\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1177\" data-end=\"1529\"\u003e\n\u003cli data-section-id=\"1ga1n1r\" data-start=\"1177\" data-end=\"1218\"\u003eCompact 5 module garage consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"no7d65\" data-start=\"1219\" data-end=\"1257\"\u003ePre-installed 63A 30mA RCD incomer\u003c\/li\u003e\n\u003cli data-section-id=\"4xxtmx\" data-start=\"1258\" data-end=\"1309\"\u003eIncludes 6A and 16A MCBs for circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"2pbbnp\" data-start=\"1310\" data-end=\"1355\"\u003eLockable metal enclosure for added safety\u003c\/li\u003e\n\u003cli data-section-id=\"80q1su\" data-start=\"1356\" data-end=\"1396\"\u003eSupplied with earth and neutral bars\u003c\/li\u003e\n\u003cli data-section-id=\"xjrdk6\" data-start=\"1397\" data-end=\"1440\"\u003eIdeal for garages, sheds, and workshops\u003c\/li\u003e\n\u003cli data-section-id=\"dt94t6\" data-start=\"1441\" data-end=\"1476\"\u003eDurable and robust construction\u003c\/li\u003e\n\u003cli data-section-id=\"1dcuwjm\" data-start=\"1477\" data-end=\"1529\"\u003eEasy installation with pre-configured components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1531\" data-end=\"1534\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1536\" data-end=\"1563\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1565\" data-end=\"1943\"\u003e\n\u003cli data-section-id=\"1y15d0z\" data-start=\"1565\" data-end=\"1585\"\u003eModel: EMGU63616\u003c\/li\u003e\n\u003cli data-section-id=\"lp4z29\" data-start=\"1586\" data-end=\"1619\"\u003eNumber of Ways: 5 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1v8jz61\" data-start=\"1620\" data-end=\"1659\"\u003eModule Capacity: 5 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1jh8x38\" data-start=\"1660\" data-end=\"1679\"\u003eRCD Rating: 63A\u003c\/li\u003e\n\u003cli data-section-id=\"orxwn9\" data-start=\"1680\" data-end=\"1705\"\u003eRCD Sensitivity: 30mA\u003c\/li\u003e\n\u003cli data-section-id=\"15oet27\" data-start=\"1706\" data-end=\"1755\"\u003eMCB Configuration:\n\u003cul data-start=\"1731\" data-end=\"1755\"\u003e\n\u003cli data-section-id=\"1sq6vee\" data-start=\"1731\" data-end=\"1741\"\u003e1 x 6A\u003c\/li\u003e\n\u003cli data-section-id=\"4x5w4n\" data-start=\"1744\" data-end=\"1755\"\u003e1 x 16A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15t787m\" data-start=\"1756\" data-end=\"1785\"\u003eMaterial: Metal enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1qhqc0s\" data-start=\"1786\" data-end=\"1803\"\u003eLockable: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1xadrsw\" data-start=\"1804\" data-end=\"1851\"\u003eIncluded Components: Earth and neutral bars\u003c\/li\u003e\n\u003cli data-section-id=\"xpatbw\" data-start=\"1852\" data-end=\"1911\"\u003eApplication: Garage and small outbuilding installations\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1912\" data-end=\"1943\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1945\" data-end=\"1948\"\u003e\n\u003ch2 data-section-id=\"y21iko\" data-start=\"1950\" data-end=\"1990\"\u003eWhy Choose This Garage Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"1992\" data-end=\"2315\"\u003eThis garage consumer unit offers a perfect balance of safety, convenience, and compact design. With a pre-installed RCD incomer and MCBs, it significantly reduces installation time while ensuring reliable protection for connected circuits. The 30mA RCD enhances user safety by quickly disconnecting power in case of faults.\u003c\/p\u003e\n\u003cp data-start=\"2317\" data-end=\"2585\"\u003eIts lockable metal enclosure adds an extra layer of security, making it ideal for environments where safety is essential. Designed for smaller electrical setups, it provides an efficient and dependable solution for managing power distribution in garages and workshops.\u003c\/p\u003e\n\u003chr data-start=\"2587\" data-end=\"2590\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2592\" data-end=\"2628\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2630\" data-end=\"2773\"\u003e\u003cstrong data-start=\"2630\" data-end=\"2679\"\u003e1. What protection does the 30mA RCD provide?\u003c\/strong\u003e\u003cbr data-start=\"2679\" data-end=\"2682\"\u003eIt protects against electric shock by quickly disconnecting power when a fault is detected.\u003c\/p\u003e\n\u003cp data-start=\"2775\" data-end=\"2907\"\u003e\u003cstrong data-start=\"2775\" data-end=\"2819\"\u003e2. Is this unit suitable for garage use?\u003c\/strong\u003e\u003cbr data-start=\"2819\" data-end=\"2822\"\u003eYes, it is specifically designed for garages, sheds, and small workshop applications.\u003c\/p\u003e\n\u003cp data-start=\"2909\" data-end=\"2999\"\u003e\u003cstrong data-start=\"2909\" data-end=\"2947\"\u003e3. Are MCBs included in this unit?\u003c\/strong\u003e\u003cbr data-start=\"2947\" data-end=\"2950\"\u003eYes, it comes with 6A and 16A MCBs pre-installed.\u003c\/p\u003e\n\u003cp data-start=\"3001\" data-end=\"3110\"\u003e\u003cstrong data-start=\"3001\" data-end=\"3036\"\u003e4. Can the enclosure be locked?\u003c\/strong\u003e\u003cbr data-start=\"3036\" data-end=\"3039\"\u003eYes, it features a lockable metal design for added safety and security.\u003c\/p\u003e\n\u003cp data-start=\"3112\" data-end=\"3216\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3112\" data-end=\"3147\"\u003e5. Does it include wiring bars?\u003c\/strong\u003e\u003cbr data-start=\"3147\" data-end=\"3150\"\u003eYes, earth and neutral bars are included to simplify installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"border-token-border-default mt-2 border-t py-4 text-sm\"\u003e\n\u003cdiv class=\"flex flex-col justify-between gap-3 mt-3\"\u003e\n\u003cdiv class=\"max-w-[480px] min-w-[300px]\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"border-token-border-default mt-2 border-t py-4 text-sm\"\u003e\n\u003cdiv class=\"flex flex-col justify-between gap-3 mt-3\"\u003e\n\u003cdiv class=\"max-w-[480px] min-w-[300px]\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289707422078,"sku":null,"price":21.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/25-31.png?v=1776703719"},{"product_id":"garage-consumer-unit-with-100a-main-switch-5-module-board","title":"Garage Consumer Unit with 100A Main Switch – 5 Module Board","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-99\" data-testid=\"conversation-turn-18\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"9bb135af-b494-4786-b7a4-d0ab59200d0e\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"343\" data-end=\"362\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"364\" data-end=\"772\"\u003eThe EMGUMS Garage Consumer Unit is a compact and reliable electrical distribution solution designed for garages, sheds, and small outbuildings. With a 5-module enclosure and 5 usable ways, it provides a simple yet effective setup for managing essential electrical circuits. Its sturdy metal construction ensures durability, making it well-suited for environments where protection and longevity are important.\u003c\/p\u003e\n\u003cp data-start=\"774\" data-end=\"1117\"\u003eThis unit is equipped with a 100A main switch incomer, allowing for easy isolation of the electrical supply when needed. Supplied with earth and neutral bars, it simplifies the wiring process for installers. The lockable enclosure adds an extra layer of safety, making it a practical and secure choice for small-scale electrical installations.\u003c\/p\u003e\n\u003chr data-start=\"1119\" data-end=\"1122\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1124\" data-end=\"1139\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1141\" data-end=\"1500\"\u003e\n\u003cli data-section-id=\"1ga1n1r\" data-start=\"1141\" data-end=\"1182\"\u003eCompact 5 module garage consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"1e173ha\" data-start=\"1183\" data-end=\"1236\"\u003e100A main switch incomer for easy power isolation\u003c\/li\u003e\n\u003cli data-section-id=\"9ldmf\" data-start=\"1237\" data-end=\"1281\"\u003e5 usable ways for flexible circuit setup\u003c\/li\u003e\n\u003cli data-section-id=\"1jbhe81\" data-start=\"1282\" data-end=\"1332\"\u003eLockable metal enclosure for enhanced security\u003c\/li\u003e\n\u003cli data-section-id=\"hdgult\" data-start=\"1333\" data-end=\"1368\"\u003eIncludes earth and neutral bars\u003c\/li\u003e\n\u003cli data-section-id=\"xh6ril\" data-start=\"1369\" data-end=\"1411\"\u003eDurable construction for long-term use\u003c\/li\u003e\n\u003cli data-section-id=\"xjrdk6\" data-start=\"1412\" data-end=\"1455\"\u003eIdeal for garages, sheds, and workshops\u003c\/li\u003e\n\u003cli data-section-id=\"75vw4a\" data-start=\"1456\" data-end=\"1500\"\u003eSimple and efficient installation design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1502\" data-end=\"1505\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1507\" data-end=\"1534\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1536\" data-end=\"1838\"\u003e\n\u003cli data-section-id=\"888ys9\" data-start=\"1536\" data-end=\"1553\"\u003eModel: EMGUMS\u003c\/li\u003e\n\u003cli data-section-id=\"lp4z29\" data-start=\"1554\" data-end=\"1587\"\u003eNumber of Ways: 5 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1v8jz61\" data-start=\"1588\" data-end=\"1627\"\u003eModule Capacity: 5 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1628\" data-end=\"1656\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"15t787m\" data-start=\"1657\" data-end=\"1686\"\u003eMaterial: Metal enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1qhqc0s\" data-start=\"1687\" data-end=\"1704\"\u003eLockable: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1xadrsw\" data-start=\"1705\" data-end=\"1752\"\u003eIncluded Components: Earth and neutral bars\u003c\/li\u003e\n\u003cli data-section-id=\"k68fsz\" data-start=\"1753\" data-end=\"1806\"\u003eApplication: Garage and outbuilding installations\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1807\" data-end=\"1838\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1840\" data-end=\"1843\"\u003e\n\u003ch2 data-section-id=\"y21iko\" data-start=\"1845\" data-end=\"1885\"\u003eWhy Choose This Garage Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"1887\" data-end=\"2169\"\u003eThis garage consumer unit is ideal for users who require a straightforward and dependable electrical distribution board with a high-capacity main switch. The 100A main switch allows for quick and safe isolation of the power supply, making maintenance and emergency shut-offs easier.\u003c\/p\u003e\n\u003cp data-start=\"2171\" data-end=\"2443\"\u003eIts lockable metal enclosure enhances safety, while the compact design makes it perfect for limited spaces. With included earth and neutral bars and a practical layout, it provides a convenient and secure solution for managing electrical circuits in smaller installations.\u003c\/p\u003e\n\u003chr data-start=\"2445\" data-end=\"2448\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2450\" data-end=\"2486\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2488\" data-end=\"2645\"\u003e\u003cstrong data-start=\"2488\" data-end=\"2539\"\u003e1. What is the purpose of the 100A main switch?\u003c\/strong\u003e\u003cbr data-start=\"2539\" data-end=\"2542\"\u003eThe 100A main switch allows you to safely isolate the electrical supply for maintenance or emergencies.\u003c\/p\u003e\n\u003cp data-start=\"2647\" data-end=\"2781\"\u003e\u003cstrong data-start=\"2647\" data-end=\"2698\"\u003e2. Is this unit suitable for garages and sheds?\u003c\/strong\u003e\u003cbr data-start=\"2698\" data-end=\"2701\"\u003eYes, it is specifically designed for garages, workshops, and small outbuildings.\u003c\/p\u003e\n\u003cp data-start=\"2783\" data-end=\"2900\"\u003e\u003cstrong data-start=\"2783\" data-end=\"2818\"\u003e3. Does this unit include MCBs?\u003c\/strong\u003e\u003cbr data-start=\"2818\" data-end=\"2821\"\u003eNo, it is supplied without MCBs, allowing you to customize the setup as needed.\u003c\/p\u003e\n\u003cp data-start=\"2902\" data-end=\"3009\"\u003e\u003cstrong data-start=\"2902\" data-end=\"2937\"\u003e4. Can the enclosure be locked?\u003c\/strong\u003e\u003cbr data-start=\"2937\" data-end=\"2940\"\u003eYes, the unit features a lockable metal enclosure for added security.\u003c\/p\u003e\n\u003cp data-start=\"3011\" data-end=\"3149\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3011\" data-end=\"3059\"\u003e5. Is professional installation recommended?\u003c\/strong\u003e\u003cbr data-start=\"3059\" data-end=\"3062\"\u003eYes, it should be installed by a qualified electrician to ensure safety and compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289724166526,"sku":null,"price":34.32,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EMGUMS616-side.png?v=1776704186"},{"product_id":"garage-consumer-unit-with-100a-main-switch-5-module-board-with-mcbs","title":"Garage Consumer Unit with 100A Main Switch – 5 Module Board with MCBs","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-100\" data-testid=\"conversation-turn-20\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"852b6ef0-8fef-404c-8d69-f2282f58e0c4\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"348\" data-end=\"367\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"369\" data-end=\"781\"\u003eThe EMGUMS616 Garage Consumer Unit is a compact and practical electrical distribution board designed for garages, workshops, and small outbuildings. With a 5-module enclosure and 5 usable ways, it offers an efficient solution for organizing and managing essential electrical circuits. Its robust metal construction ensures durability, making it ideal for environments where strength and reliability are required.\u003c\/p\u003e\n\u003cp data-start=\"783\" data-end=\"1180\"\u003eThis unit comes pre-equipped with a 100A main switch incomer along with 6A and 16A MCBs, providing both control and protection in one compact design. The inclusion of earth and neutral bars simplifies installation, while the lockable enclosure enhances safety by preventing unauthorized access. It is a dependable choice for small-scale electrical setups requiring both convenience and protection.\u003c\/p\u003e\n\u003chr data-start=\"1182\" data-end=\"1185\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1187\" data-end=\"1202\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1204\" data-end=\"1563\"\u003e\n\u003cli data-section-id=\"1ga1n1r\" data-start=\"1204\" data-end=\"1245\"\u003eCompact 5 module garage consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"1hfsnww\" data-start=\"1246\" data-end=\"1291\"\u003e100A main switch for safe power isolation\u003c\/li\u003e\n\u003cli data-section-id=\"4xxtmx\" data-start=\"1292\" data-end=\"1343\"\u003eIncludes 6A and 16A MCBs for circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"k5wjqr\" data-start=\"1344\" data-end=\"1388\"\u003e5 usable ways for flexible configuration\u003c\/li\u003e\n\u003cli data-section-id=\"ajb67j\" data-start=\"1389\" data-end=\"1436\"\u003eLockable metal enclosure for added security\u003c\/li\u003e\n\u003cli data-section-id=\"80q1su\" data-start=\"1437\" data-end=\"1477\"\u003eSupplied with earth and neutral bars\u003c\/li\u003e\n\u003cli data-section-id=\"168mjy2\" data-start=\"1478\" data-end=\"1519\"\u003eDurable and long-lasting construction\u003c\/li\u003e\n\u003cli data-section-id=\"xjrdk6\" data-start=\"1520\" data-end=\"1563\"\u003eIdeal for garages, sheds, and workshops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1565\" data-end=\"1568\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1570\" data-end=\"1597\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1599\" data-end=\"1954\"\u003e\n\u003cli data-section-id=\"srx0a0\" data-start=\"1599\" data-end=\"1619\"\u003eModel: EMGUMS616\u003c\/li\u003e\n\u003cli data-section-id=\"lp4z29\" data-start=\"1620\" data-end=\"1653\"\u003eNumber of Ways: 5 usable ways\u003c\/li\u003e\n\u003cli data-section-id=\"1v8jz61\" data-start=\"1654\" data-end=\"1693\"\u003eModule Capacity: 5 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1694\" data-end=\"1722\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"15oet27\" data-start=\"1723\" data-end=\"1772\"\u003eMCB Configuration:\n\u003cul data-start=\"1748\" data-end=\"1772\"\u003e\n\u003cli data-section-id=\"1sq6vee\" data-start=\"1748\" data-end=\"1758\"\u003e1 x 6A\u003c\/li\u003e\n\u003cli data-section-id=\"4x5w4n\" data-start=\"1761\" data-end=\"1772\"\u003e1 x 16A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15t787m\" data-start=\"1773\" data-end=\"1802\"\u003eMaterial: Metal enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1qhqc0s\" data-start=\"1803\" data-end=\"1820\"\u003eLockable: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1xadrsw\" data-start=\"1821\" data-end=\"1868\"\u003eIncluded Components: Earth and neutral bars\u003c\/li\u003e\n\u003cli data-section-id=\"k68fsz\" data-start=\"1869\" data-end=\"1922\"\u003eApplication: Garage and outbuilding installations\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1923\" data-end=\"1954\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1956\" data-end=\"1959\"\u003e\n\u003ch2 data-section-id=\"y21iko\" data-start=\"1961\" data-end=\"2001\"\u003eWhy Choose This Garage Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"2003\" data-end=\"2258\"\u003eThis garage consumer unit is a reliable and efficient choice for managing power in smaller installations. The 100A main switch provides easy control over the entire electrical supply, while the included MCBs ensure protection against overloads and faults.\u003c\/p\u003e\n\u003cp data-start=\"2260\" data-end=\"2524\"\u003eIts lockable metal enclosure enhances safety, making it suitable for environments where security is important. With pre-installed components and a compact design, it offers both convenience and performance, making it a practical solution for garages and workshops.\u003c\/p\u003e\n\u003chr data-start=\"2526\" data-end=\"2529\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2531\" data-end=\"2567\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2569\" data-end=\"2710\"\u003e\u003cstrong data-start=\"2569\" data-end=\"2610\"\u003e1. What does the 100A main switch do?\u003c\/strong\u003e\u003cbr data-start=\"2610\" data-end=\"2613\"\u003eIt allows you to quickly and safely isolate the electrical supply for maintenance or emergencies.\u003c\/p\u003e\n\u003cp data-start=\"2712\" data-end=\"2809\"\u003e\u003cstrong data-start=\"2712\" data-end=\"2750\"\u003e2. Are MCBs included in this unit?\u003c\/strong\u003e\u003cbr data-start=\"2750\" data-end=\"2753\"\u003eYes, it includes 6A and 16A MCBs for circuit protection.\u003c\/p\u003e\n\u003cp data-start=\"2811\" data-end=\"2936\"\u003e\u003cstrong data-start=\"2811\" data-end=\"2860\"\u003e3. Is this suitable for garage installations?\u003c\/strong\u003e\u003cbr data-start=\"2860\" data-end=\"2863\"\u003eYes, it is specifically designed for garages, sheds, and small workshops.\u003c\/p\u003e\n\u003cp data-start=\"2938\" data-end=\"3039\"\u003e\u003cstrong data-start=\"2938\" data-end=\"2973\"\u003e4. Can the enclosure be locked?\u003c\/strong\u003e\u003cbr data-start=\"2973\" data-end=\"2976\"\u003eYes, it features a lockable metal enclosure for added security.\u003c\/p\u003e\n\u003cp data-start=\"3041\" data-end=\"3182\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3041\" data-end=\"3086\"\u003e5. Is professional installation required?\u003c\/strong\u003e\u003cbr data-start=\"3086\" data-end=\"3089\"\u003eYes, installation should be carried out by a qualified electrician for safety and compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289739862398,"sku":null,"price":24.96,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EMGUMS616-side_9227b964-d091-4ad5-a363-4ac968fbab3c.png?v=1776704573"},{"product_id":"garage-consumer-unit-with-rcbo-spd-100a-main-switch","title":"Garage Consumer Unit with RCBO, SPD \u0026 100A Main Switch","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-101\" data-testid=\"conversation-turn-22\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"b511bcec-e97a-4793-8dd5-74a19e92facc\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"328\" data-end=\"347\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"349\" data-end=\"784\"\u003eThis 5 module garage consumer unit is a compact yet highly advanced electrical distribution solution designed for garages, workshops, and small outbuildings. It integrates essential protection devices into a single unit, including a 32A bi-directional RCBO, a 100A main switch, surge protection device (SPD), and a 32A MCB. This combination ensures both safety and efficiency in managing electrical loads within confined installations.\u003c\/p\u003e\n\u003cp data-start=\"786\" data-end=\"1188\"\u003eBuilt for modern electrical demands, this unit offers superior protection against overloads, earth faults, and voltage surges. Its compact 6-module board design makes it ideal for installations where space is limited, while still delivering robust performance. The inclusion of SPD further enhances protection for sensitive electrical equipment, making it a reliable choice for safe power distribution.\u003c\/p\u003e\n\u003chr data-start=\"1190\" data-end=\"1193\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1195\" data-end=\"1210\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1212\" data-end=\"1638\"\u003e\n\u003cli data-section-id=\"1bbivy5\" data-start=\"1212\" data-end=\"1279\"\u003eCompact garage consumer unit with integrated protection devices\u003c\/li\u003e\n\u003cli data-section-id=\"zhhj5s\" data-start=\"1280\" data-end=\"1335\"\u003e32A bi-directional RCBO for enhanced circuit safety\u003c\/li\u003e\n\u003cli data-section-id=\"1uz8a08\" data-start=\"1336\" data-end=\"1385\"\u003e100A main switch for complete power isolation\u003c\/li\u003e\n\u003cli data-section-id=\"14izanz\" data-start=\"1386\" data-end=\"1446\"\u003eBuilt-in SPD for surge protection against voltage spikes\u003c\/li\u003e\n\u003cli data-section-id=\"1bvu3b1\" data-start=\"1447\" data-end=\"1498\"\u003eIncludes 32A MCB for additional circuit control\u003c\/li\u003e\n\u003cli data-section-id=\"sigqbl\" data-start=\"1499\" data-end=\"1537\"\u003eSpace-saving 6 module board design\u003c\/li\u003e\n\u003cli data-section-id=\"xjrdk6\" data-start=\"1538\" data-end=\"1581\"\u003eIdeal for garages, sheds, and workshops\u003c\/li\u003e\n\u003cli data-section-id=\"1ournyw\" data-start=\"1582\" data-end=\"1638\"\u003eCombines safety, control, and efficiency in one unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1640\" data-end=\"1643\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1645\" data-end=\"1672\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1674\" data-end=\"2018\"\u003e\n\u003cli data-section-id=\"wp188e\" data-start=\"1674\" data-end=\"1712\"\u003eProduct Type: Garage Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"1fju1el\" data-start=\"1713\" data-end=\"1750\"\u003eModule Size: 5–6 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1751\" data-end=\"1779\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1odn07b\" data-start=\"1780\" data-end=\"1815\"\u003eRCBO Rating: 32A Bi-directional\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"1816\" data-end=\"1835\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"181dxef\" data-start=\"1836\" data-end=\"1872\"\u003eSurge Protection: Integrated SPD\u003c\/li\u003e\n\u003cli data-section-id=\"18q9cua\" data-start=\"1873\" data-end=\"1926\"\u003eEnclosure Type: Metal or industrial-grade housing\u003c\/li\u003e\n\u003cli data-section-id=\"xpatbw\" data-start=\"1927\" data-end=\"1986\"\u003eApplication: Garage and small outbuilding installations\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1987\" data-end=\"2018\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2020\" data-end=\"2023\"\u003e\n\u003ch2 data-section-id=\"y21iko\" data-start=\"2025\" data-end=\"2065\"\u003eWhy Choose This Garage Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"2067\" data-end=\"2359\"\u003eThis advanced garage consumer unit is ideal for users who require a high level of electrical protection in a compact format. The combination of RCBO and SPD ensures maximum safety by protecting against both electrical faults and power surges, reducing the risk of damage to connected devices.\u003c\/p\u003e\n\u003cp data-start=\"2361\" data-end=\"2617\"\u003eIts integrated design simplifies installation while offering strong performance and reliability. With a 100A main switch and multiple protective devices, it provides a complete and efficient solution for modern garage and workshop power distribution needs.\u003c\/p\u003e\n\u003chr data-start=\"2619\" data-end=\"2622\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2624\" data-end=\"2660\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2662\" data-end=\"2816\"\u003e\u003cstrong data-start=\"2662\" data-end=\"2720\"\u003e1. What is the benefit of having an RCBO in this unit?\u003c\/strong\u003e\u003cbr data-start=\"2720\" data-end=\"2723\"\u003eThe RCBO provides combined protection against overloads and earth leakage in a single device.\u003c\/p\u003e\n\u003cp data-start=\"2818\" data-end=\"2928\"\u003e\u003cstrong data-start=\"2818\" data-end=\"2846\"\u003e2. What does the SPD do?\u003c\/strong\u003e\u003cbr data-start=\"2846\" data-end=\"2849\"\u003eThe SPD protects electrical equipment from voltage spikes and transient surges.\u003c\/p\u003e\n\u003cp data-start=\"2930\" data-end=\"3067\"\u003e\u003cstrong data-start=\"2930\" data-end=\"2983\"\u003e3. Can this unit be used in a garage or workshop?\u003c\/strong\u003e\u003cbr data-start=\"2983\" data-end=\"2986\"\u003eYes, it is specifically designed for garages, workshops, and small installations.\u003c\/p\u003e\n\u003cp data-start=\"3069\" data-end=\"3182\"\u003e\u003cstrong data-start=\"3069\" data-end=\"3115\"\u003e4. Does this unit include a main isolator?\u003c\/strong\u003e\u003cbr data-start=\"3115\" data-end=\"3118\"\u003eYes, it comes with a 100A main switch for full system isolation.\u003c\/p\u003e\n\u003cp data-start=\"3184\" data-end=\"3332\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3184\" data-end=\"3229\"\u003e5. Is professional installation required?\u003c\/strong\u003e\u003cbr data-start=\"3229\" data-end=\"3232\"\u003eYes, installation should always be carried out by a qualified electrician for safety and compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289746121086,"sku":null,"price":49.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EV32MS-small.png?v=1776704933"},{"product_id":"6-module-garage-consumer-unit-with-rcbo-spd-100a-switch","title":"6 Module Garage Consumer Unit with RCBO, SPD \u0026 100A Switch","description":"\u003ch2 data-section-id=\"1p927wt\" data-start=\"335\" data-end=\"354\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"356\" data-end=\"768\"\u003eThe EV40MS 6 Module Distribution Board is a compact yet powerful garage consumer unit designed for safe and efficient electrical distribution. It integrates essential protection features including a 40A bi-directional RCBO, a 100A main switch, surge protection device (SPD), and a 32A MCB. This combination ensures a high level of safety while maintaining a space-saving design suitable for modern installations.\u003c\/p\u003e\n\u003cp data-start=\"770\" data-end=\"1150\"\u003eEngineered for garages, workshops, and small outbuildings, this unit delivers dependable protection against electrical faults, overloads, and voltage surges. Its 6 module configuration makes it ideal for installations where space is limited but performance cannot be compromised. The inclusion of SPD enhances protection for sensitive equipment, ensuring long-lasting reliability.\u003c\/p\u003e\n\u003chr data-start=\"1152\" data-end=\"1155\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1157\" data-end=\"1172\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1174\" data-end=\"1598\"\u003e\n\u003cli data-section-id=\"qx9ftg\" data-start=\"1174\" data-end=\"1220\"\u003eCompact 6 module garage distribution board\u003c\/li\u003e\n\u003cli data-section-id=\"1f20nm2\" data-start=\"1221\" data-end=\"1280\"\u003e40A bi-directional RCBO for advanced circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"bx0ak2\" data-start=\"1281\" data-end=\"1326\"\u003e100A main switch for full power isolation\u003c\/li\u003e\n\u003cli data-section-id=\"hf4dx7\" data-start=\"1327\" data-end=\"1384\"\u003eIntegrated SPD for surge and voltage spike protection\u003c\/li\u003e\n\u003cli data-section-id=\"1bvu3b1\" data-start=\"1385\" data-end=\"1436\"\u003eIncludes 32A MCB for additional circuit control\u003c\/li\u003e\n\u003cli data-section-id=\"1yt9nxg\" data-start=\"1437\" data-end=\"1493\"\u003eSpace-efficient design ideal for small installations\u003c\/li\u003e\n\u003cli data-section-id=\"y29o42\" data-start=\"1494\" data-end=\"1540\"\u003eSuitable for garages, sheds, and workshops\u003c\/li\u003e\n\u003cli data-section-id=\"tnianz\" data-start=\"1541\" data-end=\"1598\"\u003eCombines safety, control, and reliability in one unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1600\" data-end=\"1603\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1605\" data-end=\"1632\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1634\" data-end=\"1932\"\u003e\n\u003cli data-section-id=\"12qk1ue\" data-start=\"1634\" data-end=\"1649\"\u003eSKU: EV40MS\u003c\/li\u003e\n\u003cli data-section-id=\"16cza3\" data-start=\"1650\" data-end=\"1685\"\u003eModule Size: 6 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"fajvxe\" data-start=\"1686\" data-end=\"1721\"\u003eRCBO Rating: 40A Bi-directional\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1722\" data-end=\"1750\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"1751\" data-end=\"1770\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"5b6i8c\" data-start=\"1771\" data-end=\"1805\"\u003eSurge Protection: Built-in SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1lexva9\" data-start=\"1806\" data-end=\"1850\"\u003eEnclosure Type: Metal distribution board\u003c\/li\u003e\n\u003cli data-section-id=\"12ufguo\" data-start=\"1851\" data-end=\"1900\"\u003eApplication: Garage and small outbuilding use\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1901\" data-end=\"1932\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1934\" data-end=\"1937\"\u003e\n\u003ch2 data-section-id=\"y21iko\" data-start=\"1939\" data-end=\"1979\"\u003eWhy Choose This Garage Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"1981\" data-end=\"2203\"\u003eThis 6 module garage consumer unit is designed for users who need maximum protection in a compact form. The combination of RCBO and SPD ensures dual-layer safety, protecting both against electrical faults and power surges.\u003c\/p\u003e\n\u003cp data-start=\"2205\" data-end=\"2481\"\u003eIts 100A main switch allows complete system isolation, making maintenance and safety control simple and effective. With its compact design and integrated protective devices, it is an excellent choice for modern garage and workshop installations requiring reliable performance.\u003c\/p\u003e\n\u003chr data-start=\"2483\" data-end=\"2486\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2488\" data-end=\"2524\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2526\" data-end=\"2674\"\u003e\u003cstrong data-start=\"2526\" data-end=\"2575\"\u003e1. What is the role of the RCBO in this unit?\u003c\/strong\u003e\u003cbr data-start=\"2575\" data-end=\"2578\"\u003eThe RCBO provides protection against both overloads and earth leakage faults in a single device.\u003c\/p\u003e\n\u003cp data-start=\"2676\" data-end=\"2806\"\u003e\u003cstrong data-start=\"2676\" data-end=\"2726\"\u003e2. Why is SPD important in this consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"2726\" data-end=\"2729\"\u003eThe SPD protects connected equipment from damaging voltage surges and spikes.\u003c\/p\u003e\n\u003cp data-start=\"2808\" data-end=\"2937\"\u003e\u003cstrong data-start=\"2808\" data-end=\"2852\"\u003e3. Is this unit suitable for garage use?\u003c\/strong\u003e\u003cbr data-start=\"2852\" data-end=\"2855\"\u003eYes, it is specifically designed for garages, workshops, and similar environments.\u003c\/p\u003e\n\u003cp data-start=\"2939\" data-end=\"3055\"\u003e\u003cstrong data-start=\"2939\" data-end=\"2985\"\u003e4. Does it include a main isolator switch?\u003c\/strong\u003e\u003cbr data-start=\"2985\" data-end=\"2988\"\u003eYes, it comes with a 100A main switch for complete power isolation.\u003c\/p\u003e\n\u003cp data-start=\"3057\" data-end=\"3194\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3057\" data-end=\"3113\"\u003e5. Should a qualified electrician install this unit?\u003c\/strong\u003e\u003cbr data-start=\"3113\" data-end=\"3116\"\u003eYes, professional installation is recommended to ensure safety and compliance.\u003c\/p\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289757032830,"sku":null,"price":49.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EV32MS-small_fffd0d0c-bc50-4a8a-822b-4972b99ac69b.png?v=1776705281"},{"product_id":"5-module-garage-consumer-unit-with-rcbo-spd-100a-switch","title":"5 Module Garage Consumer Unit with RCBO, SPD \u0026 100A Switch","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:514c4757-f8d2-4d8b-967f-45fbb726d16f-104\" data-testid=\"conversation-turn-26\" data-scroll-anchor=\"true\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"f4aef835-af67-42b6-ba94-22a2fb875a33\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"1p927wt\" data-start=\"337\" data-end=\"356\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"358\" data-end=\"775\"\u003eThe EV32MS-G 5 Module Garage Consumer Unit is a compact and efficient electrical distribution solution designed for garages, workshops, and small utility spaces. It integrates essential protective components including a 32A bi-directional RCBO, a 100A main switch, a surge protection device (SPD), and a 32A MCB. This combination ensures strong electrical safety while maintaining a space-saving and practical design.\u003c\/p\u003e\n\u003cp data-start=\"777\" data-end=\"1151\"\u003eBuilt for modern installations, this unit provides reliable protection against overloads, earth leakage, and voltage surges. Its compact 5-module structure makes it ideal for installations where space is limited, yet high safety standards are required. The integrated SPD helps safeguard sensitive equipment, making it a dependable choice for small-scale electrical systems.\u003c\/p\u003e\n\u003chr data-start=\"1153\" data-end=\"1156\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1158\" data-end=\"1173\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1175\" data-end=\"1548\"\u003e\n\u003cli data-section-id=\"1ga1n1r\" data-start=\"1175\" data-end=\"1216\"\u003eCompact 5 module garage consumer unit\u003c\/li\u003e\n\u003cli data-section-id=\"1ae0u58\" data-start=\"1217\" data-end=\"1268\"\u003e32A bi-directional RCBO for advanced protection\u003c\/li\u003e\n\u003cli data-section-id=\"1945jj7\" data-start=\"1269\" data-end=\"1319\"\u003e100A main switch for full electrical isolation\u003c\/li\u003e\n\u003cli data-section-id=\"xvvvcm\" data-start=\"1320\" data-end=\"1359\"\u003eIntegrated SPD for surge protection\u003c\/li\u003e\n\u003cli data-section-id=\"fv115w\" data-start=\"1360\" data-end=\"1400\"\u003eIncludes 32A MCB for circuit control\u003c\/li\u003e\n\u003cli data-section-id=\"83secg\" data-start=\"1401\" data-end=\"1454\"\u003eSpace-saving design ideal for tight installations\u003c\/li\u003e\n\u003cli data-section-id=\"y29o42\" data-start=\"1455\" data-end=\"1501\"\u003eSuitable for garages, sheds, and workshops\u003c\/li\u003e\n\u003cli data-section-id=\"ue46n3\" data-start=\"1502\" data-end=\"1548\"\u003eCombines safety and efficiency in one unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1550\" data-end=\"1553\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1555\" data-end=\"1582\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1584\" data-end=\"1884\"\u003e\n\u003cli data-section-id=\"ie4b95\" data-start=\"1584\" data-end=\"1601\"\u003eSKU: EV32MS-G\u003c\/li\u003e\n\u003cli data-section-id=\"1gp3uns\" data-start=\"1602\" data-end=\"1637\"\u003eModule Size: 5 module enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1odn07b\" data-start=\"1638\" data-end=\"1673\"\u003eRCBO Rating: 32A Bi-directional\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1674\" data-end=\"1702\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"1703\" data-end=\"1722\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"5b6i8c\" data-start=\"1723\" data-end=\"1757\"\u003eSurge Protection: Built-in SPD\u003c\/li\u003e\n\u003cli data-section-id=\"1lexva9\" data-start=\"1758\" data-end=\"1802\"\u003eEnclosure Type: Metal distribution board\u003c\/li\u003e\n\u003cli data-section-id=\"12ufguo\" data-start=\"1803\" data-end=\"1852\"\u003eApplication: Garage and small outbuilding use\u003c\/li\u003e\n\u003cli data-section-id=\"1tv27gw\" data-start=\"1853\" data-end=\"1884\"\u003eMounting Type: Wall-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1886\" data-end=\"1889\"\u003e\n\u003ch2 data-section-id=\"y21iko\" data-start=\"1891\" data-end=\"1931\"\u003eWhy Choose This Garage Consumer Unit?\u003c\/h2\u003e\n\u003cp data-start=\"1933\" data-end=\"2167\"\u003eThis garage consumer unit is ideal for users who need a compact yet highly protective electrical solution. The integration of RCBO and SPD ensures dual-layer safety, protecting both against electrical faults and damaging power surges.\u003c\/p\u003e\n\u003cp data-start=\"2169\" data-end=\"2404\"\u003eIts 100A main switch provides complete control over the power supply, making maintenance safer and more convenient. Designed for reliability and efficiency, it is a strong choice for modern garage and workshop electrical installations.\u003c\/p\u003e\n\u003chr data-start=\"2406\" data-end=\"2409\"\u003e\n\u003ch2 data-section-id=\"1qsfy1n\" data-start=\"2411\" data-end=\"2447\"\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp data-start=\"2449\" data-end=\"2570\"\u003e\u003cstrong data-start=\"2449\" data-end=\"2494\"\u003e1. What protection does the RCBO provide?\u003c\/strong\u003e\u003cbr data-start=\"2494\" data-end=\"2497\"\u003eIt protects against both earth leakage and overload faults in one device.\u003c\/p\u003e\n\u003cp data-start=\"2572\" data-end=\"2684\"\u003e\u003cstrong data-start=\"2572\" data-end=\"2612\"\u003e2. Why is SPD included in this unit?\u003c\/strong\u003e\u003cbr data-start=\"2612\" data-end=\"2615\"\u003eThe SPD protects electrical equipment from voltage spikes and surges.\u003c\/p\u003e\n\u003cp data-start=\"2686\" data-end=\"2817\"\u003e\u003cstrong data-start=\"2686\" data-end=\"2740\"\u003e3. Is this unit suitable for garage installations?\u003c\/strong\u003e\u003cbr data-start=\"2740\" data-end=\"2743\"\u003eYes, it is specifically designed for garages, sheds, and small workspaces.\u003c\/p\u003e\n\u003cp data-start=\"2819\" data-end=\"2923\"\u003e\u003cstrong data-start=\"2819\" data-end=\"2856\"\u003e4. Does it include a main switch?\u003c\/strong\u003e\u003cbr data-start=\"2856\" data-end=\"2859\"\u003eYes, it comes with a 100A main switch for full system isolation.\u003c\/p\u003e\n\u003cp data-start=\"2925\" data-end=\"3054\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2925\" data-end=\"2970\"\u003e5. Is professional installation required?\u003c\/strong\u003e\u003cbr data-start=\"2970\" data-end=\"2973\"\u003eYes, it should be installed by a qualified electrician for safety and compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289778069886,"sku":null,"price":40.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EV32MS-small_1561f75e-6030-4f15-b89e-72fa317b6d82.png?v=1776705663"},{"product_id":"5-module-garage-consumer-unit-with-40a-rcbo-100a-main-switch-spd","title":"5 Module Garage Consumer Unit with 40A RCBO 100A Main Switch SPD","description":"\u003ch2 data-section-id=\"rzkdgm\" data-start=\"249\" data-end=\"260\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"262\" data-end=\"608\"\u003eThis 5 module garage consumer unit is designed to deliver safe, efficient, and reliable power distribution for residential garages, workshops, and outbuildings. It comes fully equipped with a 100A main switch, 40A bi-directional RCBO, surge protection device (SPD), and a 32A MCB, ensuring complete electrical protection in one compact enclosure.\u003c\/p\u003e\n\u003cp data-start=\"610\" data-end=\"904\"\u003eBuilt for modern electrical installations, this unit offers robust protection against overloads, short circuits, and voltage surges. Its compact 5-module design makes it ideal for installations where space is limited while still providing high-performance circuit control and safety compliance.\u003c\/p\u003e\n\u003chr data-start=\"906\" data-end=\"909\"\u003e\n\u003ch2 data-section-id=\"1usr32o\" data-start=\"911\" data-end=\"947\"\u003eWhy Choose a Garage Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"949\" data-end=\"1194\"\u003eChoosing this garage consumer unit ensures enhanced safety, durability, and convenience for your electrical setup. It is engineered to meet modern wiring regulations and provides a streamlined solution for managing multiple circuits efficiently.\u003c\/p\u003e\n\u003cp data-start=\"1196\" data-end=\"1418\"\u003eWith integrated protection devices including RCBO and SPD, it significantly reduces the risk of electrical faults and damage to connected equipment, making it a dependable choice for both domestic and light commercial use.\u003c\/p\u003e\n\u003chr data-start=\"1420\" data-end=\"1423\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1425\" data-end=\"1440\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1442\" data-end=\"1843\"\u003e\n\u003cli data-section-id=\"15r6nct\" data-start=\"1442\" data-end=\"1490\"\u003e5 module compact garage consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"e3pd5a\" data-start=\"1491\" data-end=\"1542\"\u003e100A double pole main switch for full isolation\u003c\/li\u003e\n\u003cli data-section-id=\"c0h1pe\" data-start=\"1543\" data-end=\"1594\"\u003e40A bi-directional RCBO for combined protection\u003c\/li\u003e\n\u003cli data-section-id=\"10e00a7\" data-start=\"1595\" data-end=\"1637\"\u003eBuilt-in surge protection device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"9nx2sw\" data-start=\"1638\" data-end=\"1679\"\u003e32A MCB for dedicated circuit control\u003c\/li\u003e\n\u003cli data-section-id=\"wbigj7\" data-start=\"1680\" data-end=\"1739\"\u003eEnhanced protection against overload and short circuits\u003c\/li\u003e\n\u003cli data-section-id=\"ntbwxb\" data-start=\"1740\" data-end=\"1789\"\u003eSuitable for garages, sheds, and outbuildings\u003c\/li\u003e\n\u003cli data-section-id=\"3t2whl\" data-start=\"1790\" data-end=\"1843\"\u003eEasy installation and maintenance friendly design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1845\" data-end=\"1848\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1850\" data-end=\"1877\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1879\" data-end=\"2249\"\u003e\n\u003cli data-section-id=\"wp188e\" data-start=\"1879\" data-end=\"1917\"\u003eProduct Type: Garage Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"l7q3fo\" data-start=\"1918\" data-end=\"1942\"\u003eNumber of Modules: 5\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"1943\" data-end=\"1971\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"fajvxe\" data-start=\"1972\" data-end=\"2007\"\u003eRCBO Rating: 40A Bi-directional\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"2008\" data-end=\"2027\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"n2zcdc\" data-start=\"2028\" data-end=\"2067\"\u003eSurge Protection: Type SPD included\u003c\/li\u003e\n\u003cli data-section-id=\"c64bjz\" data-start=\"2068\" data-end=\"2100\"\u003eMounting Type: Surface mount\u003c\/li\u003e\n\u003cli data-section-id=\"q8dxi9\" data-start=\"2101\" data-end=\"2149\"\u003eApplication: Domestic \u0026amp; light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"1229ffg\" data-start=\"2150\" data-end=\"2192\"\u003eMaterial: High-grade durable enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"1nm9yuw\" data-start=\"2193\" data-end=\"2249\"\u003eProtection Class: IP-rated enclosure (varies by model)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2251\" data-end=\"2254\"\u003e\n\u003ch2 data-section-id=\"1xvwnkw\" data-start=\"2256\" data-end=\"2263\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2265\" data-end=\"2428\"\u003e\u003cstrong data-start=\"2265\" data-end=\"2321\"\u003e1. What is a 5 module garage consumer unit used for?\u003c\/strong\u003e\u003cbr data-start=\"2321\" data-end=\"2324\"\u003eIt is used to safely distribute and control electrical circuits in garages, workshops, and outbuildings.\u003c\/p\u003e\n\u003cp data-start=\"2430\" data-end=\"2562\"\u003e\u003cstrong data-start=\"2430\" data-end=\"2477\"\u003e2. Does this unit include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2477\" data-end=\"2480\"\u003eYes, it comes with an integrated SPD to protect against voltage spikes and surges.\u003c\/p\u003e\n\u003cp data-start=\"2564\" data-end=\"2690\"\u003e\u003cstrong data-start=\"2564\" data-end=\"2606\"\u003e3. What does the RCBO do in this unit?\u003c\/strong\u003e\u003cbr data-start=\"2606\" data-end=\"2609\"\u003eThe RCBO provides both overload and earth leakage protection for enhanced safety.\u003c\/p\u003e\n\u003cp data-start=\"2692\" data-end=\"2850\"\u003e\u003cstrong data-start=\"2692\" data-end=\"2741\"\u003e4. Is this unit suitable for outdoor garages?\u003c\/strong\u003e\u003cbr data-start=\"2741\" data-end=\"2744\"\u003eYes, it is designed for garage and outbuilding installations, depending on enclosure rating and placement.\u003c\/p\u003e\n\u003cp data-start=\"2852\" data-end=\"2977\"\u003e\u003cstrong data-start=\"2852\" data-end=\"2892\"\u003e5. Can additional circuits be added?\u003c\/strong\u003e\u003cbr data-start=\"2892\" data-end=\"2895\"\u003eYes, depending on load requirements and spare capacity within the 5-module layout.\u003c\/p\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289893806462,"sku":null,"price":40.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EV40MS-G-2.png?v=1776708365"},{"product_id":"5-module-garage-unit-with-63a-type-b-rcd-spd-32a-mcb","title":"5 Module Garage Unit with 63A Type B RCD, SPD \u0026 32A MCB","description":"\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69e66ac6-9a24-83ea-8954-2d17747d97ea-1\" data-testid=\"conversation-turn-6\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"57fdad2d-0ba4-4bb9-abf4-068f411c1758\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"rzkdgm\" data-start=\"360\" data-end=\"371\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"373\" data-end=\"687\"\u003eThis 5 module garage consumer unit is a compact and efficient solution designed for safe electrical distribution in garages, workshops, and outbuildings. Featuring a 63A Type B RCD, surge protection device (SPD), and a 32A MCB, it ensures reliable protection against electrical faults, overloads, and power surges.\u003c\/p\u003e\n\u003cp data-start=\"689\" data-end=\"981\"\u003eEngineered for modern electrical installations, this unit (SKU: EV32RBS) offers a space-saving design without compromising safety or performance. It provides dependable circuit control, making it ideal for domestic and light commercial applications where safety and reliability are essential.\u003c\/p\u003e\n\u003chr data-start=\"983\" data-end=\"986\"\u003e\n\u003ch2 data-section-id=\"1usr32o\" data-start=\"988\" data-end=\"1024\"\u003eWhy Choose a Garage Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1026\" data-end=\"1295\"\u003eChoosing this garage consumer unit means investing in enhanced electrical safety and long-term reliability. It is designed to meet modern wiring requirements, offering complete protection for connected circuits while maintaining a compact and easy-to-install structure.\u003c\/p\u003e\n\u003cp data-start=\"1297\" data-end=\"1544\"\u003eWith integrated RCD and SPD protection, it safeguards your electrical system and appliances from faults and voltage spikes. This makes it a smart choice for users seeking dependable performance and peace of mind in garage or external power setups.\u003c\/p\u003e\n\u003chr data-start=\"1546\" data-end=\"1549\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1551\" data-end=\"1566\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1568\" data-end=\"1949\"\u003e\n\u003cli data-section-id=\"15r6nct\" data-start=\"1568\" data-end=\"1616\"\u003e5 module compact garage consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"1kmsy9w\" data-start=\"1617\" data-end=\"1666\"\u003e63A Type B RCD for enhanced electrical safety\u003c\/li\u003e\n\u003cli data-section-id=\"10e00a7\" data-start=\"1667\" data-end=\"1709\"\u003eBuilt-in surge protection device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"20ua8k\" data-start=\"1710\" data-end=\"1754\"\u003e32A MCB for dedicated circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1ac5766\" data-start=\"1755\" data-end=\"1806\"\u003eProtection against overloads and short circuits\u003c\/li\u003e\n\u003cli data-section-id=\"vukbhv\" data-start=\"1807\" data-end=\"1845\"\u003eCompact and space-saving enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"ntbwxb\" data-start=\"1846\" data-end=\"1895\"\u003eSuitable for garages, sheds, and outbuildings\u003c\/li\u003e\n\u003cli data-section-id=\"1sg05zw\" data-start=\"1896\" data-end=\"1949\"\u003eEasy installation and maintenance-friendly layout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1951\" data-end=\"1954\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1956\" data-end=\"1983\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1985\" data-end=\"2336\"\u003e\n\u003cli data-section-id=\"wp188e\" data-start=\"1985\" data-end=\"2023\"\u003eProduct Type: Garage Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"xfquum\" data-start=\"2024\" data-end=\"2040\"\u003eSKU: EV32RBS\u003c\/li\u003e\n\u003cli data-section-id=\"l7q3fo\" data-start=\"2041\" data-end=\"2065\"\u003eNumber of Modules: 5\u003c\/li\u003e\n\u003cli data-section-id=\"1s68qri\" data-start=\"2066\" data-end=\"2092\"\u003eRCD Rating: 63A Type B\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"2093\" data-end=\"2112\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"181dxef\" data-start=\"2113\" data-end=\"2149\"\u003eSurge Protection: Integrated SPD\u003c\/li\u003e\n\u003cli data-section-id=\"15c7b1a\" data-start=\"2150\" data-end=\"2184\"\u003eMounting Type: Surface mounted\u003c\/li\u003e\n\u003cli data-section-id=\"q8dxi9\" data-start=\"2185\" data-end=\"2233\"\u003eApplication: Domestic \u0026amp; light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"2dk7wx\" data-start=\"2234\" data-end=\"2275\"\u003eEnclosure: Durable protective housing\u003c\/li\u003e\n\u003cli data-section-id=\"170fjwn\" data-start=\"2276\" data-end=\"2336\"\u003eCompliance: Designed to meet modern electrical standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2338\" data-end=\"2341\"\u003e\n\u003ch2 data-section-id=\"1xvwnkw\" data-start=\"2343\" data-end=\"2350\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2352\" data-end=\"2517\"\u003e\u003cstrong data-start=\"2352\" data-end=\"2408\"\u003e1. What is the purpose of this garage consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"2408\" data-end=\"2411\"\u003eIt provides safe and efficient distribution of electricity for garages, workshops, and external buildings.\u003c\/p\u003e\n\u003cp data-start=\"2519\" data-end=\"2643\"\u003e\u003cstrong data-start=\"2519\" data-end=\"2563\"\u003e2. What protection does the RCD provide?\u003c\/strong\u003e\u003cbr data-start=\"2563\" data-end=\"2566\"\u003eThe 63A Type B RCD protects against earth leakage and electrical shock risks.\u003c\/p\u003e\n\u003cp data-start=\"2645\" data-end=\"2774\"\u003e\u003cstrong data-start=\"2645\" data-end=\"2692\"\u003e3. Does this unit include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2692\" data-end=\"2695\"\u003eYes, it comes with a built-in SPD to protect against voltage spikes and surges.\u003c\/p\u003e\n\u003cp data-start=\"2776\" data-end=\"2921\"\u003e\u003cstrong data-start=\"2776\" data-end=\"2826\"\u003e4. Is this suitable for outdoor installations?\u003c\/strong\u003e\u003cbr data-start=\"2826\" data-end=\"2829\"\u003eIt is ideal for garages and outbuildings when installed in a suitable protected environment.\u003c\/p\u003e\n\u003cp data-start=\"2923\" data-end=\"3069\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2923\" data-end=\"2974\"\u003e5. Can this unit handle heavy electrical loads?\u003c\/strong\u003e\u003cbr data-start=\"2974\" data-end=\"2977\"\u003eYes, the 32A MCB and 63A RCD provide reliable control for typical garage power requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289909207422,"sku":null,"price":104.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EV32MS-small_8d8f555a-211b-437b-bec7-ec196477ef09.png?v=1776708959"},{"product_id":"5-module-garage-unit-with-63a-type-b-rcd-spd-40a-mcb","title":"5 Module Garage Unit with 63A Type B RCD, SPD \u0026 40A MCB","description":"\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69e66ac6-9a24-83ea-8954-2d17747d97ea-2\" data-testid=\"conversation-turn-8\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"65405949-b0e1-4be1-a4b6-c0eb9248a60d\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"rzkdgm\" data-start=\"357\" data-end=\"368\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"370\" data-end=\"734\"\u003eThis 5 module garage consumer unit is a high-performance electrical distribution solution designed for safe and efficient power management in garages, workshops, and outbuildings. It comes equipped with a 63A Type B RCD, a 40A MCB, and integrated surge protection device (SPD) to ensure complete protection against electrical faults, overloads, and voltage surges.\u003c\/p\u003e\n\u003cp data-start=\"736\" data-end=\"991\"\u003eBuilt under SKU: EV40RBS, this compact unit is engineered to deliver reliable circuit control while maintaining a space-saving design. It is ideal for modern installations where safety, compliance, and durability are essential for everyday electrical use.\u003c\/p\u003e\n\u003chr data-start=\"993\" data-end=\"996\"\u003e\n\u003ch2 data-section-id=\"1usr32o\" data-start=\"998\" data-end=\"1034\"\u003eWhy Choose a Garage Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"1036\" data-end=\"1313\"\u003eChoosing this garage consumer unit ensures advanced protection and dependable electrical performance for both residential and light commercial environments. It is designed to meet modern electrical safety standards while offering a simple and efficient installation experience.\u003c\/p\u003e\n\u003cp data-start=\"1315\" data-end=\"1552\"\u003eWith integrated RCD and SPD protection, this unit helps safeguard connected equipment from electrical shocks, overloads, and sudden power surges. It provides peace of mind and long-term reliability for any garage or external power setup.\u003c\/p\u003e\n\u003chr data-start=\"1554\" data-end=\"1557\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1559\" data-end=\"1574\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1576\" data-end=\"1962\"\u003e\n\u003cli data-section-id=\"1i6vy2l\" data-start=\"1576\" data-end=\"1624\"\u003eCompact 5 module garage consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"12w4hbd\" data-start=\"1625\" data-end=\"1674\"\u003e63A Type B RCD for enhanced safety protection\u003c\/li\u003e\n\u003cli data-section-id=\"81wal5\" data-start=\"1675\" data-end=\"1722\"\u003e40A MCB for controlled circuit distribution\u003c\/li\u003e\n\u003cli data-section-id=\"10e00a7\" data-start=\"1723\" data-end=\"1765\"\u003eBuilt-in surge protection device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"1ac5766\" data-start=\"1766\" data-end=\"1817\"\u003eProtection against overloads and short circuits\u003c\/li\u003e\n\u003cli data-section-id=\"ntbwxb\" data-start=\"1818\" data-end=\"1867\"\u003eSuitable for garages, sheds, and outbuildings\u003c\/li\u003e\n\u003cli data-section-id=\"11kqqdh\" data-start=\"1868\" data-end=\"1908\"\u003eDurable and compact enclosure design\u003c\/li\u003e\n\u003cli data-section-id=\"1sg05zw\" data-start=\"1909\" data-end=\"1962\"\u003eEasy installation and maintenance-friendly layout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1964\" data-end=\"1967\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1969\" data-end=\"1996\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1998\" data-end=\"2373\"\u003e\n\u003cli data-section-id=\"wp188e\" data-start=\"1998\" data-end=\"2036\"\u003eProduct Type: Garage Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"6pctn\" data-start=\"2037\" data-end=\"2053\"\u003eSKU: EV40RBS\u003c\/li\u003e\n\u003cli data-section-id=\"l7q3fo\" data-start=\"2054\" data-end=\"2078\"\u003eNumber of Modules: 5\u003c\/li\u003e\n\u003cli data-section-id=\"1s68qri\" data-start=\"2079\" data-end=\"2105\"\u003eRCD Rating: 63A Type B\u003c\/li\u003e\n\u003cli data-section-id=\"1etzdh8\" data-start=\"2106\" data-end=\"2125\"\u003eMCB Rating: 40A\u003c\/li\u003e\n\u003cli data-section-id=\"181dxef\" data-start=\"2126\" data-end=\"2162\"\u003eSurge Protection: Integrated SPD\u003c\/li\u003e\n\u003cli data-section-id=\"15c7b1a\" data-start=\"2163\" data-end=\"2197\"\u003eMounting Type: Surface mounted\u003c\/li\u003e\n\u003cli data-section-id=\"g8pbt8\" data-start=\"2198\" data-end=\"2248\"\u003eApplication: Domestic and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"xefxp9\" data-start=\"2249\" data-end=\"2304\"\u003eEnclosure Material: High-strength insulated housing\u003c\/li\u003e\n\u003cli data-section-id=\"1hacfd9\" data-start=\"2305\" data-end=\"2373\"\u003eCompliance: Designed to meet current electrical safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2375\" data-end=\"2378\"\u003e\n\u003ch2 data-section-id=\"1xvwnkw\" data-start=\"2380\" data-end=\"2387\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2389\" data-end=\"2532\"\u003e\u003cstrong data-start=\"2389\" data-end=\"2439\"\u003e1. What is this garage consumer unit used for?\u003c\/strong\u003e\u003cbr data-start=\"2439\" data-end=\"2442\"\u003eIt is used for safe electrical distribution in garages, workshops, and external buildings.\u003c\/p\u003e\n\u003cp data-start=\"2534\" data-end=\"2665\"\u003e\u003cstrong data-start=\"2534\" data-end=\"2589\"\u003e2. What protection does the 63A Type B RCD provide?\u003c\/strong\u003e\u003cbr data-start=\"2589\" data-end=\"2592\"\u003eIt protects against earth leakage and reduces the risk of electric shock.\u003c\/p\u003e\n\u003cp data-start=\"2667\" data-end=\"2783\"\u003e\u003cstrong data-start=\"2667\" data-end=\"2714\"\u003e3. Does this unit include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2714\" data-end=\"2717\"\u003eYes, it includes a built-in SPD to protect against voltage spikes.\u003c\/p\u003e\n\u003cp data-start=\"2785\" data-end=\"2905\"\u003e\u003cstrong data-start=\"2785\" data-end=\"2828\"\u003e4. Can it handle high-power appliances?\u003c\/strong\u003e\u003cbr data-start=\"2828\" data-end=\"2831\"\u003eYes, the 40A MCB allows safe operation of typical garage electrical loads.\u003c\/p\u003e\n\u003cp data-start=\"2907\" data-end=\"3040\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2907\" data-end=\"2949\"\u003e5. Is it suitable for outdoor garages?\u003c\/strong\u003e\u003cbr data-start=\"2949\" data-end=\"2952\"\u003eYes, it is ideal for garage installations when fitted in a suitable protected enclosure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289914614142,"sku":null,"price":104.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EV32MS-small_bc0befe7-2c16-4eab-bf8b-8a519a380d2a.png?v=1776709312"},{"product_id":"5-module-garage-unit-with-63a-type-b-rcd-32a-mcb","title":"5 Module Garage Unit with 63A Type B RCD \u0026 32A MCB","description":"\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69e66ac6-9a24-83ea-8954-2d17747d97ea-3\" data-testid=\"conversation-turn-10\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"a0ccab8d-a912-4802-803f-bd850cd5ac63\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"rzkdgm\" data-start=\"357\" data-end=\"368\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"370\" data-end=\"668\"\u003eThis 5 module garage consumer unit is designed to provide safe, efficient, and reliable electrical distribution for garages, workshops, sheds, and other outbuildings. Equipped with a 63A Type B RCD and a 32A MCB, it ensures strong protection against electrical faults, overloads, and earth leakage.\u003c\/p\u003e\n\u003cp data-start=\"670\" data-end=\"929\"\u003eBuilt under SKU: EV32RB, this compact unit is engineered for modern installations where space efficiency and safety are equally important. It offers dependable circuit control, making it suitable for both domestic and light commercial electrical applications.\u003c\/p\u003e\n\u003chr data-start=\"931\" data-end=\"934\"\u003e\n\u003ch2 data-section-id=\"1usr32o\" data-start=\"936\" data-end=\"972\"\u003eWhy Choose a Garage Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"974\" data-end=\"1199\"\u003eChoosing this garage consumer unit means investing in reliable electrical protection and long-term safety. It is designed to comply with modern wiring standards, ensuring stable and secure power distribution for everyday use.\u003c\/p\u003e\n\u003cp data-start=\"1201\" data-end=\"1444\"\u003eWith its integrated RCD protection and dedicated MCB circuit, this unit helps prevent electrical hazards while maintaining smooth performance. It is an ideal solution for users who require a simple yet effective garage power management system.\u003c\/p\u003e\n\u003chr data-start=\"1446\" data-end=\"1449\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1451\" data-end=\"1466\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1468\" data-end=\"1868\"\u003e\n\u003cli data-section-id=\"1i6vy2l\" data-start=\"1468\" data-end=\"1516\"\u003eCompact 5 module garage consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"1kmsy9w\" data-start=\"1517\" data-end=\"1566\"\u003e63A Type B RCD for enhanced electrical safety\u003c\/li\u003e\n\u003cli data-section-id=\"knppd1\" data-start=\"1567\" data-end=\"1612\"\u003e32A MCB for controlled circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1jlht4f\" data-start=\"1613\" data-end=\"1670\"\u003eProtection against overloads and earth leakage faults\u003c\/li\u003e\n\u003cli data-section-id=\"10b3y2o\" data-start=\"1671\" data-end=\"1717\"\u003eSpace-saving and easy-to-install enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"y29o42\" data-start=\"1718\" data-end=\"1764\"\u003eSuitable for garages, sheds, and workshops\u003c\/li\u003e\n\u003cli data-section-id=\"cqmrlq\" data-start=\"1765\" data-end=\"1815\"\u003eDurable construction for long-term reliability\u003c\/li\u003e\n\u003cli data-section-id=\"172wei5\" data-start=\"1816\" data-end=\"1868\"\u003eComplies with modern electrical safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1870\" data-end=\"1873\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1875\" data-end=\"1902\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1904\" data-end=\"2270\"\u003e\n\u003cli data-section-id=\"wp188e\" data-start=\"1904\" data-end=\"1942\"\u003eProduct Type: Garage Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"15wr6jh\" data-start=\"1943\" data-end=\"1958\"\u003eSKU: EV32RB\u003c\/li\u003e\n\u003cli data-section-id=\"l7q3fo\" data-start=\"1959\" data-end=\"1983\"\u003eNumber of Modules: 5\u003c\/li\u003e\n\u003cli data-section-id=\"1s68qri\" data-start=\"1984\" data-end=\"2010\"\u003eRCD Rating: 63A Type B\u003c\/li\u003e\n\u003cli data-section-id=\"1et3z95\" data-start=\"2011\" data-end=\"2030\"\u003eMCB Rating: 32A\u003c\/li\u003e\n\u003cli data-section-id=\"1ilzr1m\" data-start=\"2031\" data-end=\"2065\"\u003eSurge Protection: Not included\u003c\/li\u003e\n\u003cli data-section-id=\"15c7b1a\" data-start=\"2066\" data-end=\"2100\"\u003eMounting Type: Surface mounted\u003c\/li\u003e\n\u003cli data-section-id=\"g8pbt8\" data-start=\"2101\" data-end=\"2151\"\u003eApplication: Domestic and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"xefxp9\" data-start=\"2152\" data-end=\"2207\"\u003eEnclosure Material: High-strength insulated housing\u003c\/li\u003e\n\u003cli data-section-id=\"lw5t7g\" data-start=\"2208\" data-end=\"2270\"\u003eProtection Features: Overload and earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2272\" data-end=\"2275\"\u003e\n\u003ch2 data-section-id=\"1xvwnkw\" data-start=\"2277\" data-end=\"2284\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2286\" data-end=\"2436\"\u003e\u003cstrong data-start=\"2286\" data-end=\"2342\"\u003e1. What is the purpose of this garage consumer unit?\u003c\/strong\u003e\u003cbr data-start=\"2342\" data-end=\"2345\"\u003eIt provides safe and controlled electrical distribution for garages and external buildings.\u003c\/p\u003e\n\u003cp data-start=\"2438\" data-end=\"2558\"\u003e\u003cstrong data-start=\"2438\" data-end=\"2480\"\u003e2. What protection does the RCD offer?\u003c\/strong\u003e\u003cbr data-start=\"2480\" data-end=\"2483\"\u003eThe 63A Type B RCD protects against earth leakage and electric shock risks.\u003c\/p\u003e\n\u003cp data-start=\"2560\" data-end=\"2660\"\u003e\u003cstrong data-start=\"2560\" data-end=\"2605\"\u003e3. Is a surge protection device included?\u003c\/strong\u003e\u003cbr data-start=\"2605\" data-end=\"2608\"\u003eNo, this model includes RCD and MCB protection only.\u003c\/p\u003e\n\u003cp data-start=\"2662\" data-end=\"2783\"\u003e\u003cstrong data-start=\"2662\" data-end=\"2713\"\u003e4. Can this unit handle heavy garage equipment?\u003c\/strong\u003e\u003cbr data-start=\"2713\" data-end=\"2716\"\u003eYes, the 32A MCB supports typical garage power requirements safely.\u003c\/p\u003e\n\u003cp data-start=\"2785\" data-end=\"2920\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2785\" data-end=\"2832\"\u003e5. Is it suitable for outdoor installation?\u003c\/strong\u003e\u003cbr data-start=\"2832\" data-end=\"2835\"\u003eYes, it is ideal for garages and outbuildings when installed in a suitable enclosure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289922609534,"sku":null,"price":95.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EV32RB-1.png?v=1776709648"},{"product_id":"5-module-garage-unit-with-63a-type-b-rcd-40a-mcb","title":"5 Module Garage Unit with 63A Type B RCD \u0026 40A MCB","description":"\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69e66ac6-9a24-83ea-8954-2d17747d97ea-4\" data-testid=\"conversation-turn-12\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"8a4153ad-593c-4453-8826-2491d4728c9d\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"rzkdgm\" data-start=\"348\" data-end=\"359\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"361\" data-end=\"674\"\u003eThis 5 module garage consumer unit is a reliable and compact electrical distribution solution designed for safe power management in garages, workshops, and external buildings. It is fitted with a 63A Type B RCD and a 40A MCB, offering dependable protection against earth faults, overloads, and electrical hazards.\u003c\/p\u003e\n\u003cp data-start=\"676\" data-end=\"916\"\u003eBuilt under SKU: EV40RB, this unit combines safety and efficiency in a space-saving enclosure. It is ideal for modern electrical installations where secure circuit control and compliance with safety standards are essential for everyday use.\u003c\/p\u003e\n\u003chr data-start=\"918\" data-end=\"921\"\u003e\n\u003ch2 data-section-id=\"1usr32o\" data-start=\"923\" data-end=\"959\"\u003eWhy Choose a Garage Consumer Unit\u003c\/h2\u003e\n\u003cp data-start=\"961\" data-end=\"1191\"\u003eChoosing this garage consumer unit ensures a secure and efficient way to manage electrical circuits in demanding environments. It is engineered to deliver consistent performance while meeting modern electrical safety requirements.\u003c\/p\u003e\n\u003cp data-start=\"1193\" data-end=\"1425\"\u003eWith integrated RCD protection and a dedicated MCB, this unit provides enhanced safety against electrical faults and overloads. It is a practical solution for homeowners and installers looking for reliable garage power distribution.\u003c\/p\u003e\n\u003chr data-start=\"1427\" data-end=\"1430\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1432\" data-end=\"1447\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1449\" data-end=\"1844\"\u003e\n\u003cli data-section-id=\"1i6vy2l\" data-start=\"1449\" data-end=\"1497\"\u003eCompact 5 module garage consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"13nsk2j\" data-start=\"1498\" data-end=\"1551\"\u003e63A Type B RCD for enhanced electrical protection\u003c\/li\u003e\n\u003cli data-section-id=\"18y4ank\" data-start=\"1552\" data-end=\"1597\"\u003e40A MCB for controlled circuit management\u003c\/li\u003e\n\u003cli data-section-id=\"1rc8p86\" data-start=\"1598\" data-end=\"1648\"\u003eProtection against overloads and earth leakage\u003c\/li\u003e\n\u003cli data-section-id=\"192v6er\" data-start=\"1649\" data-end=\"1697\"\u003eSpace-efficient and easy installation design\u003c\/li\u003e\n\u003cli data-section-id=\"y29o42\" data-start=\"1698\" data-end=\"1744\"\u003eSuitable for garages, sheds, and workshops\u003c\/li\u003e\n\u003cli data-section-id=\"1eqojfk\" data-start=\"1745\" data-end=\"1790\"\u003eDurable and robust enclosure construction\u003c\/li\u003e\n\u003cli data-section-id=\"bx2334\" data-start=\"1791\" data-end=\"1844\"\u003eCompliant with modern electrical safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1846\" data-end=\"1849\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1851\" data-end=\"1878\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1880\" data-end=\"2246\"\u003e\n\u003cli data-section-id=\"wp188e\" data-start=\"1880\" data-end=\"1918\"\u003eProduct Type: Garage Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"12qzqm0\" data-start=\"1919\" data-end=\"1934\"\u003eSKU: EV40RB\u003c\/li\u003e\n\u003cli data-section-id=\"l7q3fo\" data-start=\"1935\" data-end=\"1959\"\u003eNumber of Modules: 5\u003c\/li\u003e\n\u003cli data-section-id=\"1s68qri\" data-start=\"1960\" data-end=\"1986\"\u003eRCD Rating: 63A Type B\u003c\/li\u003e\n\u003cli data-section-id=\"1etzdh8\" data-start=\"1987\" data-end=\"2006\"\u003eMCB Rating: 40A\u003c\/li\u003e\n\u003cli data-section-id=\"1ilzr1m\" data-start=\"2007\" data-end=\"2041\"\u003eSurge Protection: Not included\u003c\/li\u003e\n\u003cli data-section-id=\"15c7b1a\" data-start=\"2042\" data-end=\"2076\"\u003eMounting Type: Surface mounted\u003c\/li\u003e\n\u003cli data-section-id=\"g8pbt8\" data-start=\"2077\" data-end=\"2127\"\u003eApplication: Domestic and light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"xefxp9\" data-start=\"2128\" data-end=\"2183\"\u003eEnclosure Material: High-strength insulated housing\u003c\/li\u003e\n\u003cli data-section-id=\"lw5t7g\" data-start=\"2184\" data-end=\"2246\"\u003eProtection Features: Overload and earth leakage protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2248\" data-end=\"2251\"\u003e\n\u003ch2 data-section-id=\"1xvwnkw\" data-start=\"2253\" data-end=\"2260\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2262\" data-end=\"2403\"\u003e\u003cstrong data-start=\"2262\" data-end=\"2312\"\u003e1. What is this garage consumer unit used for?\u003c\/strong\u003e\u003cbr data-start=\"2312\" data-end=\"2315\"\u003eIt is used for safe distribution of electricity in garages, workshops, and outbuildings.\u003c\/p\u003e\n\u003cp data-start=\"2405\" data-end=\"2527\"\u003e\u003cstrong data-start=\"2405\" data-end=\"2449\"\u003e2. What protection does the RCD provide?\u003c\/strong\u003e\u003cbr data-start=\"2449\" data-end=\"2452\"\u003eThe 63A Type B RCD protects against earth leakage and electric shock risks.\u003c\/p\u003e\n\u003cp data-start=\"2529\" data-end=\"2631\"\u003e\u003cstrong data-start=\"2529\" data-end=\"2576\"\u003e3. Does this unit include surge protection?\u003c\/strong\u003e\u003cbr data-start=\"2576\" data-end=\"2579\"\u003eNo, this model includes RCD and MCB protection only.\u003c\/p\u003e\n\u003cp data-start=\"2633\" data-end=\"2738\"\u003e\u003cstrong data-start=\"2633\" data-end=\"2672\"\u003e4. Can it support high-power tools?\u003c\/strong\u003e\u003cbr data-start=\"2672\" data-end=\"2675\"\u003eYes, the 40A MCB supports most typical garage equipment safely.\u003c\/p\u003e\n\u003cp data-start=\"2740\" data-end=\"2862\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2740\" data-end=\"2778\"\u003e5. Is it suitable for outdoor use?\u003c\/strong\u003e\u003cbr data-start=\"2778\" data-end=\"2781\"\u003eYes, it is suitable for garage and external installations when properly enclosed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289927262590,"sku":null,"price":95.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EV32RB.png?v=1776709953"},{"product_id":"6-module-board-with-40a-rcbo-energy-meter-100a-main-switch-spd","title":"6 Module Board with 40A RCBO, Energy Meter, 100A Main Switch \u0026 SPD","description":"\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-69e66ac6-9a24-83ea-8954-2d17747d97ea-5\" data-testid=\"conversation-turn-14\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"746bd181-caf2-4186-9b78-75cc02b3f184\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"rzkdgm\" data-start=\"395\" data-end=\"406\"\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"408\" data-end=\"763\"\u003eThis 6 module consumer unit is a high-performance electrical distribution board designed for advanced safety, monitoring, and efficient power management. It integrates a 40A bi-directional RCBO, an energy meter, a 100A main switch, and surge protection device (SPD), making it a complete solution for modern residential and light commercial installations.\u003c\/p\u003e\n\u003cp data-start=\"765\" data-end=\"1063\"\u003eBuilt under SKU EV40MSE, this unit offers enhanced control and real-time energy monitoring while ensuring full protection against overloads, short circuits, and voltage surges. Its compact 6-module layout makes it ideal for installations where both functionality and space efficiency are essential.\u003c\/p\u003e\n\u003chr data-start=\"1065\" data-end=\"1068\"\u003e\n\u003ch2 data-section-id=\"13f6nj6\" data-start=\"1070\" data-end=\"1119\"\u003eWhy Choose a 6 Module Consumer Unit with Meter\u003c\/h2\u003e\n\u003cp data-start=\"1121\" data-end=\"1352\"\u003eChoosing this 6 module board ensures a smarter and safer approach to electrical distribution. It is designed to meet modern wiring standards while offering integrated energy monitoring for better power usage control and efficiency.\u003c\/p\u003e\n\u003cp data-start=\"1354\" data-end=\"1625\"\u003eWith built-in RCBO protection, SPD safety features, and a powerful main isolator switch, this unit delivers dependable performance and peace of mind. It is an excellent choice for installations requiring both advanced protection and energy tracking in one compact system.\u003c\/p\u003e\n\u003chr data-start=\"1627\" data-end=\"1630\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1632\" data-end=\"1647\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1649\" data-end=\"2038\"\u003e\n\u003cli data-section-id=\"2t8ill\" data-start=\"1649\" data-end=\"1690\"\u003e6 module compact consumer unit design\u003c\/li\u003e\n\u003cli data-section-id=\"z5p457\" data-start=\"1691\" data-end=\"1738\"\u003e40A bi-directional RCBO for dual protection\u003c\/li\u003e\n\u003cli data-section-id=\"c63eeb\" data-start=\"1739\" data-end=\"1791\"\u003eIntegrated energy meter for real-time monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"e3pd5a\" data-start=\"1792\" data-end=\"1843\"\u003e100A double pole main switch for full isolation\u003c\/li\u003e\n\u003cli data-section-id=\"10e00a7\" data-start=\"1844\" data-end=\"1886\"\u003eBuilt-in surge protection device (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"1x3vljf\" data-start=\"1887\" data-end=\"1941\"\u003eProtection against overloads and electrical faults\u003c\/li\u003e\n\u003cli data-section-id=\"1qvhrfq\" data-start=\"1942\" data-end=\"1987\"\u003eSpace-saving and easy installation layout\u003c\/li\u003e\n\u003cli data-section-id=\"j73d46\" data-start=\"1988\" data-end=\"2038\"\u003eSuitable for domestic and light commercial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2040\" data-end=\"2043\"\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"2045\" data-end=\"2072\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"2074\" data-end=\"2456\"\u003e\n\u003cli data-section-id=\"1o8prf9\" data-start=\"2074\" data-end=\"2114\"\u003eProduct Type: 6 Module Consumer Unit\u003c\/li\u003e\n\u003cli data-section-id=\"1ythfmb\" data-start=\"2115\" data-end=\"2131\"\u003eSKU: EV40MSE\u003c\/li\u003e\n\u003cli data-section-id=\"fajvxe\" data-start=\"2132\" data-end=\"2167\"\u003eRCBO Rating: 40A Bi-directional\u003c\/li\u003e\n\u003cli data-section-id=\"12ko4qk\" data-start=\"2168\" data-end=\"2196\"\u003eMain Switch Rating: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"10eoyvu\" data-start=\"2197\" data-end=\"2244\"\u003eEnergy Meter: Integrated digital monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"gaggyg\" data-start=\"2245\" data-end=\"2279\"\u003eSurge Protection: SPD included\u003c\/li\u003e\n\u003cli data-section-id=\"l7q7l3\" data-start=\"2280\" data-end=\"2304\"\u003eNumber of Modules: 6\u003c\/li\u003e\n\u003cli data-section-id=\"15c7b1a\" data-start=\"2305\" data-end=\"2339\"\u003eMounting Type: Surface mounted\u003c\/li\u003e\n\u003cli data-section-id=\"q8dxi9\" data-start=\"2340\" data-end=\"2388\"\u003eApplication: Domestic \u0026amp; light commercial use\u003c\/li\u003e\n\u003cli data-section-id=\"p1lxc\" data-start=\"2389\" data-end=\"2456\"\u003eProtection Features: Overload, short circuit \u0026amp; surge protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2458\" data-end=\"2461\"\u003e\n\u003ch2 data-section-id=\"1xvwnkw\" data-start=\"2463\" data-end=\"2470\"\u003eFAQs\u003c\/h2\u003e\n\u003cp data-start=\"2472\" data-end=\"2622\"\u003e\u003cstrong data-start=\"2472\" data-end=\"2522\"\u003e1. What is the purpose of this 6 module board?\u003c\/strong\u003e\u003cbr data-start=\"2522\" data-end=\"2525\"\u003eIt is used for safe electrical distribution with added energy monitoring and protection features.\u003c\/p\u003e\n\u003cp data-start=\"2624\" data-end=\"2746\"\u003e\u003cstrong data-start=\"2624\" data-end=\"2661\"\u003e2. What does the energy meter do?\u003c\/strong\u003e\u003cbr data-start=\"2661\" data-end=\"2664\"\u003eIt tracks real-time electricity usage for better energy management and efficiency.\u003c\/p\u003e\n\u003cp data-start=\"2748\" data-end=\"2884\"\u003e\u003cstrong data-start=\"2748\" data-end=\"2799\"\u003e3. Does this unit protect against power surges?\u003c\/strong\u003e\u003cbr data-start=\"2799\" data-end=\"2802\"\u003eYes, it includes a built-in SPD to protect connected circuits from voltage spikes.\u003c\/p\u003e\n\u003cp data-start=\"2886\" data-end=\"3015\"\u003e\u003cstrong data-start=\"2886\" data-end=\"2932\"\u003e4. What is a bi-directional RCBO used for?\u003c\/strong\u003e\u003cbr data-start=\"2932\" data-end=\"2935\"\u003eIt provides both overload and earth leakage protection in both power directions.\u003c\/p\u003e\n\u003cp data-start=\"3017\" data-end=\"3151\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"3017\" data-end=\"3070\"\u003e5. Is this suitable for commercial installations?\u003c\/strong\u003e\u003cbr data-start=\"3070\" data-end=\"3073\"\u003eYes, it is suitable for both domestic and light commercial electrical systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57289936699774,"sku":null,"price":56.16,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/EV40MS-G-2_4f1b302c-e59e-461a-a150-c0dda47de893.png?v=1776710270"},{"product_id":"dual-protection-powerhouse-6ka-6a-rcbo-with-30ma-type-a-rcd","title":"Dual Protection Powerhouse: 6kA 6A RCBO with 30mA Type A RCD","description":"\u003cdiv class=\"ds-message _63c77b1\"\u003e\n\u003cdiv class=\"ds-markdown\"\u003e\n\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe 6kA 6A RCBO (Residual Current Breaker with Overcurrent) represents the pinnacle of electrical safety integration, combining the functions of a miniature circuit breaker and a residual current device into a single, space-saving 1-module unit. With a 6-ampere rated current, this RCBO is specifically engineered for protecting dedicated lighting circuits, sensitive electronic equipment, smoke alarm systems, fire alarm panels, small control circuits, and other low-current applications where both overcurrent protection and earth leakage detection are critical. The device delivers 6kA short-circuit breaking capacity (Icn) with an impressive 7.5kA service breaking capacity (Ics), ensuring reliable fault clearing even under demanding conditions while maintaining operational integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eManufactured to comply with IEC\/EN61009-1 standards, this Type A RCBO provides 30mA residual current protection specifically designed to detect both sinusoidal AC leakage and pulsating DC leakage currents—making it essential for circuits powering modern electronics, computers, appliances with switch-mode power supplies, and equipment containing single-phase rectified circuits. The Type A characteristic offers superior protection compared to basic AC-type RCDs, which only detect sinusoidal leakage currents. With B-curve magnetic tripping characteristics (3-5x rated current), this RCBO is ideally suited for resistive and lightly inductive loads where nuisance tripping must be minimized. The device supports 230\/240VAC single-phase systems, operates at 50\/60Hz, and features pillar-type terminals accepting up to 25mm² cable, making it a comprehensive protection solution for residential, commercial, and industrial applications requiring the highest standards of electrical safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eUltimate Integrated Safety for Sensitive Low-Current Circuits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe 6A RCBO addresses a critical gap in electrical protection that standard MCBs or standalone RCDs cannot individually provide. While a conventional MCB protects only against overcurrent and short circuits, and a separate RCD only detects earth leakage, this integrated RCBO delivers both protection mechanisms simultaneously within a single 1-module DIN rail footprint. This integration is particularly valuable for dedicated lighting circuits where earth leakage from moisture ingress or damaged insulation could create shock hazards without tripping the overcurrent protection. The 6-ampere rating makes this RCBO perfect for lighting circuits with LED or fluorescent fittings (which can generate harmonic currents that standard AC-type RCDs may not detect properly), smoke alarm interconnects, fire alarm field loops, intruder alarm systems, door entry systems, small pump control circuits, and sensitive electronic equipment requiring both fault current and earth leakage protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFurthermore, the Type A residual current characteristic sets this RCBO apart from basic AC-type protection devices. Standard AC-type RCDs only detect smooth sinusoidal AC leakage currents—adequate for pure resistive or inductive loads but increasingly inadequate for modern electrical installations containing switch-mode power supplies, variable speed drives, induction cooktops, washing machines, dishwashers, EV chargers, and other electronics that generate pulsating DC leakage currents. The Type A rating detects both AC sinusoidal and pulsating DC residual currents, providing comprehensive protection for contemporary electrical systems. With 30mA sensitivity—the standard for personnel protection against electric shock—this RCBO will trip within milliseconds when leakage current exceeds 30mA, long before ventricular fibrillation can occur. The mechanical endurance rating of 30,000 operations and electrical endurance of 10,000 cycles ensures long-term reliability, while the operating temperature range of -5°C to +55°C accommodates most indoor installation environments. For any low-current circuit where both overcurrent protection and advanced earth leakage detection are required, this 6A Type A RCBO delivers uncompromising safety in a compact, space-saving package.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDual Protection Integration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Combines MCB overcurrent protection and RCD earth leakage protection in a single 1-module unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e6kA Breaking Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Provides Icn=6kA and Ics=7.5kA short-circuit interruption for superior fault clearing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType A Residual Current Detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Detects both sinusoidal AC and pulsating DC leakage currents for modern electronic loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e30mA Personnel Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Standard sensitivity for electric shock protection, tripping within milliseconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eB-Curve Magnetic Trip\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 3-5x rated current (18-30A) tripping characteristic ideal for lighting and resistive loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSingle-Pole Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 1P design with 1 module width for space-saving DIN rail installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Cycle Life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Rated for 30,000 mechanical operations and 10,000 electrical operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Cable Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Pillar terminals accept up to 25mm² conductors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIP20 Protection Rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Suitable for installation within consumer units and distribution boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Temperature Range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Operates from -5°C to +55°C, stores from -25°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Strength\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 2500V insulation withstand for enhanced safety\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTop Supply Only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Designated power supply orientation for correct operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e RCBO (Residual Current Breaker with Overcurrent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 6 Amperes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Poles:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1P (1 module width)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230\/240VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eShort-Circuit Breaking Capacity (Icn):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 6kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eService Breaking Capacity (Ics):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 7.5kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMagnetic Tripping Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e B Curve (3-5x In)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eResidual Tripping Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Type A (AC sinusoidal + pulsating DC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Residual Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMechanical Endurance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Endurance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFrequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Strength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2500V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply Orientation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Top supply only (UP)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Pillar type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Cable Termination:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25mm²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eScrew Torque:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.5 Nm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection Grade:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -5°C to +55°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStorage Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -25°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandards Compliance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IEC\/EN61009-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. What is the difference between this RCBO and using a separate MCB plus RCD?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAn RCBO combines both overcurrent protection (MCB function) and earth leakage protection (RCD function) in a single 1-module device. Using separate MCB and RCD requires at least 2 modules (1 for MCB + 2 or 4 for RCD) and provides only shared RCD protection across multiple circuits. An RCBO provides dedicated, independent protection for each circuit—meaning a fault on one circuit doesn't take out other circuits. This RCBO also offers better discrimination and easier fault finding.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. Why do I need Type A residual protection instead of standard AC type?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eStandard AC-type RCDs only detect smooth sinusoidal AC leakage currents. Modern appliances contain switch-mode power supplies, rectifiers, and electronic controls that can produce pulsating DC leakage currents. AC-type RCDs may become desensitized or fail to detect these pulsating DC waveforms. Type A RCBOs detect both AC sinusoidal and pulsating DC leakage, making them essential for circuits powering computers, LED lighting, induction cooktops, washing machines, dishwashers, EV chargers, and any equipment with electronic power supplies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. What applications are suitable for a 6A RCBO with B-curve characteristic?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA 6A B-curve RCBO is ideal for lighting circuits (LED, fluorescent, or incandescent), smoke alarm interconnects, fire alarm systems, intruder alarms, door entry systems, CCTV power supplies, control circuits, small pumps, ventilation fans, and any circuit with resistive or lightly inductive loads where inrush current is minimal. The B-curve (3-5x rated current) trips between 18-30A, preventing nuisance tripping while providing adequate protection for these sensitive low-current circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. What is the significance of Ics=7.5kA being higher than Icn=6kA?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIcn (6kA) is the rated short-circuit breaking capacity—the fault current the RCBO can interrupt once and remain safe. Ics (7.5kA) is the service short-circuit breaking capacity—the fault current the RCBO can interrupt and still remain fully functional for continued service. Having Ics higher than Icn is exceptional, meaning this RCBO can clear a 7.5kA fault and continue operating normally, whereas most breakers require replacement after clearing a fault at their Icn rating. This provides superior reliability and reduced maintenance costs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. Can I use this 6A RCBO on a circuit with a 6A load and 30mA leakage?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eYes and no. The 6A rating handles continuous loads up to 6A (or 4.8A for continuous loads over 3 hours per derating rules). However, the 30mA residual rating means the RCBO will trip when leakage current exceeds 30mA—this is correct for personnel protection. If your equipment has normal leakage near 30mA, you may experience nuisance tripping. Most appliances have normal leakage below 10mA. For circuits with high inherent leakage (long cable runs or multiple devices), consider a 100mA time-delayed RCD upstream for selectivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57290179608958,"sku":null,"price":9.56,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/Untitled-design-94.png?v=1776714721"},{"product_id":"complete-circuit-safety-6ka-10a-rcbo-with-type-a-30ma-protection","title":"Complete Circuit Safety: 6kA 10A RCBO with Type A 30mA Protection","description":"\u003cdiv class=\"ds-message _63c77b1\"\u003e\n\u003cdiv class=\"ds-markdown\"\u003e\n\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe 6kA 10A RCBO (Residual Current Breaker with Overcurrent) delivers comprehensive circuit protection by integrating both overcurrent and earth leakage safety functions into a single, space-efficient 1-module unit. With a 10-ampere rated current, this RCBO is ideally suited for protecting general purpose socket outlets, lighting circuits, small appliance circuits, office equipment, IT infrastructure, vending machines, commercial display units, and other medium low-current applications requiring both short-circuit\/overload protection and residual current detection. The device delivers 6kA rated short-circuit breaking capacity (Icn) with an exceptional 7.5kA service breaking capacity (Ics), ensuring reliable fault clearing under demanding conditions while maintaining full operational integrity for continued service after fault interruption.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eManufactured in strict compliance with IEC\/EN61009-1 standards, this Type A RCBO provides 30mA residual current protection specifically engineered to detect both conventional sinusoidal AC leakage and the pulsating DC leakage currents generated by modern electronic equipment. The Type A characteristic offers superior protection compared to basic AC-type RCDs, making it essential for circuits powering computers, printers, LED lighting, variable speed drives, induction appliances, and any device with switch-mode power supplies or single-phase rectified circuits. With B-curve magnetic tripping characteristics (3-5x rated current = 30-50A trip range), this RCBO is perfectly calibrated for resistive and lightly inductive loads where nuisance tripping must be minimized while maintaining rapid fault clearance. Operating on 230\/240VAC single-phase systems at 50\/60Hz, featuring pillar-type terminals accepting up to 25mm² cable, and rated for 30,000 mechanical operations, this 10A RCBO represents the ideal protection solution for residential socket circuits, commercial office environments, and light industrial applications demanding the highest standards of integrated electrical safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSuperior Integrated Protection for General Purpose Circuits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe 10A RCBO addresses a critical protection gap that separate MCBs and RCDs cannot effectively bridge. While a conventional MCB protects only against overcurrent and short circuits, and a standalone RCD provides only earth leakage detection, this integrated RCBO delivers both protection mechanisms simultaneously within a single 1-module DIN rail footprint—saving valuable space in consumer units and distribution boards. This integration is particularly valuable for general purpose socket circuits where portable appliances with unknown leakage characteristics may be connected, or for mixed-use circuits containing both traditional resistive loads and modern electronic equipment. The 10-ampere rating makes this RCBO perfect for ring or radial socket circuits protecting multiple general use outlets (maximum 10A per socket or 13A per BS1363 outlet, but circuit protection at 10A provides enhanced safety for dedicated appliance circuits), lighting circuits with moderate LED\/CFL loads, office workstations with computers and peripherals, small kitchen appliances, vending machines, commercial display cases, IT rack power distribution, and any circuit where both fault current protection and earth leakage detection are required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFurthermore, the Type A residual current characteristic elevates this RCBO above basic AC-type protection devices that are increasingly inadequate for modern electrical installations. Standard AC-type RCDs detect only smooth sinusoidal AC leakage currents—adequate for pure resistive loads like incandescent lighting or simple heating elements but dangerously ineffective for contemporary loads containing switch-mode power supplies. Modern equipment including computers, monitors, printers, LED drivers, induction hobs, washing machines, dishwashers, EV chargers, and variable frequency drives all generate pulsating DC leakage currents that can desensitize AC-type RCDs, causing them to fail to trip when dangerous leakage occurs. The Type A rating detects both AC sinusoidal and pulsating DC residual currents, providing comprehensive protection for today's mixed-technology electrical systems. With 30mA sensitivity—the internationally recognized standard for personnel protection against electric shock—this RCBO will trip within milliseconds (typically less than 40ms at 5x IΔn) when leakage current exceeds 30mA, long before ventricular fibrillation can occur. The mechanical endurance rating of 30,000 operations ensures long-term reliability for frequently switched circuits, while the electrical endurance of 10,000 cycles provides confidence for permanent installations. The operating temperature range of -5°C to +55°C accommodates most indoor installation environments from residential consumer units to commercial distribution boards. For any 10A-rated general purpose circuit where both overcurrent protection and advanced earth leakage detection are required, this Type A RCBO delivers uncompromising integrated safety in a compact, space-saving 1-module package.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComplete 2-in-1 Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Integrates MCB overcurrent protection and RCD earth leakage protection in a single 1-module unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSuperior Breaking Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Provides Icn=6kA and Ics=7.5kA (Ics higher than Icn for enhanced reliability)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eType A Residual Current Detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Detects both sinusoidal AC and pulsating DC leakage currents for modern electronic loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e30mA Personnel Protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Standard sensitivity for electric shock protection with millisecond trip response\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eB-Curve Magnetic Trip\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 3-5x rated current (30-50A) tripping characteristic ideal for general purpose socket and lighting circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSingle-Pole Compact Design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 1P configuration with 1 module width for space-saving DIN rail installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eExceptional Cycle Life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Rated for 30,000 mechanical operations and 10,000 electrical operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eGenerous Cable Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Pillar terminals accept up to 25mm² conductors for flexible installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIP20 Protection Rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Suitable for installation within consumer units, distribution boards, and enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Functions reliably from -5°C to +55°C, stores from -25°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Dielectric Strength\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 2500V insulation withstand for enhanced electrical safety\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTop Supply Orientation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Designated power supply direction for correct and safe operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e RCBO (Residual Current Breaker with Overcurrent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10 Amperes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Poles:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1P (1 module width)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230\/240VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eShort-Circuit Breaking Capacity (Icn):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 6kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eService Breaking Capacity (Ics):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 7.5kA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMagnetic Tripping Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e B Curve (3-5x In = 30-50A trip range)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eResidual Tripping Characteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Type A (AC sinusoidal + pulsating DC detection)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRated Residual Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMechanical Endurance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Endurance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10,000 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFrequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDielectric Strength:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2500V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply Orientation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Top supply only (UP)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminal Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Pillar type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Cable Termination:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25mm²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eScrew Torque:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2.5 Nm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProtection Grade:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -5°C to +55°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStorage Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -25°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandards Compliance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e IEC\/EN61009-1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. What circuits are typically protected by a 10A RCBO with B-curve characteristic?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA 10A B-curve RCBO is ideal for general purpose socket outlets (individual or small groups), dedicated appliance circuits for fridges, freezers, microwaves, or washing machines, lighting circuits with multiple LED\/CFL fittings, office equipment circuits (computers, printers, copiers), IT and data centre power distribution, vending machines, commercial display units, small pumps and fans, and any circuit with mixed resistive and electronic loads where inrush current is moderate and nuisance tripping must be minimized.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. Why is Type A protection necessary rather than basic AC-type for a 10A circuit?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eBasic AC-type RCDs only detect smooth sinusoidal AC leakage currents and can become desensitized by pulsating DC leakage. Modern 10A circuits typically power equipment containing switch-mode power supplies (computers, monitors, LED drivers, phone chargers, appliances with electronic controls) which generate pulsating DC leakage. Type A RCBOs detect both AC sinusoidal and pulsating DC waveforms, ensuring continued protection as circuits are upgraded with modern electronic loads. Many wiring regulations now require Type A for socket circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. Can I replace an existing 10A MCB with this 10A RCBO without changing my consumer unit?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIn most cases yes, provided your consumer unit accepts 1-module wide devices on a standard 35mm DIN rail and has a neutral bar for the RCBO's flying neutral lead. Unlike an MCB which requires only a line connection, an RCBO requires both line and neutral connections. You will need to connect the line terminal to the busbar, the neutral flying lead to the neutral bar, and ensure the circuit's neutral conductor is correctly connected to the RCBO. Always isolate the consumer unit before any replacement and verify compatibility with your specific distribution board.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. What does Ics=7.5kA being higher than Icn=6kA mean for my installation?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIcn (6kA) is the rated short-circuit breaking capacity—the fault current the RCBO can interrupt once and remain safe for use. Ics (7.5kA) is the service short-circuit breaking capacity—the fault current the RCBO can interrupt and still remain fully functional for continued normal service. Having Ics higher than Icn is an exceptional reliability feature, meaning if this RCBO clears a fault up to 7.5kA, it will continue operating correctly without needing replacement. Most standard breakers require replacement after clearing any fault at their Icn rating. This provides superior reliability and reduced maintenance costs for commercial and industrial installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. What is the maximum cable length for a 10A circuit protected by this RCBO?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe maximum cable length depends on conductor size, installation method, and acceptable voltage drop (3% for lighting, 5% for power per BS 7671). For a 10A circuit using 1.5mm² cable (typical for lighting): maximum length approximately 45 metres for 3% drop or 75 metres for 5% drop. For 2.5mm² cable (typical for socket circuits): approximately 75 metres for 3% drop or 125 metres for 5% drop. Longer runs require larger cable sizes (4mm² or 6mm²) to maintain voltage drop limits and ensure adequate fault current for rapid tripping. Always calculate based on your specific installation conditions and regulatory requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Excel","offers":[{"title":"Default Title","offer_id":57290235773310,"sku":null,"price":9.56,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/Untitled-design-94_098b59db-0cfe-4624-98b8-2fb97ea1534a.png?v=1776715844"}],"url":"https:\/\/ssmelectric.co.uk\/collections\/rcbos.oembed?page=7","provider":"SSM ELECTRIC","version":"1.0","type":"link"}