{"title":"C-Tec","description":"","products":[{"product_id":"c-tec-cfp702e-4-cfp-economy-2-zone-conventional-fire-alarm-panel","title":"C-Tec CFP702E-4 CFP Economy 2 Zone Conventional Fire Alarm Panel","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eC-Tec CFP702E-4 CFP Economy 2 Zone Conventional Fire Alarm Panel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a cost-effective, fully certified fire detection solution ideal for small to medium-sized installations. LPCB certified to EN54-2 and EN54-4 standards, this panel offers a comprehensive array of user and installer-friendly features at a competitive price point. Housed in an attractive flush or surface-mountable plastic enclosure, it provides two detector zones and four conventional sounder circuits, making it suitable for shops, offices, and communal areas. The intuitive interface features colour-coded buttons and combined keypad\/keyswitch entry for secure and straightforward operation. With four open-collector outputs and class change\/alert inputs, it delivers flexibility while maintaining simplicity. Note that this economy version has limited engineering functions and is not compatible with expansion boards or repeaters, making it a straightforward, no-frills solution for basic fire alarm requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features of C-Tec CFP702E-4 2 Zone Fire Alarm Panel\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLPCB Certified to EN54-2 \u0026amp; EN54-4:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Third-party certified by the Loss Prevention Certification Board for assured quality and compliance \u003c\/span\u003e\u003ca href=\"https:\/\/www.acornfiresecurity.com\/c-tec-economy-cfp-conventional-fire-panel?srsltid=AfmBOoo5oftxGxzOO85WRgHaqPrxEbokN_cwDaqT2W4Q33qI8UXFH6PT\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/jkfire.in\/product\/c-tec-economy-cfp-2-zone-conventional-fire-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTwo Detector Zones:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports up to 25 detectors per zone (or 32 combined detectors\/call points) with a maximum cable length of 500m per circuit \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFour Conventional Sounder Circuits:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides up to 800mA total output current (4 x 200mA) for alarm devices \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIntuitive User Interface:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Colour-coded buttons and combined keypad\/keyswitch entry for straightforward user and engineer access \u003c\/span\u003e\u003ca href=\"https:\/\/www.acornfiresecurity.com\/c-tec-economy-cfp-conventional-fire-panel?srsltid=AfmBOoo5oftxGxzOO85WRgHaqPrxEbokN_cwDaqT2W4Q33qI8UXFH6PT\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/jkfire.in\/product\/c-tec-economy-cfp-2-zone-conventional-fire-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIntegral 1.5A Power Supply:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EN54-4\/A2 compliant switch-mode PSU with support for up to 2 x 12V 3.2Ah VRLA batteries \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFour Open-Collector Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes Fire, Fault, Reset, and Remote outputs (30mA max sink current) \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAuxiliary Inputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 'Class change' and 'Alert' inputs for external system control \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFlush or Surface Mountable:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supplied in an attractive plastic enclosure with no bezel required for a clean finish \u003c\/span\u003e\u003ca href=\"https:\/\/www.acornfiresecurity.com\/c-tec-economy-cfp-conventional-fire-panel?srsltid=AfmBOoo5oftxGxzOO85WRgHaqPrxEbokN_cwDaqT2W4Q33qI8UXFH6PT\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLow Quiescent Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Only 25mA consumption in standby mode \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eUK Manufactured:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built by C-TEC in the UK \u003c\/span\u003e\u003ca href=\"https:\/\/jkfire.in\/product\/c-tec-economy-cfp-2-zone-conventional-fire-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFully Compatible:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Works seamlessly with C-TEC's ActiV range of conventional fire detectors \u003c\/span\u003e\u003ca href=\"https:\/\/www.acornfiresecurity.com\/c-tec-economy-cfp-conventional-fire-panel?srsltid=AfmBOoo5oftxGxzOO85WRgHaqPrxEbokN_cwDaqT2W4Q33qI8UXFH6PT\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC-Tec\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCFP702E-4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Zone Conventional Fire Alarm Panel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eLPCB certified to EN54-2 \u0026amp; EN54-4 \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMains Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e230V 50\/60Hz (350mA max) \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInternal PSU\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e19V-28.5V (27V nominal), 1.5A total output \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eQuiescent Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e25mA \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMax Battery Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e2 x 12V 3.2Ah VRLA \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDetector Zones\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e2 (Max 500m per circuit) \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDevices per Zone\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e25 detectors (or 32 combined detectors\/call points) \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSounder Circuits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e4 (Max 500m per circuit) \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSounder Output Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e4 x 200mA (800mA total) \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEOL Resistor Value\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e6800Ω (detector zone) \/ 6800Ω (sounder circuit) \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOpen Collector Outputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e4 (Fire, Fault, Reset, Remote) \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuxiliary Inputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eClass Change, Alert \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eExpansion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eNone (not compatible with repeaters or relay cards) \u003c\/span\u003e\u003ca href=\"https:\/\/www.acornfiresecurity.com\/c-tec-economy-cfp-conventional-fire-panel?srsltid=AfmBOoo5oftxGxzOO85WRgHaqPrxEbokN_cwDaqT2W4Q33qI8UXFH6PT\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDimensions (HxWxD)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e380mm x 235mm x 96mm \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlush or Surface mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e1.75kg (without batteries) \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eIP30 \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e-5°C to +40°C \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch1 class=\"product-name\"\u003eFire Alarm\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions (FAQs)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. What is the main difference between this 'Economy' panel and the 'Standard' CFP panel?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe Economy panel (CFP702E-4) has limited engineering functions and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecannot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e be expanded with CFP repeaters, relay cards, or EN54-13 interface cards, unlike the Standard version \u003c\/span\u003e\u003ca href=\"https:\/\/www.acornfiresecurity.com\/c-tec-economy-cfp-conventional-fire-panel?srsltid=AfmBOoo5oftxGxzOO85WRgHaqPrxEbokN_cwDaqT2W4Q33qI8UXFH6PT\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/securitywarehouse.co.uk\/catalog\/fire-c-38\/panels-c-38_48\/ctec-cfp702e4-economy-2-zone-conventional-fire-panel-p-1303.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. How many detectors can I connect to this 2-zone panel?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eYou can connect up to 25 detectors per zone, or a combined total of 32 detectors and manual call points per zone, allowing for a maximum of 64 devices across both zones \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. What size batteries does this panel support?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe panel supports up to two 12V 3.2Ah VRLA batteries connected in series, which fit within the enclosure. The minimum recommended battery size is 1.2Ah \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. Can I mount this panel flush into a wall?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eYes, the panel is supplied in an attractive enclosure suitable for both surface and flush mounting. For flush mounting, a hole of 367mm (W) x 220mm (H) x 75mm (D) is required \u003c\/span\u003e\u003ca href=\"https:\/\/sesco.ie\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/ibm-digitaltwin-embedded.partcommunity.com\/3d-cad-models\/sso\/cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4-cfp-economy-2-zone-conventional-fire-alarm-panel-cfp702e-4-c-tec?info=c_tec%2Fconventional20fire20systems%2Fcfp202-820zone20fire20panels%2Fcfp20economy20220zone20conventional20fire20alarm20panel20cfp702e-420cfp20economy20220zone20conventional20fire20alarm20panel20cfp702e-4.prj\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. Is this panel compatible with third-party detectors?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eWhile it is fully compatible with C-TEC's ActiV range \u003c\/span\u003e\u003ca href=\"https:\/\/www.acornfiresecurity.com\/c-tec-economy-cfp-conventional-fire-panel?srsltid=AfmBOoo5oftxGxzOO85WRgHaqPrxEbokN_cwDaqT2W4Q33qI8UXFH6PT\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e, for compliance and reliable operation, it is always recommended to use detectors specified by the manufacturer or consult the installation manual.\u003c\/span\u003e\u003c\/p\u003e","brand":"C-Tec","offers":[{"title":"Default Title","offer_id":57077106246014,"sku":null,"price":108.86,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/CFP702E-4.webp?v=1773251653"},{"product_id":"c-tec-cfp704e-4-cfp-economy-4-zone-conventional-fire-alarm-panel","title":"C-Tec CFP704E-4 CFP Economy 4 Zone Conventional Fire Alarm Panel","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eC-Tec CFP704E-4 CFP Economy 4 Zone Conventional Fire Alarm Panel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a cost-effective, fully certified fire detection solution ideal for medium-sized installations requiring additional zone capacity. LPCB certified to EN54-2 and EN54-4 standards, this panel offers comprehensive features at a competitive price point. Housed in an attractive flush or surface-mountable plastic enclosure, it provides four detector zones and four conventional sounder circuits, making it suitable for schools, small hotels, offices, and multiple-occupancy buildings. The intuitive interface features colour-coded buttons and combined keypad\/keyswitch entry for secure and straightforward operation. With four open-collector outputs and class change\/alert inputs, it delivers flexibility while maintaining simplicity. Note that this economy version has limited engineering functions and is not compatible with expansion boards or repeaters, making it a straightforward, no-frills solution for basic fire alarm requirements where four-zone coverage is needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features of C-Tec CFP704E-4 4 Zone Fire Alarm Panel\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLPCB Certified to EN54-2 \u0026amp; EN54-4:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Third-party certified by the Loss Prevention Certification Board for assured quality and compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFour Detector Zones:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports up to 25 detectors per zone (or 32 combined detectors\/call points) with maximum 500m cable length per circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFour Conventional Sounder Circuits:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides up to 800mA total output current (4 x 200mA) for alarm devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIntuitive User Interface:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Colour-coded buttons and combined keypad\/keyswitch entry for straightforward user and engineer access.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIntegral Power Supply:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EN54-4\/A2 compliant switch-mode PSU with support for up to 2 x 12V 3.2Ah VRLA batteries.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFour Open-Collector Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes Fire, Fault, Reset, and Remote outputs (30mA max sink current).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAuxiliary Inputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 'Class change' and 'Alert' inputs for external system control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFlush or Surface Mountable:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supplied in attractive plastic enclosure with no bezel required for clean finish.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLow Quiescent Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Energy-efficient standby operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eUK Manufactured:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built by C-TEC in the UK.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eZone Expansion:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Four zones provide increased coverage over 2-zone models.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFully Compatible:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Works seamlessly with C-TEC's ActiV range of conventional fire detectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC-Tec\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCFP704E-4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Zone Conventional Fire Alarm Panel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLPCB certified to EN54-2 \u0026amp; EN54-4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMains Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230V 50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDetector Zones\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (Max 500m per circuit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDevices per Zone\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 detectors (or 32 combined detectors\/call points)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSounder Circuits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (Max 500m per circuit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSounder Output Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 x 200mA (800mA total)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEOL Resistor Value\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6800Ω (detector zone) \/ 6800Ω (sounder circuit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOpen Collector Outputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (Fire, Fault, Reset, Remote)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuxiliary Inputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass Change, Alert\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMax Battery Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 12V 3.2Ah VRLA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eExpansion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (not compatible with repeaters or relay cards)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380mm x 235mm x 96mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlush or Surface mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-5°C to +40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer guarantee\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions (FAQs)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. What is the advantage of choosing the 4-zone model over the 2-zone version?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe 4-zone model (CFP704E-4) provides double the zone capacity, allowing coverage of larger premises or more distinct fire compartments such as separate wings in a school, multiple floors in a hotel, or different occupancy areas.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. How many total devices can be connected across all four zones?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eEach zone supports up to 25 detectors or 32 combined detectors and call points, allowing for a maximum of 100 detectors or 128 combined devices across all four zones, depending on configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. Can this panel be expanded with additional relay outputs or repeaters?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eNo, this Economy model has limited engineering functions and is NOT compatible with CFP repeaters, relay expansion boards, or EN54-13 interface cards. It is designed as a standalone solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. Is the panel suitable for schools or small hotel applications?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eYes, with four zones and four sounder circuits, it is ideal for small to medium schools, hotels, offices, and similar premises requiring multiple detection zones and reliable fire alarm coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. What is the maximum cable length per detector zone?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eEach detector zone supports a maximum cable length of 500 metres, providing flexibility for larger buildings while maintaining reliable communication with all connected devices.\u003c\/span\u003e\u003c\/p\u003e","brand":"C-Tec","offers":[{"title":"Default Title","offer_id":57077127086462,"sku":null,"price":123.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/CFP704E-4.webp?v=1773257982"},{"product_id":"c-tec-cfp708e-4-panel-8-zone-code-entry-conventional-fire-alarm-panel","title":"C-Tec CFP708E-4 Panel 8 Zone Code Entry Conventional Fire Alarm Panel","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eC-Tec CFP708E-4 CFP Economy 8 Zone Conventional Fire Alarm Panel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a versatile, cost-effective fire detection solution designed for larger installations requiring extended zone capacity. LPCB certified to EN54-2 and EN54-4 standards, this panel delivers comprehensive features at a competitive price point. Housed in an attractive flush or surface-mountable plastic enclosure, it provides eight detector zones and four conventional sounder circuits, making it ideal for schools, hotels, offices, industrial units, and multi-occupancy buildings. The intuitive interface features colour-coded buttons and combined keypad\/keyswitch entry for secure and straightforward operation. With four open-collector outputs and class change\/alert inputs, it offers flexibility while maintaining simplicity. Note that this economy version has limited engineering functions and is not compatible with expansion boards or repeaters, making it a straightforward, no-frills solution for basic fire alarm requirements where eight-zone coverage is needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features of C-Tec CFP708E-4 8 Zone Fire Alarm Panel\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLPCB Certified to EN54-2 \u0026amp; EN54-4:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Third-party certified by the Loss Prevention Certification Board for assured quality and compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eEight Detector Zones:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports up to 25 detectors per zone (or 32 combined detectors\/call points) with maximum 500m cable length per circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFour Conventional Sounder Circuits:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides up to 800mA total output current (4 x 200mA) for alarm devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIntuitive User Interface:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Colour-coded buttons and combined keypad\/keyswitch entry for straightforward user and engineer access.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIntegral Power Supply:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e EN54-4\/A2 compliant switch-mode PSU with support for up to 2 x 12V 3.2Ah VRLA batteries.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFour Open-Collector Outputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes Fire, Fault, Reset, and Remote outputs (30mA max sink current).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAuxiliary Inputs:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 'Class change' and 'Alert' inputs for external system control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFlush or Surface Mountable:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supplied in attractive plastic enclosure with no bezel required for clean finish.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLow Quiescent Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Energy-efficient standby operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eUK Manufactured:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built by C-TEC in the UK.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eExtended Zone Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Eight zones provide comprehensive coverage for larger premises.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFully Compatible:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Works seamlessly with C-TEC's ActiV range of conventional fire detectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC-Tec\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCFP708E-4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Zone Conventional Fire Alarm Panel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLPCB certified to EN54-2 \u0026amp; EN54-4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMains Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230V 50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDetector Zones\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Max 500m per circuit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDevices per Zone\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 detectors (or 32 combined detectors\/call points)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSounder Circuits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (Max 500m per circuit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSounder Output Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 x 200mA (800mA total)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEOL Resistor Value\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6800Ω (detector zone) \/ 6800Ω (sounder circuit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOpen Collector Outputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 (Fire, Fault, Reset, Remote)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuxiliary Inputs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass Change, Alert\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMax Battery Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 12V 3.2Ah VRLA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eExpansion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (not compatible with repeaters or relay cards)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e380mm x 235mm x 96mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlush or Surface mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-5°C to +40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer guarantee\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions (FAQs)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. How many devices can I connect across all eight zones?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eEach zone supports up to 25 detectors or 32 combined detectors and call points, allowing for a maximum of 200 detectors or 256 combined devices across all eight zones, providing substantial capacity for larger premises.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. What size premises is this 8-zone panel suitable for?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIdeal for medium to large buildings such as schools, hotels, industrial units, warehouses, offices, and multi-occupancy residential buildings requiring comprehensive zone coverage and reliable fire detection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. Can I add more sounder circuits if four are insufficient?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe panel has four dedicated sounder circuits with 800mA total capacity. For additional sounders, consider using higher-efficiency devices or consult manufacturer guidelines for load sharing across zones if permissible.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. Is this panel compatible with wireless detectors?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eNo, this is a conventional wired panel designed for use with C-TEC's ActiV range of wired conventional detectors. For wireless solutions, consider dedicated wireless fire alarm systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. What is the difference between this 8-zone economy panel and the standard version?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe economy panel has limited engineering functions and cannot be expanded with CFP repeaters, relay cards, or EN54-13 interface cards, making it a cost-effective standalone solution without expansion capabilities.\u003c\/span\u003e\u003c\/p\u003e","brand":"C-Tec","offers":[{"title":"Default Title","offer_id":57077373206910,"sku":null,"price":173.81,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0985\/3832\/4350\/files\/CFP704E-4_c25b99ef-205f-4ce6-8fdb-3f9fee3029ca.webp?v=1773258172"}],"url":"https:\/\/ssmelectric.co.uk\/collections\/c-tec.oembed","provider":"SSM ELECTRIC","version":"1.0","type":"link"}